PCE Instruments PCE-DPD-U Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor PCE Instruments PCE-DPD-U (28 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 5 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
PCE-DPD-U
Mulsignal panel meter
Mulsignal digital panel meter, congurable to work as AC and DC voltmeter (up to 600 Vac / dc), AC and DC
ammeter (up to 5 Aac / dc), accepts process signals (mA, Vdc), thermocouples, resisve temperature probes
(Pt, Ni, PTC and NTC), resistances, potenometers and frequency. Congurable. Standard 96 x 48 mm size
(1/8 DIN). Scalable reading with 4 digits (9999 / -1999). ‘Fast access’ funcon to alarm setpoints, ‘external
control’ to acvate predened funcons, ‘Eco’ mode for low consumpon, selectable dual scaling, 5 levels
of congurable brightness. Single universal power supply 18 to 265 Vac/dc. Oponal modules for output
and control (relays, analog output, Modbus RTU).
User’s Manual
PANEL METERS
4822r06
www.pce-instruments.com
2
1. Panel meter PCE-DPD-U
Mulsignal 96x 48 mm panel meter   
Mulsignal digital panel meter in 96 x 48 mm size (1/8 DIN). Accepts
AC and DC voltage signals from mV up to 600 V and currents up to
5 A (AC measures in True RMS), process signals (mA and Vdc) with
excitaon voltage included, thermocouples K, J, E, N, L, R, S, B, T and
C, resisve temperature probes (Pt100, Pt500, Pt1000, Ni100, Ni200,
Ni1000, PTC and NTC), resistances, potenometers and frequency.
Scalable reading with 4 digits up to 9999 / -1999 with congurable
decimal point. Two independent alarms, congurable as maximum
or minimum, with hysteresis and setpoint.
Oponal 1 or 2 relay outputs, 4/20 mA isolated analog output, and
Modbus RTU isolated serial communicaons.
Front protecon IP50, with oponal IP65. Connecons with plug-in
screw terminals.
Index
1. Panel meter PCE-DPD-U . . . . . . . . . . . . . . . . . . . . 2
1.1 How to order . . . . . . . . . . . . . . . . . . . . . . . . 2
1.2 Front view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.3 Rear view . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.4 Power connecons . . . . . . . . . . . . . . . . . . . . . 3
1.5 Signal connecons . . . . . . . . . . . . . . . . . . . . . 3
1.6 Mechanical dimensions (mm) . . . . . . . . . . . . . . . 3
1.7 Installaon and start-up . . . . . . . . . . . . . . . . . . 3
1.8 Technical specicaons . . . . . . . . . . . . . . . . . . 4
1.9 Internal jumpers . . . . . . . . . . . . . . . . . . . . . . 5
1.10 Measuring AC voltages and AC currents. . . . . . . . . 6
1.11 Measuring DC voltages and DC currents . . . . . . . . 7
1.12 Measuring thermocouples . . . . . . . . . . . . . . . . 8
1.13 Measuring with Pt and Ni probes . . . . . . . . . . . . 9
1.14 Measuring with NTC probes . . . . . . . . . . . . . . .10
1.15 Measuring with PTC probes . . . . . . . . . . . . . . . 10
1.16 Process measures . . . . . . . . . . . . . . . . . . . . .11
1.17 Measuring frequency . . . . . . . . . . . . . . . . . . .11
1.18 Measuring resistances . . . . . . . . . . . . . . . . . . 12
1.19 Measuring potenometers. . . . . . . . . . . . . . . .12
1.20 ‘Fast access’ menu . . . . . . . . . . . . . . . . . . . . 13
1.21 Scaling . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1.22 Oset reading . . . . . . . . . . . . . . . . . . . . . . . 13
1.23 ‘Eco’ mode. . . . . . . . . . . . . . . . . . . . . . . . . 13
1.24 External control . . . . . . . . . . . . . . . . . . . . . . 13
1.25 Second scaling. . . . . . . . . . . . . . . . . . . . . . . 13
1.26 To open the instrument. . . . . . . . . . . . . . . . . . 14
1.27 How to operate the menus. . . . . . . . . . . . . . . .15
1.28 Messages and errors . . . . . . . . . . . . . . . . . . .15
1.29 Conguraon menu. . . . . . . . . . . . . . . . . . . .16
1.29.1 Input signal ranges . . . . . . . . . . . . . . . . . . 16
1.29.2 Scaling . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.29.3 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . 17
1.29.4 Fast access . . . . . . . . . . . . . . . . . . . . . . . 18
1.29.5 Super fast access . . . . . . . . . . . . . . . . . . . 18
1.29.6 External control . . . . . . . . . . . . . . . . . . . .18
1.29.7 Menu ‘Tools’ . . . . . . . . . . . . . . . . . . . . . . 19
1.29.8 Conguring the opons. . . . . . . . . . . . . . . . 21
1.30 Full conguraon menu . . . . . . . . . . . . . . . . . 22
1.31 Precauons on installaon . . . . . . . . . . . . . . . .25
1.32 Factory conguraon . . . . . . . . . . . . . . . . . . .25
1.33 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . 25
1.34 CE declaraon of conformity . . . . . . . . . . . . . . . 25
2. Output and control modules . . . . . . . . . . . . . . . . . 26
2.1 Modules PCE-DPD-U/R1 and PCE-DPD-U/R2 (relay output) . 26
2.2 Module PCE-DPD-U/A1 (analog output) . . . . . . . . . 26
2.3 Module PCE-DPD-U/MB1 (Modbus RTU) . . . . . . . . . 27
Instrument designed for industrial use, highly exible, allows for in-
tegraon in mulple applicaons, reduced cost, excellent quality and
oponal customizaon available.
• ‘Fast access’ menu at front key UP ( ) congurable for fast access 5
to alarm setpoints (see secon 1.20).
• ‘ ’ mode reduces power consumpon Eco
(see secon 1.23).
• Simplied scaling conguraon .(see secon 1.21)
• Funcon ‘ ’ to acvate with a contact a predened external control
funcon (second scaling, decimal point, reading ‘hold’, ‘tare’, memo-
ry of maximum or minimum) .(see secon 1.24)
• 5 congurable brightness levels .(see secon 1.29.7)
1.1 How to order
PCE-DPD
Model Opon 1
U - -
-R1 (1 relay)
-A1 (analog output)
-MB1 (Modbus RTU)
-(empty)
-U
(Power supply
18...265 Vac/dc)
-
Opon 2
-R2 (1 relay)
-(empty)
3
PCE Instruments | www.pce-instruments.com
1.2 Front view
1.4 Power connecons
1.5 Signal connecons
Key ‘UP
Logo Units
Key ‘SQ
Key ‘LE
‘Conguraon menu’
(see secon 1.29)
‘Fast access‘
(see secon 1.29.4)
1.3 Rear view
Signal
(see secon 1.5)
Opon 2 Opon 1
Power
(see secon 1.4)
1 2 3 4 5 8 9 0
Detail of the plug-in screw terminals provided with
the instrument. The instrument is provided with all
terminals needed, both male and female.
Alarm 1Alarm 2
Earth connecon - The instru-
ment does not need earth con-
necon for correct operaon nor
for compliance with security reg-
ulaons. Terminal 9 is is not con-
nected to any internal circuit and
is provided only as a safe place
for earth wire.
Fuse - This instrument has not internal fuse. Conforming to security
regulaon 61010-1, add a protecon fuse to the power line to act as
disconnecon element, easily accessible to the operator and iden-
ed as a protecon device.
250 mA me-lag for power voltage > 50 Vac/dc
400 mA me-lag for power voltage < 50 Vac/dc
~
8 9 0
-
+
~
Power 18 to 265 Vac/dc
Signals up to 600 V and 200 V (AC and DC) must be connected at
terminals 1 and 4. Signals for 5 A current (AC and DC) must be con-
nected at terminals 3 and 4. All other signals must be connected
between terminals 2 and 4. Terminal 5 is a ‘mulfuncon’ terminal,
congurable with one of the following funcons :
• +15 Vdc excitaon voltage (Vexc) for process signals
• +5 Vdc excitaon for potenometer signals
• connecon for the Pt100 third wire compensaon
• external contact ‘EK’ funcon
To select the terminal 5 funcon, select the posion of internal jump-
er ‘T
(see secon 1.9)
.
44
92
Panel
cut-out
16 8
75
96
48
1.6 Mechanical dimensions (mm)
HV signal
5 A {
{~Vac, ±Vdc, resistance, mA, pot,
thermocouple+, Pt+, Ni+, PTC+, NTC+
{
Signal
~600 Vac, 200 Vac ~
±600 Vdc, ±200 Vdc
~5 Aac, ±5 Adc
Common {neutral, 0 V, common
12345
mulfunc.
{Vexc, Pt100 3 wire, Pot+,
‘EK’ external control
1. Open the instrument as indicated at secon and access 1.26
the internal board.
2. Select jumpers ‘S’ for the signal range required (see secon
1.9).
3. Select jumper T’ to assign to mulfuncon terminal 5 the re-
quired funconality .(see secon 1.9)
4. Close the instrument ad indicated at secon 1.26.
5. Connect the input signal and the power supply as indicated at
secons and .1.4 1.5
6. Enter the to congure the instrument conguraon menu
(scaling, alarms, ...) ( ).see secon 1.29
1.7 Installaon and start-up
Units
Units


Product specificaties

Merk: PCE Instruments
Categorie: Meetapparatuur
Model: PCE-DPD-U

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-DPD-U stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur PCE Instruments

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur