PCE Instruments PCE-CL 20 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor PCE Instruments PCE-CL 20 (26 pagina's) in de categorie Meetapparatuur. Deze handleiding was nuttig voor 10 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/26
Manual
Pipe Locator PCE-CL 20
Version 1.0
Date of creation: 21.06.2016
Date of last change: 21.06.2016
PCE Americas Inc.
711 Commerce Way
Suite 8
Jupiter
FL-33458
USA
From outside US: +1
Tel: (561) 320-9162
Fax: (561) 320-9176
info@pce-americas.com
www.pce-instruments.com/english
www.pce-instruments.com
PCE Instruments UK Ltd.
Units 12/13
Southpoint Business Park
Ensign way
Hampshire / Southampton
United Kingdom, SO31 4RF
From outside UK: +44
Tel: (0) 2380 98703 0
Fax: (0) 2380 98703 9
info@industrial-needs.com
Manual
2
Contents
1 Safety notes ............................................................................................................. 3
2 Specification ............................................................................................................ 4
2.1 Technical specications .............................................................................................................. 4
2.2 Delivery contents ........................................................................................................................ 4
3 System description ................................................................................................. 5
3.1 Receiver unit ............................................................................................................................... 5
3.2 Transmitter unit ........................................................................................................................... 7
4 Getting started ......................................................................................................... 8
4.1 Batteries / Power supply ............................................................................................................. 8
4.2 Measurement method ................................................................................................................. 8
4.3 Optional connections to the cable locator .................................................................................. 9
4.3.1 Single-pole use .............................................................................................................................. 9
4.3.2 Two-pole use .................................................................................................................................. 9
5 Operation ................................................................................................................. 9
5.1 Single-pole use ........................................................................................................................... 9
5.1.1 In open current circuits ................................................................................................................... 9
5.1.2 Locating and tracing of lines and sockets .................................................................................... 10
5.1.3 Locating the cable breaks ............................................................................................................ 11
5.1.4 Detection of cable breaks with the help of two transmitters. ....................................................... 12
5.1.5 Troubleshooting of the underoor heating ................................................................................... 13
5.1.6 Detection of a blocked part in an installed non-metallic piping .................................................... 14
5.1.7 Finding metallic tap water- and heating pipe ............................................................................... 15
5.1.8 Finding power supply circuits on the same oor .......................................................................... 16
5.1.9 Tracking an underground current circuit ...................................................................................... 17
5.2 Bipolar use ................................................................................................................................ 18
5.2.1 Use in closed current circuits ....................................................................................................... 18
5.2.2 Detection of fuses ........................................................................................................................ 19
5.2.3 Increase of the eective radius when tracking the loaded current circuits .................................. 23
5.3 24 Additional measuring functions ................................................................................................
5.3.1 Voltage measurement with the transmitter .................................................................................. 24
5.3.2 Lamp function ............................................................................................................................... 24
5.3.3 Backlight ....................................................................................................................................... 24
5.3.4 Mute ............................................................................................................................................. 24
5.3.5 Automatic shutdown ..................................................................................................................... 24
6 Maintenance .......................................................................................................... 24
6.1 Finding errors / Troubleshooting .............................................................................................. 24
6.2 Fuse .......................................................................................................................................... 25
7 Warranty ................................................................................................................. 26
8 Disposal ................................................................................................................. 26
9 Contact ................................................................................................................... 26
9.1 PCE Instruments UK ................................................................................................................ 26
9.2 PCE Americas .......................................................................................................................... 26
Manual
3
Thank you for purchasing a cable locator from PCE Instruments.
1 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
This device may only be used in the way specied in this manual. If used otherwise, this may
cause dangerous situations.
Use the device only when the environmental conditions (temperature, air humidity, ...) are within
the limit values range stated in the specications. Do not expose the device to extreme
temperatures, direct sunlight, extreme air humidity or moisture.
The case should only be opened by qualied personnel of PCE Instruments.
Do not touch the instrument with wet hands.
u should not make any technical changes to the device. Yo
The appliance should only be cleaned with a damp cloth. Do not use any solvent-based cleaners
or abrasives.
The device must only be used with original PCE accessories or equivalent.
Before each use, please inspect the case for damage. In case of any visible damage, please do
not use the device.
Do not expose the instrument to explosive atmospheres.
The limits for the measured parameters given in the specications may not be exceeded under
any circumstances.
Do not expose the device to the extreme temperatures or direct sunlight, dust, strong
electromagnetic radiation, splash water, high humidity or condensation, corrosive or explosive
gases or mechanical vibration.
Before the device is used on the current-carrying components, the corresponding isolation
preparations must be met.
Never attempt to make contact between the two poles of the battery elements, for example, via a
cable connection.
Should the instructions be ignored and not followed, it may lead to the damage of the device and
injury of the operator.
This manual is published by PCE Instruments without any guarantee.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions, please contact PCE Instruments.
Safety symbols
Symbol
Description
Warning: electrical voltage
Non-observance can cause electric shock.


Product specificaties

Merk: PCE Instruments
Categorie: Meetapparatuur
Model: PCE-CL 20

Heb je hulp nodig?

Als je hulp nodig hebt met PCE Instruments PCE-CL 20 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Meetapparatuur PCE Instruments

Handleiding Meetapparatuur

Nieuwste handleidingen voor Meetapparatuur