Samsung AM040KXMDEH Handleiding

Samsung Airco AM040KXMDEH

Lees hieronder de ๐Ÿ“– handleiding in het Nederlandse voor Samsung AM040KXMDEH (17 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 19 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/17
3
ENGLISH
WARNING โ€ข Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION โ€ข Hazards or unsafe practices that may result in minor personal injury (to installer/user) or property
damage.
SEVERE WARNING SIGNS
Consult quali๎˜Ÿed installer or dealer for installation.
๎˜ƒ๎™˜ When installation is done by unquali๎˜Ÿed person, problems such as water leakage, electric shock or ๎˜Ÿre may occur.
Installation work must be done properly according to this installation manual.
๎˜ƒ๎™˜ When installation is not done properly, it may cause water leakage, electric shock or ๎˜Ÿre.
When installing the unit in a small room, take measure to keep the refrigerant concentration from exceeding allowable
safety limits in case of refrigerant leakage. Consult the dealer for precautionary measure before the installation.
๎˜ƒ๎™˜ When refrigerant leaks and exceed dangerous concentration level, it may cause su๎˜ocation accidents.
If any gas or impurities, except R-410A refrigerant, come into the refrigerant pipe, serious problem may occur and it may
cause injury.
Use the supplied accessories, speci๎˜Ÿed components and tools for the installation.
๎˜ƒ๎™˜ Do not use the pipe and the installation product used for the R-22 refrigerant.
๎˜ƒ๎™˜ Failure to use the speci๎˜Ÿed components can cause product fall down, water leakage, electrical shock, and ๎˜Ÿre. (The pipe
and ๎˜žare components used for R-22 refrigerant must not be used)
Install the outdoor unit on a hard and even place that can support its weight.
๎˜ƒ๎™˜ If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
Safety precautions
Please follow the following safety information for safety of the installer and the user.
๎˜ž DVM S ECO air conditioner uses R-410A refrigerant.
โ€ข When using R-410A, moisture or foreign substances may a๎˜ect the performance and reliability of the product.
Safety precautions must be obeyed when installing the refrigerant pipe.
โ€ข The designed maximum pressure of the system is 4.1MPa and therefore select appropriate material and thickness
according to the regulations.
โ€ข R-410A is a quasi-azeotrope of two refrigerants and it has to be charged in liquid phase when ๎˜Ÿlling the refrigerant.
(If you charge vapor refrigerant, it may change the blend of the refrigerant and cause product malfunction.)
๎˜ž You must connect the indoor units for R-410A refrigerant. Refer to product catalog to ๎˜Ÿnd out the models names
for connectable indoor units. (If you connect the indoor units that are not designed for R-410A, it cannot operated
normally.)
๎˜ž After completing the installation and trial operation, explain to the user how to use and maintain the product. Also,
hand over this installation manual so that it can be stored by the user.
๎˜ž Manufacturer is not responsible for the incidents occurred by improper installation. Installer is responsible for any
installation related claims from the user occurred by neglecting warnings and cautions stated in this manual. (Installer
will be responsible for any service charges that may occur)
๎˜ž Generally, system air conditioners should not be relocated after installation. But when it has to be relocated for
inevitable reasons, please contact Samsungโ€™s quali๎˜Ÿed dealers for system air conditioners.
13
ENGLISH
Case 2: Obstacle on exhausting side is lower than the unit.(regardless of the height of obstacle on suction side)
๎˜ž The upper part of the outdoor unit is not blocked
โ‘  โ‘กWhen installing 1 outdoor unit When parallel installing more than 2 outdoor units(*1)
1500 or more 300 or more
1500 or more
300 or more
300 or more1500 or more
600 or more 600 or more
1500 or more
300 or more
โ–ฒ
The frontside block can not be higher than the outdoor unit. If the frontside block is higher than the outdoor unit,
arrange the outdoor unit higher than the frontside block.
(*1) When installing outdoor units paralleled, more than 600mm gap shall be left.
(C) When air inlet and air outlet of the outdoor unit are blocked
Case 1: Obstacle on exhausting side is higher than the unit.(regardless of the height of obstacle on suction side)
๎˜ž The upper part of the outdoor unit is not blocked
โ‘  โ‘กWhen installing 1 outdoor unit When parallel installing more than 2 outdoor units(*1)
1500 or more 300 or more
1500 or more
300 or more
300 or more1500 or more
600 or more 600 or more
1500 or more
300 or more
โ–ฒ
The backside block can not be higher than the outdoor unit. If the backside block is higher than the outdoor unit,
arrange the outdoor unit higher than the backside block.
Unit: mm
When front and rear side of the outdoor unit is toward the wall
1500 or more 600 or more 3000 or more 3000 or more3000 or more


Product specificaties

Merk: Samsung
Categorie: Airco
Model: AM040KXMDEH

Heb je hulp nodig?

Als je hulp nodig hebt met Samsung AM040KXMDEH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Samsung

Handleiding Airco

Nieuwste handleidingen voor Airco