Profilo ATS6S250 Handleiding

Profilo Afzuigkap ATS6S250

Lees hieronder de 📖 handleiding in het Nederlandse voor Profilo ATS6S250 (12 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 43 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
[en] Instruction manual
Extractor hood ATS6S220, ATS6S260,
ATS6S250
2
Ú Table of contents
[en]Instruction manual
Important safety information .................................................... 2
Environmental protection ......................................................... 4
Saving energy......................................................................................4
Environmentally-friendly disposal.....................................................4
Operating modes ....................................................................... 4
Exhaust air mode................................................................................4
Circulating-air mode ...........................................................................4
Operating the appliance............................................................ 5
Filter drawer .........................................................................................5
Lighting .................................................................................................5
Cleaning and maintenance ....................................................... 5
Trouble shooting........................................................................ 7
After-sales service ..................................................................... 7
Accessories for circulated air mode ........................................ 8
: Important safety information
Read these instructions carefully. Only then
will you be able to operate your appliance
safely and correctly. Retain the instruction
manual and installation instructions for
future use or for subsequent owners.
The appliance can only be used safely if it
is correctly installed according to the safety
instructions. The installer is responsible for
ensuring that the appliance works perfectly
at its installation location.
This appliance is intended for domestic use
and the household environment only. The
appliance is not intended for use outside.
Do not leave the appliance unattended
during operation. The manufacturer is not
liable for damage which is caused by
improper use or incorrect operation.
This appliance is intended for use up to a
maximum height of 2000 metres above sea
level.
This appliance may be used by children
over the age of 8 years old and by persons
with reduced physical, sensory or mental
capabilities or by persons with a lack of
experience or knowledge if they are
supervised or are instructed by a person
responsible for their safety how to use the
appliance safely and have understood the
associated hazards.
Children must not play with, on, or around
the appliance. Children must not clean the
appliance or carry out general maintenance
unless they are at least 8 years old and are
being supervised.
Keep children below the age of 8 years old
at a safe distance from the appliance and
power cable.
Check the appliance for damage after
unpacking it. Do not connect the appliance
if it has been damaged in transport.
Only a licensed professional may connect
appliances without plugs. Damage caused
by incorrect connection is not covered
under warranty.
Danger of suffocation!
Packaging material is dangerous to
children. Never allow children to play with
packaging material.
Danger of death!
Risk of poisoning from flue gases that are
drawn back in.
Always ensure adequate fresh air in the
room if the appliance is being operated in
exhaust air mode at the same time as room
air-dependent heat-producing appliance is
being operated.
Room air-dependent heat-producing
appliances (e.g. gas, oil, wood or coal-
operated heaters, continuous flow heaters
or water heaters) obtain combustion air
from the room in which they are installed
and discharge the exhaust gases into the
open air through an exhaust gas system
(e.g. a chimney).
In combination with an activated vapour
extractor hood, room air is extracted from
the kitchen and neighbouring rooms - a
partial vacuum is produced if not enough
fresh air is supplied. Toxic gases from the
chimney or the extraction shaft are sucked
back into the living space.
â– Adequate incoming air must therefore
always be ensured.
â– An incoming/exhaust air wall box alone
will not ensure compliance with the limit.
Safe operation is possible only when the
partial vacuum in the place where the heat-
producing appliance is installed does not
exceed 4 Pa (0.04 mbar).
3
This can be achieved when the air needed
for combustion is able to enter through
openings that cannot be sealed, for
example in doors, windows, incoming/
exhaust air wall boxes or by other technical
means.
In any case, consult your responsible
Master Chimney Sweep. He is able to
assess the house's entire ventilation setup
and will suggest the suitable ventilation
measures to you.
Unrestricted operation is possible if the
vapour extractor hood is operated
exclusively in the circulating-air mode.
Risk of fire!
â– Grease deposits in the grease filter may
catch fire.
Clean the grease filter at least every
2 months.
Never operate the appliance without the
grease filter.
Risk of fire!
â– Grease deposits in the grease filter may
catch fire. Never work with naked flames
close to the appliance (e.g. flambéing). Do
not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-
removable cover is available. There must
be no flying sparks.
Risk of fire!
â– Hot oil and fat can ignite very quickly.
Never leave hot fat or oil unattended.
Never use water to put out burning oil or
fat. Switch off the hotplate. Extinguish
flames carefully using a lid, fire blanket or
something similar.
Risk of fire!
â– When gas burners are in operation without
any cookware placed on them, they can
build up a lot of heat. A ventilation
appliance installed above the cooker may
become damaged or catch fire. Only
operate the gas burners with cookware on
them.
Risk of fire!
â– Operating several gas burners at the
same time gives rise to a great deal of
heat. A ventilation appliance installed
above the cooker may become damaged
or catch fire. Never operate two gas
burners simultaneously on the highest
flame for longer than 15 minutes. One
large burner of more than 5 kW (wok) is
equivalent to the power of two gas
burners.
Risk of burns!
The accessible parts become very hot when
in operation. Never touch hot parts. Keep
children at a safe distance.
Risk of injury!
â– Components inside the appliance may
have sharp edges. Wear protective gloves.
Risk of injury!
â– Items placed on the appliance may fall
down. Do not place any objects on the
appliance.
Risk of electric shock!
â– A defective appliance may cause electric
shock. Never switch on a defective
appliance. Unplug the appliance from the
mains or switch off the circuit breaker in
the fuse box. Contact the after-sales
service.
Risk of electric shock!
â– Incorrect repairs are dangerous. Repairs
may only be carried out and damaged
power cables replaced by one of our
trained after-sales technicians. If the
appliance is defective, unplug the
appliance from the mains or switch off the
circuit breaker in the fuse box. Contact the
after-sales service.
Risk of electric shock!
â– Do not use any high-pressure cleaners or
steam cleaners, which can result in an
electric shock.
Causes of damage
Caution!
Risk of damage due to corrosion. Always switch on the
appliance while cooking to avoid condensation. Condensate
can produce corrosion damage.
Always replace faulty bulbs to prevent the remaining bulbs from
overloading.
Risk of damage due to ingress of humidity into the electronic
circuitry. Never clean operator controls with a wet cloth.
Surface damage due to incorrect cleaning. Clean stainless
steel surfaces in the direction of the grain only. Do not use any
stainless steel cleaners for operator controls.
Surface damage due to strong or abrasive cleaning agents.
Never use strong and abrasive cleaning agents.
Risk of damage from returning condensate. Install the exhaust
duct in such a way that it falls away from the appliance slightly
(1° slope).


Product specificaties

Merk: Profilo
Categorie: Afzuigkap
Model: ATS6S250
Soort bediening: Knoppen
Kleur van het product: Zilver
Ingebouwd display: Nee
Gewicht: 7000 g
Breedte: 600 mm
Diepte: 280 mm
Hoogte: 175 mm
Netbelasting: 181 W
Snoerlengte: 1.3 m
Geluidsniveau: 62 dB
Energie-efficiëntieklasse: E
Jaarlijks energieverbruik: 116 kWu
Gewicht verpakking: 8000 g
Diepte verpakking: 365 mm
Soort: Muurmontage
Motor vermogen: - W
Uitlaat aansluiting diameter: 150 mm
Illuminance: 113 Lux
Motor inbegrepen: Ja
Aantal motors: 1
Maximale afzuigcapaciteit: 300 m³/uur
Afzuigmethode: Afvoerend/recirculerend
Fluid dynamic efficiency class: F
Verlichtingefficiëntieklasse: G
Vetfilterefficiëntieklasse: C
Aantal lampen: 2 gloeilamp(en)
Type lamp: Halogeen
Soort vetfilter: Aluminium
Wasbaar filter: Ja
Vermogen lamp: 56 W
Verwijderbare filter: Ja
Aantal filters: 2 stuk(s)
Aantal snelheden: 3
Vaatwasserbestendig filter: Ja
Certificering: CE
AC-ingangsspanning: 220-240 V
AC-ingangsfrequentie: 50 Hz

Heb je hulp nodig?

Als je hulp nodig hebt met Profilo ATS6S250 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Profilo

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap