HVAC Meter
PCE-LCT 1
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@pce-instruments.com
TABLE OF CONTENTS
.Features…………………………………………………………………………1Ⅰ
.Panel Description………………………………………………………………2Ⅱ
.Operation lnstructions…………………………………………………………4Ⅲ
A.AC Leakage current Measurements………………………………………4
1.Leakage current Flowing into Ground Conductor……………………4
2.Out of Balance Leakage current…………………………………………5
3.Using the 50/60and Wide Selector………………………………………6
B.AC Load Current Measurement……………………………………………7
C.AC Voltage Measurements…………………………………………………7
D.Resistance and continuity Measurement…………………………………8
E. Relative Reading Measurements…………………………………………8
F. Holding the LCD Reading……………………………………………………8
G.Finding the MAX/MIN Value…………………………………………………8
H.Auto-Power-Off………………………………………………………………9
IV.Specifications……………………………………………………………………9
V. Battery Replacement…………………………………………………………10
.Featuresâ… 
1.Accurate AC digital clamp meter for leakage current measurement.
2.10μ
μ
μ
μμA high resolution on 40mA range.
3.Shield transformer jaws to minimizs the effect of external stray
magnetic field.
4.Large jaw with 30 mm diameter.
5.Five Ranges (40mA, 400mA,4A,40A,100A)for all application.
6.A filter circuit is designed to eliminate the effect of high frequency
noise and harmonics by setting the frequency selector switch at the
50/60 Hz position for AC current measurement.
7.Large 3 3/4 digits LCD
2
8.Fast bargraph display (20 times/sec.)for transient observation.
9.Continuity and frequency measurements.
10.Max/Min and Data Hold functions.
11.Relative Measurement.
12.600V overload protection for ohm measurement.
13.Easy single rotary switch for any function selection.
.Panel Descriptionâ…¡
1.Transformer Jaw
This is used to pick up current signal.To measure DC/AC current,
conductor must be enclosed by the jaw.
2.Transformer Trigger
This is used to open the jaw.
3.Function Selector Switch
This is used to select the function user desired, such as ACV ,ACA,ohm
and continuity.
4.Frequency Selection Switch
At 50/60Hz position,only the low frequency signal is measured.At wide