PCE Instruments PCE-PHD 1 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor PCE Instruments PCE-PHD 1 (22 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/22
Manual
PH EC- -O2 pH meter PCE-PHD 1
Version 2.0
20.01.2016
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
Manual
2
Table of contents
1 Introduction ............................................................................................................. 3
1.1 Delivery contents ........................................................................................................................ 3
2 Safety information ................................................................................................... 3
2.1 Warning symbols ........................................................................................................................ 3
2.2 Safety precautions ...................................................................................................................... 3
3 Specifications .......................................................................................................... 4
4 Device description .................................................................................................. 7
5 Instructions .............................................................................................................. 8
5.1 Mode selection 8...........................................................................................................................
5.2 pH / mV measurement ................................................................................................................ 8
5.3 mV measurement ....................................................................................................................... 9
5.4 pH calibration .............................................................................................................................. 9
5.5 Conductivity measurement ....................................................................................................... 10
5.6 TDS measurement ................................................................................................................... 11
5.7 Conductivity calibration ............................................................................................................. 11
5.8 Salt content measurement ........................................................................................................ 11
5.9 Calibration of the salt content measurement ............................................................................ 12
5.10 Dissolved oxygen measurement .............................................................................................. 12
5.11 Atmospheric oxygen content measurement ............................................................................. 12
5.12 Calibration of the atmospheric oxygen content measurement ................................................. 13
5.13 Maintenance of the oxygen probe ............................................................................................ 13
5.14 Other functions ......................................................................................................................... 14
5.15 Datalogger ................................................................................................................................ 14
5.16 SD card structure ...................................................................................................................... 16
5.17 16 To save the SD card data on the computer (EXCEL software) ................................................
5.18 Further settings ......................................................................................................................... 17
5.19 RS232 interface ........................................................................................................................ 19
6 Maintenance and cleaning .................................................................................... 21
6.1 Battery replacement ................................................................................................................. 21
6.2 System reset ............................................................................................................................. 21
7 Disposal ................................................................................................................. 21
8 Contact ................................................................................................................... 22
Manual
3
1 Introduction
Thank you for purchasing a PCE-PHD 1 meter from PCE Instruments.
This portable pH meter can test the pH value of water, as well as conductivity, temperature and the
oxygen content. The meter is delivered with an integrated conductivity sensor and a pH sensor. You can
store all values on an SD card (up to 16 GB) in Excel format and also transfer them to a computer using
the RS-232 interface. A three-point calibration automatic temperature compensation guarantee a and
high degree of accuracy even with variable temperature measurements.
1.1 Delivery contents
1 x pH meter PCE-PHD 1, 1 x pH electrode, 1 x conductivity electrode, 1 x SD memory card, 6 x batteries
and user's manual
2 Safety notes
2.1 Warning symbols
General warning. Urgently consult the documentation.
Operating voltage is under its set point. Change batteries to avoid faulty measurements.
2.2 Safety precautions
Please read this user's manual carefully and completely before you use it for the first time. The device
may only be used by qualified personnel. There is no warranty of damage caused by non-observance of
the manual.
- Non-observance of the manual may be dangerous for the user or cause destruction of the device.
- The device may only be used approved temperature and humidity range. Direct exposure to sunlight in
or moisture (e. g. wet hands) must be avoided.
-
The opening the case should only be done by qualified personnel of PCE Instruments. of
- The instrument should never be placed with the user interface facing an object ( keyboard side on a e.g.
table ).
- You must not make any technical changes the device. to
- The appliance should only be cleaned with a damp cloth / use only -neutral cleaner, no abrasives or pH
solvents.
- The meter may only be used with the accessories offered by PCE Instruments or equivalent.
- Before using the device, check the case and the test leads for visible damage. If you find damage, do
not use the device.
- The appliance must not be used in potentially explosive atmospheres.
- If the battery is flat (which is indicated by the battery indicator), do not use the meter as faulty
measurements can cause life-threatening situations. You can carry on after replacing the batteries.
- Check for proper functionality by measuring a known quantity.
- It is very urgent that you do not exceed the set points stated in the specifications.
- Before opening the case in order to replace the battery or fuse, remove all test leads to avoid an electric
shock.
- When you do not use the device for a long time, remove the batteries to avoid damage caused by
leakage of the battery.
This user's manual is published PCE Instruments without any guarantee. by
We expressly refer to our general guarantee terms, they can be found in our general terms of business.
If you have any questions please ntact PCE Instruments. co


Product specificaties

Merk: PCE Instruments
Categorie: Meetapparatuur
Model: PCE-PHD 1

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-PHD 1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur PCE Instruments

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur