PC20
DIGITAL MULTIMETER
γƒ‡γ‚Έγ‚Ώγƒ«γƒžγƒ«γƒγƒ‘γƒΌγ‚Ώ
取扱θͺ¬ζ˜Žζ›Έ
INSTRUCTION MANUAL
βˆ’β€¦β€¦28β€¦β€¦βˆ’βˆ’β€¦β€¦28β€¦β€¦βˆ’
CONTENTS
【 】1
SAFETY PRECAUTIONS:Before use, read the following safety precautions
γ€€ γ€€1-1 Explanation of Warning Symbols ..................................... 290
γ€€ γ€€1-2 Warning Instruction for safe use ...................................... 290
γ€€ γ€€1-3 Maximum Overload Protection Input ............................... 300
【 】2 APPLICATION AND FEATURES
γ€€ γ€€2-1 Application ....................................................................... 310
γ€€ γ€€2-2 Features ........................................................................... 310
【 】3 NAME OF COMPONENT UNITS
γ€€ γ€€3-1 Display ............................................................................. 310
γ€€ γ€€3-2 Multimeter, Test leads ..................................................... 320
【 】4 Description of Functions
γ€€ γ€€4-1 Switch and description .................................................... 330
γ€€ γ€€4-2 Connection with the personal computer ......................... 340
γ€€ γ€€4-3 Use of the AC adapter ..................................................... 350
【 】5 MEASUREMENT PROCEDURE
γ€€ γ€€5-1 Start-up Inspection .......................................................... 360
γ€€ γ€€5-2 Voltage Measurement ..................................................... 370
γ€€ γ€€5-3 Resistance Measurement ( ) ......................................... 38Ξ©0
γ€€ γ€€5-4 Testing Diode ( ) ........................................................... 38γ€€ 0
γ€€ γ€€5-5 Checking Continuity ( ) .................................................. 39γ€€0
γ€€ γ€€ 5-6 Capacity Measurement (γ€€) ........................................... 400
γ€€ ΞΌ ・ ・5-7 Current Measurement (γ€€A mA A) ............................. 410
γ€€γ€€5-7-1 Current Measurement ( A mA) ............................ 41γ€€ΞΌ ・ 0
γ€€γ€€5-7-2 Current Measurement (A) ......................................... 42γ€€0
γ€€5-8 How to use optional products ......................................... 43γ€€0
γ€€γ€€ γ€€5-8-1
Measurement using the AC flexible clamp sensor (CL3000)
... 430
γ€€ ο½₯γ€€ γ€€5-8-2 DC AC Clamp Probe (CL-22AD) ............................... 430
γ€€γ€€ γ€€5-8-3 DC Clamp Probe (CL33DC) ....................................... 440
γ€€γ€€ γ€€5-8-4 Temperature probe (T- 300PC) .................................. 440
【 】6 MAINTENANCE
γ€€ γ€€6-1 Maintenance and inspection ........................................... 450
γ€€ γ€€6-2 Calibration ........................................................................ 450
γ€€ γ€€6-3 How to Replace Battery and Fuse ................................... 460
γ€€ γ€€6-4 Cleaning and Storage ...................................................... 470
【 】7 SPECIFICATIONS
γ€€ γ€€7-1 Measurement Range and Accuracy................................. 480
γ€€ γ€€7-2 General Specifications ..................................................... 490
γ€€ γ€€7-3 Optional accessories General Specifications ................... 500
【 】8 After-Sales Service
γ€€ γ€€8-1 Warranty and Provision .................................................... 500
γ€€ γ€€8-2 Repair .............................................................................. 510
γ€€ γ€€8-3 SANWA web site ............................................................. 510
βˆ’β€¦β€¦29β€¦β€¦βˆ’βˆ’β€¦β€¦29β€¦β€¦βˆ’
【 】1
SAFETY PRECAUTIONS : Before use, read the following safety precautions
γ€€
This instruction manual explains how to use your multimeter PC20
safely. Before use, please read this manual thoroughly. After reading it,
keep it together with the product for reference to it when necessary.
γ€€Using the product in a manner not specified in this manual may
cause damage to the protection function of the product.
γ€€The instruction given under the heading "γ€€WARNING" "γ€€CAUTION"
must be followed to prevent accidental burn or electrical shock.
1-1 Explanation of Warning Symbols
γ€€The meaning of the symbols used in this manual and attached to
the product is as follows.
γ€€ : Very important instruction for safe use.
 ・The warning messages are intended to prevent accidents to
operating personnel such as burn and electrical shock.
 ・The caution messages are intended to prevent damage to
the instrument.
γ€€ : Dangerous voltage (Take care not to get an electric shock in
voltage measurement.)
γ€€ : : DC γ€œAC
Ξ©
: Resistance
γ€€: Buzzer : Diode :γ€œ γ€œ Ground
γ€€ : Plus : Minus γ€œ: Fuse
γ€€ : Double insulation
1-2 Warning Instruction for safe use
οΌ‹
γ€€To ensure that the meter is used safely, Be sure to observe
the instruction when using the instrument.
01. Never use meter on the electric circuit that exceed 6 kVA.
02. Pay special attention when measuring the voltage of AC 33
Vrms (46.7 Vpeak) or DC 70 V or more to avoid injury. Also
use insulating protective equipment as required.
03.
Never apply an input signals exceeding the maximum rating input value.
04. Never use meter for measuring the line connected with
equipment (i.e. motors) that generates induced or surge
voltage since it may exceed the maximum allowable voltage.
05.
Never use meter if the meter or test leads are damaged or broken.
06. Never use uncased meter.
WARNING
βˆ’
……
βˆ’β€¦β€¦30β€¦β€¦βˆ’βˆ’β€¦β€¦30β€¦β€¦βˆ’
0.5 A/250 V Fuse
protection
Maximum rating
input value
07.
Be sure to use a fuse of the specified rating or type. Never use a
substitute of the fuse or never make a short circuit of the fuse.
08. Always keep your fingers behind the finger guards on the
probe when making measurements.
09. Be sure to disconnect the test pins from the circuit when
changing the function or range.
10. Never use meter with wet hands or in a damp environment.
11. Never open tester case except when replacing batteries or
fuse. Do not attempt any alteration of original specifications.
12. To ensure safety and maintain accuracy, calibrate and check
the tester at least once a year.
13. Indoor use.
Function Input Maximum overload
protection value
1-3 Maximum Overload Protection Input
*The maximum rating input voltage in the time that connected to the personal
computer does to DC 300 V, AC 220 V (peak max. 310 V)
*The maximum rating input voltage in the time that used the AC adapter does to
DC 300 V, AC 220 V (peak max. 310 V)
DC /AC
γ€€ ・4 10 A
DCV
ACV
DC /AC
γ€€
400 A・4000ΞΌ
DC /AC
γ€€
40 400 mA・
Ξ©
/ / 
●
COM
( )βˆ’
:
:
:
V, Ξ©, ●
, ●
ΞΌA, mA
οΌˆοΌ‹οΌ‰
COMοΌˆβˆ’οΌ‰
:
4・10 A
DC, AC
γ€€10 A
*DC 1000 V
*AC 750 V
●
Voltage and current
input prohibited
DC,…AC
γ€€4000ΞΌA
DC, AC
γ€€400 mA
DC 1000 V AC 750 V,…
or peak max. 1000 V
DC 500 V AC 500 V,…
or peak max.700 V
12.5 A/250 V Fuse
protection
1. Correct maesurement may not be performed when using the
meter in the ferromagnetic / intense electric field such as
places near a transformer, a high-current circuit, and a radio.
2. The meter may malfunction or correct measurement may not
be performed when measuring special waveform such as that
of the inverter circuit.
CAUTION
βˆ’β€¦β€¦31β€¦β€¦βˆ’βˆ’β€¦β€¦31β€¦β€¦βˆ’
【 】2 APPLICATION AND FEATURES
2-1 Application
γ€€This instrument is portable multimeter designated for measurement
of weak current circuit.
2-2 Features
・4000 counts disply.
・With the capacity measurement function.
・The current function is the semi auto ranges.
・KB-USB20 interface (option)
・Main unit case and the circuit board is made of fire retarding
materials.
【 】3 NAME OF COMPONENT UNITS
3-1 Display
γ€” 〕Fig 1
Decimal point
Minus polarity display
for numeral data
Battery dischage
warning display
AC measurement display
DC mearsurement display
Relative
display
Numeral data display
Data hold displayChecking countinuity display
Measurement
unit display
Auto mode display
RS232C action
display
Testing diode
display
βˆ’β€¦β€¦32β€¦β€¦βˆ’βˆ’β€¦β€¦32β€¦β€¦βˆ’
21
3-2 Multimeter, Test leads
γ€” 〕Fig 2
Stand
Test lead (TL-21a)
Test lead
Fix
Holster
Display
Data hold
switch
Select
switch
Safety cover
4ο½₯10 A input
terminal
COM inputβˆ’
terminal
AC adaptor
input terminal
(With safety cap)
Range hold
switch
Power switch
and function
switch
V, Ξ© , , A, mA,● , ● ●μ
οΌ‹ input terminal
LED lamp
βˆ’β€¦β€¦33β€¦β€¦βˆ’βˆ’β€¦β€¦33β€¦β€¦βˆ’
【 】4 Description of Functions
4-1 Switch and description
β—‹ Power switch and function switch
Turn this switch to turn on and off the power and to select the
functions of V, Ξ©/● / ,● ● , ΞΌA, mA, A.
β—‹ Range hold switch
Pressing this switch once sets the manual mode and the range is
fixed. ("AUTO" on the display disappears)
Once the manual mode is set, the range moves each time this
switch is pressed. Checking the unit on the display and the place
of the decimal point, select a desired range. To return to the auto
mode, keep pressing this switch until "AUTO" on the display
appears.
β—‹ Data hold switch
When this switch is pressed, the data display at that time
continues ("DH" lights on the display). When the measuring input
changes, the display will not change.
When this switch is pressed again, the hold status is canceled you
can return to the measuring status. ("DH" on the display disappears.)
β—‹Select switch
When this
switch is
pressed ( ), β†’
the each
modes change
as follows.
… … →… γ€œβ€¦ →… … →… γ€œβ— ●
… … →… … →… … →…Ω●●Ω
(See 5-6 Capacity Measurement)
Vβ—οΌγ€œ
Ω/●/●
●
400・4000ΞΌA
●
οΌγ€œ
40・400 mA
●
οΌγ€œ
4・10 A β—οΌγ€œ
… … →… γ€œβ€¦ →… … →… γ€œβ— ●
Do not change over the function switch with a voltage applied
to the measuring terminals.
WARNING
●The PC20 does not have the auto power-off function.
When measurement is finished, be sure to return the function
switch to the OFF position.
βˆ’β€¦β€¦34β€¦β€¦βˆ’βˆ’β€¦β€¦34β€¦β€¦βˆ’
Maximum input voltage in the event that is connect with
computer is DC 300 V, AC 220 V (AC voltage is regulated by
rms value of sinusoidal wave. Peak max. 310 V)
WARNING
4-2 Connection with the personal computer
γ€€The multimeter is capable of DMM data communication using the
RS232C / USB interface. When the multimeter on which the optional
USB optical communication unit (KB-USB20) is mounted is connected
to a PC, the multimeter will output data to the PC. It is required to
purchase the optional PC link software (PC Link7) for this operation. For
details, refer to the Help for the optional PC link software (PC Link7).
<Connection of the multimeter and cable>
β‘ The stand that is in the reverse side of a multimeter is opened.
β‘‘Attach the box part of cable to the multimeter.
β‘’The opposite side of cable is connected to the computer.
β‘£Please use and please set up the stand when use it.
Function Data transfer speed Remarks
except following functions
Apporox. 0.5 s/times
50 nF max. Apporox. 1.4 s/times
γ€œ0500 nF Apporox. 1.7 s/times
γ€œ005 F Apporox. 2 s/timesΞΌ
γ€œ050 F Apporox. 5 s/timesΞΌ
γ€œ100 F Apporox. 9 s/timesΞΌ
Ξ©, ●Apporox. 0.7 s/times
γ€” 〕Fig 3
Cable
box
Nut thread
β‘ 
β‘£
 ● Data transfer speed to PC through KB-USB20 cable
γ€€γ€€Note:
γ€€γ€€DMM stops Data transfer to PC while range is shifting.
Data transfer speed
is changed for
each range when
capacitance
measurement.
β‘‘
βˆ’β€¦β€¦35β€¦β€¦βˆ’βˆ’β€¦β€¦35β€¦β€¦βˆ’
4-3 Use of the AC adapter (AD-71AC-2)
γ€” 〕Fig 4
<Connection of the AC adapter>
β‘ Pull up the safety cap from the AC adaptor input terminal of the
multimeter.
β‘‘The plug of the AC adapter into the terminal of the multimeter.
β‘’The AC adapter into the outlet for the home (AC 100 V).
β‘£Turning the function switch of the multimeter and turn on the
power supply.
●The incorporated battery and the AC adapter may be used together.
Note, however, when the PC20 is used with the AC adapter only,
the buzzer will not sound with such functions as the continuity
check ( ●).
●Insert the plug perpendicularly.
●Be sure to insert the plug to the position where the LED for
confirmation of AC adapter connection illuminates.
Outlet
AC adapter
1. Maximum input voltage in the event that is connect with AC
adapter is DC 300 V, AC 220 V (AC voltage is regulated by rms
value of sinusoidal wave. Peak max. 310 V)
2. Do not use the AC adapter other than designated devices.
3. Do not use the AC adapter other than AC 100 V for the home.
WARNING
β‘ 
β‘‘
β‘’
⑒’
β‘£
βˆ’β€¦β€¦36β€¦β€¦βˆ’βˆ’β€¦β€¦36β€¦β€¦βˆ’
β‘’Set the function
switch at / /Ξ©γ€€ γ€€
a nd sel ect th e
select switch atγ€€ .
【 】5 MEASUREMENT PROCEDURE
5-1 Start-up Inspection
1. Never use meter if the meter or test leads are damaged or
broken.
2. Make sure that the test leads are not cut or otherwise damaged.
WARNING
No problem.
Start measurement.
β‘£Short the red and
black test pins.
β‘ 
Connect the test lead
of black plug to the
COM βˆ’ terminal.
β‘‘
Connect the test
lead of red plug to
the οΌ‹ terminal.
START
Main unit and
test leads
damaged?
Display shows
000.0 001.0?γ€œ
Buzzer beeps?
Damaged
No damage
No
Yes
Sto p u sing it and
have it repaired.
Check continuity of
test leads.
γ€” 〕Fig 5
β‘ 
β‘’
β‘‘
β‘£
βˆ’β€¦β€¦37β€¦β€¦βˆ’βˆ’β€¦β€¦37β€¦β€¦βˆ’
1) Applications
DCV : Measures batteries and DC circuits.
: Measures sine-wave AC voltage as lighting voltages. ACV
2) Measuring ranges
DCV : 400 mV 1000 V (5 ranges) γ€œ
: 750 V (4 ranges) ACV 4 V γ€œ
3) Measurement procedure (See Fig 6 or 7, page 10)
β‘ Connect the black plug of the test lead to the COM input βˆ’
terminal and the red plug to the input terminal. οΌ‹
β‘‘Set the function switch at "V / " function. γ€œ
β‘’Select the select switch at " " (DC) or " " (AC).γ€€ γ€œ
β‘£Apply the black test pin to the negative potential side of the circuit
to measure and the red test pin to the positive potential side.
β‘€Read the value on the display.
β‘₯After measurement, remove the red and black test pins from
the circuit measured.
⑦Turn the function switch to the position of OFF.
●In the AC 4 V range, a figure of about 3~9 counts will stay on even
if no input signal is present. But it is not malfunction.
●In the manual mode of the ACV function, the PC20 can be set to
the 40 0 mV range and shows an approximate value. But its
accuracy is not guaranteed.
●Since this instrument employs the means value system for its
AC voltage measurement circuit, AC waveform other than sine
wave may cause error.
5-2
Voltage Measurement Maximum rating input value 1000 VDC or 750 VAC
1. Never apply an input signals exceeding the maximum rating
input value.
2. Be sure to disconnect the test pins from the circuit when
changing the function.
3. Always keep your fingers behind the finger guards on the probe
when making measurements.
WARNING
βˆ’β€¦β€¦38β€¦β€¦βˆ’βˆ’β€¦β€¦38β€¦β€¦βˆ’
5-4 Testing Diode ( )
Never apply voltage to the input terminals.
WARNING
5-3 Resistance Measurement ( )Ξ©
Never apply voltage to the input terminals.
WARNING
1) Application
Resistance of resistors and circuits are measured.
2) Measuring ranges
400 40 M (6 ranges)Ξ©γ€œΞ©
3) Measurement procedure (See Fig 8, page 11)
β‘ Connect the black plug of the test lead to the COM βˆ’ input
terminal and the red plug to the input terminal. οΌ‹
β‘‘Set the function switch at " / / " function.Ξ©γ€€ γ€€
β‘’Select the select switch at " " (M ). Ξ© Ξ©
β‘£Apply the black and red test pin to measured circuit.
β‘€Read the value on the display.
β‘₯After measurement, remove the red and black test pins from the
circuit measured.
⑦Turn the function switch to the position of OFF.
●If measurement is likely to be influenced by noise, shield the object
to measure with negative potential (test lead black).
●If a test pin is touched by a finger during measurement,
measurement will be influenced by the resistance in the human
body to result in measurement error.
●The input terminals release voltage is about 0.4 V.
●The reading may vary because of external inductance when
measuring high resistance value.
1) Application
The quality of diodes is tested.
2) Measurement procedure (See Fig 9, page 12)
β‘ Connect the black plug of the test lead to the COM input βˆ’
terminal and the red plug to the input terminal. οΌ‹
β‘‘Set the function switch at "Ξ©/ / γ€€ γ€€" function.
βˆ’β€¦β€¦40β€¦β€¦βˆ’βˆ’β€¦β€¦40β€¦β€¦βˆ’
●When a resistance value is in a range of 10 , noise will γ€œ120 Ξ©
be mixed in the buzzer sound. But it is not malfunction.
5-6 Capacity Measurement ( )
1. Never apply voltage to the input terminals.
2. Be sure to discharge the capacitor prior to measurement.
WARNING
1) Application
Measures capacitance of capacity.
2) Measuring ranges
50 nF* F (5 ranges) 1000 nF 1 Fγ€œ100 ΞΌ γ€€γ€€γ€€οΌŠ = ΞΌ
3) Measurement procedure (See Fig 11, page 14)
β‘ Connect the black plug of the test lead to the COM βˆ’ input
terminal and the red test lead to the input terminal. οΌ‹
β‘‘Set the function switch at " " function.γ€€
β‘’Press the SELECT switch to make the display show 00.00 nF.
(The "REL" mark illuminates in the upper right area of the display.)
[CAUTION] If the SELECT switch is pressed immediately after the
function switch has been set at " ", the display may be locked, making
measurement impossible. Should this be the case, set the function
switch to a different range once, then back to " " and wait for more
than 2 seconds before pressing the SELECT switch again.
β‘£Apply the red and black test pins to capacitor.
β‘€Read the value on the display.
β‘₯After measurement, release the red and black test pins from the
object measured.
⑦Turn the function switch to the position of OFF.
● γ€€ The " " function can be set to the auto range, but not to the
manual range.
●In 5 nF and 50 nF ranges, large value is left, especially when
disconnecting measuring terminals. This is not malfuction.
●For measurement of 100 nF (0.1 F) or below, the display will ΞΌ
not stabilize due to the influence of ambient noise and floating
capacity. It is therefore recommended that an object to measure
(capacitor) be directly connected between the ( οΌ‹ βˆ’) and ( )
measuring terminals of the PC20.
●As the capacitance increases, the measuring time becomes longer.
Example: 2 to 4 seconds at 10 ΞΌFγ€€γ€€γ€€5 to 8 seconds at 50ΞΌF
Example: 13 to 16 seconds at 100ΞΌF
βˆ’β€¦β€¦42β€¦β€¦βˆ’βˆ’β€¦β€¦42β€¦β€¦βˆ’
β‘€Read the value on the display.
β‘₯After measurement, remove the red and black test pins from
the circuit measured.
⑦Turn the function switch to the position of OFF.
●If the display will not change when an input signal is applied
(measurement is not possible), a probable cause is a blown fuse.
●Since this instrument employs the means value system for its
AC voltage measurement circuit, AC waveform other than sine
wave may cause error.
5-7-2
Current Measurement (A) Maximum rating input value DC/AC 10 A
1. Never apply voltage to the input terminals.
2. Finish measurement within 45 seconds to prevent heat
generation.
3. Provide intervals 2 minutes or longer between measurements
to prevent heat generation. (Continuous measurement:max 5 A)
4. Perform measurement with the leads kept straight to prevent
overheat.
WARNING
1) Applications
Current in DC and AC circuit is measured.
2) Measuring ranges
DCA: 4 10 A (2 ranges), ACA: 4 10 A (2 ranges)ο½₯ ο½₯
3) Measurement procedure (See Fig 14, page 17)
β‘ Slide the safety cover of the PC20 to the left and insert the red
plug of the test leads to the 4 10 A measuring terminal and the ο½₯
black plug to the COM ( ) terminal. βˆ’
β‘‘Set the function switch at "4 / " function.ο½₯10 Aγ€€ γ€œ
β‘’Select the select switch at " " (DC) or " " (AC). γ€€ γ€œ
β‘£Apply the black test pin to the negative potential side of the
circuit to measure and the red test pin to the positive potential
side.
β‘€Read the value on the display.
β‘₯After measurement, remove the red and black test pins from
the circuit measured.
⑦Turn the function switch to the position of OFF.
βˆ’β€¦β€¦43β€¦β€¦βˆ’βˆ’β€¦β€¦43β€¦β€¦βˆ’
●If the display will not change when an input signal is applied
(measurement is not possible), a probable cause is a blown fuse.
●Since this instrument employs the means value system for its
AC voltage measurement circuit, AC waveform other than sine
wave may cause error.
5-8 How to use optional products
Never apply an input signals exceeding the maximum rating
input value of optional products.
WARNING
5-8-1 Measurement using the AC flexible clamp sensor (CL3000)
Maximum measurable current: AC 3000 A
1) Measurement target
γ€€AC sine wave of 50-60 Hz, such as the current consumption of
a home appliance or power supply equipment.
2) Measurement ranges
γ€€Three ranges of AC 30 A, AC 300 A and AC 3000 A.
3) Measurement procedure
β‘ Connect the red plug of the current probe to the + measurement
terminal and the black plug to the COM (βˆ’) terminal.
β‘‘Set the function switch of this instrument (PC20) to β€œACV”.
β‘’Set the range hold button to the 6 V range.
β‘£
S
et the range setting knob of the current probe to the 30 A, 300 A or
3000 A range.
β‘€Clamp the measurement target conductor with the current probe.
β‘₯If the range of the current probe is 30 A, read the displayed value
by mult iply i ng i t by 10 .
Similarly, multiply it by 100
with the 300 A range and
multiply by 1000 with the
3000 A. The uni t of the
obtained value is A (ampere).
⑦After the measurement,
disconnect the current probe
from t he measur e m ent
target conductor.
⑧Set the power switches of
this instrument (PC20) and
probe (CL3000) to OFF.
ACV
OFFOFF
β‘₯
β‘‘
⑧
β‘€
β‘’
β‘ 
β‘£
γ€” 〕Fig 7


Product specificaties

Merk: Sanwa
Categorie: Multimeter
Model: PC20

Heb je hulp nodig?

Als je hulp nodig hebt met Sanwa PC20 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Multimeter Sanwa

Sanwa

Sanwa CD5001 Handleiding

7 December 2024
Sanwa

Sanwa SP21 Handleiding

6 Januari 2024
Sanwa

Sanwa VS-100 Handleiding

6 Januari 2024
Sanwa

Sanwa SP-18D Handleiding

5 Januari 2024
Sanwa

Sanwa EM7000 Handleiding

5 Januari 2024
Sanwa

Sanwa AP33 Handleiding

5 Januari 2024
Sanwa

Sanwa CX506a Handleiding

5 Januari 2024
Sanwa

Sanwa CD732 Handleiding

27 December 2023

Handleiding Multimeter

Nieuwste handleidingen voor Multimeter