PCE Instruments PCE-IT 120 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor PCE Instruments PCE-IT 120 (10 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 6 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
© PCE Instruments
PCE-IT 120 Insulation Test er
User Manual
User manuals in various languages (français,
italiano, español, português, nederlands, türk, polski,
русский,
) can be found by using our
product search on: www.pce-instruments.com
Last change: 15 August 2019
v1.0
English
© PCE Instruments
Contents
1 Safety notes ........................................................................................... 1
2 Delivery contents .................................................................................. 3
3 Specications ........................................................................................ 3
4 Short product description .................................................................... 4
5 Functions ............................................................................................... 5
5.1 [ON/TEST] key (on/o function) ........................................................................................ 5
5.2 Battery test ....................................................................................................................... 5
5.3 Voltmeter 5..........................................................................................................................
5.4 Auto Hold ......................................................................................................................... 5
5.5 250 V, 500 V, 1 kV insulation resistance measurement .................................................... 5
5.6 [ON/TEST] key (measuring function) ................................................................................ 5
5.7 EnerSave function ............................................................................................................ 6
5.8 [LOW ] key for continuity tests ....................................................................................... 6
5.9 [LOW Ω] key for Auto Zero ............................................................................................... 6
5.10 [1000V] key for power o (Auto Power O) 6......................................................................
5.11 Automatic discharge after an insulation measurement ...................................................... 6
6 Safety checks before the measurement ............................................. 6
7 Changing the fuse ................................................................................. 6
8 Further information ............................................................................... 7
9 . 7 Contact ................................................................................................
10 Disposal ................................................................................................. 7
© PCE Instruments
1
1 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The
device may only be used by qualied personnel and repaired by PCE Instruments personnel.
Damage or injuries caused by non-observance of the manual are excluded from our liability and
not covered by our warranty.
The device must only be used as described in this instruction manual. If used otherwise,
this can cause dangerous situations for the user and damage to the meter.
The instrument may only be used if the environmental conditions (temperature, relative
humidity, …) are within the ranges stated in the technical specifications. Do not expose
the device to extreme temperatures, direct sunlight, extreme humidity or moisture.
Do not expose the device to shocks or strong vibrations.
The case should only be opened by qualied PCE Instruments personnel.
Never use the instrument when your hands are wet.
You must not make any technical changes to the device.
The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner,
no abrasives or solvents.
The device must only be used with accessories from PCE Instruments or equivalent.
Before each use, inspect the case for visible damage. If any damage (crack in the case,
dama OLED, etc.) is visible or an insulation damage at the test leads (bare wires) ged
is apparent, do not use the device and the test leads.
Do not use the instrument in explosive atmospheres.
The measurement range as stated in the specications must not be exceeded under
any circumstances.
Non-observance of the safety notes can cause damage to the device and injuries to
the user.
Measurements with the insulation tester may only be made by qualied sta and in line
with the requirements described in the manual. Damage caused by improper use of the
meter, non-observance of general safety regulations or of the instructions in the manual
are not covered by the warranty.
Only replace defective fuses by an equal equivalent.
The insulation tester fulls the general safety regulations. However, these do not protect
the user from improper use of the meter and the resulting hazards. When measuring
voltages above 24 V, there is a risk of electric shock. Therefore, high-voltage
measurements should be made very carefully and not without observing the applicable
safety regulations. Non-observance of the safety notes can be life-threatening!
The parts of the manual that contain information and warnings about possible hazards
related with certain measuring operations must be observed.
When connecting the meter to a live circuit or line, a pulsating alarm tone will sound.
Immediately disconnect the insulation tester from the circuit or line when you hear the
alarm sound. Additionally, a warning indicator will be displayed on the OLED.
Operating conditions
Indoor use only (not suitable for outdoor use)
Pollution degree 2
Max. elevation: 2000 m
Max. air humidity: 80 % RH
Operating temperature range: 0 ... 40 °C


Product specificaties

Merk: PCE Instruments
Categorie: Meetapparatuur
Model: PCE-IT 120

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-IT 120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur PCE Instruments

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur