Manual
Ultrasonic Hardness Tester PCE-5000
Version 1.3
Date of creation: 16.02.2015
Date of last change: 06.01.2021
Manual
2
Contents
1 Introduction ............................................................................................................. 3
2 Safety notes ............................................................................................................. 3
3 Specications .......................................................................................................... 5
3.1 Technical Specications ............................................................................................................. 5
4 Delivery content ...................................................................................................... 6
4.1 Optional accessories .................................................................................................................. 6
5 System description ................................................................................................. 7
5.1 Main structure and basic principle .............................................................................................. 7
5.2 Control elements 8........................................................................................................................
5.3 Display ........................................................................................................................................ 9
5.4 Measurement probe ................................................................................................................. 10
6 Battery .................................................................................................................... 13
7 Operation ............................................................................................................... 14
7.1 Initial operation ......................................................................................................................... 14
7.2 Measurement ............................................................................................................................ 14
8 Settings .................................................................................................................. 16
8.1 Test setup ................................................................................................................................. 16
8.2 System setup ............................................................................................................................ 17
8.2.1 Language option .................................................................................................................. 17
8.2.2 Sound .................................................................................................................................. 17
8.2.3 Battery manager .................................................................................................................. 17
8.2.4 Display ................................................................................................................................. 17
8.2.5 Date ..................................................................................................................................... 17
8.2.6 Restore default .................................................................................................................... 17
8.3 Save setup ................................................................................................................................ 17
8.3.1 Autosave .............................................................................................................................. 17
8.3.2 Result display ...................................................................................................................... 17
8.3.3 On-line operation ................................................................................................................. 17
8.3.4 Part deletion ........................................................................................................................ 17
8.3.5 All deletion ........................................................................................................................... 17
8.4 18 Print setup . ................................................................................................................................
9 Calibration ............................................................................................................. 18
9.1 Reasons to calibrate ................................................................................................................. 18
9.2 Preparations ............................................................................................................................. 18
9.3 Calibration procedure ............................................................................................................... 18
9.3.1 Calibration with two calibration standards ........................................................................... 18
9.3.2 Calibration with one calibration standard ............................................................................ 18
9.3.3 Batch-Mode ......................................................................................................................... 19
10 Disposal ................................................................................................................. 20
11 Contact ................................................................................................................... 20
11.1 PCE Instruments UK ................................................................................................................ 20
11.2 PCE Americas .......................................................................................................................... 20
Manual
3
1 Introduction
Thank you for purchasing an ultrasonic hardness tester from PCE Instruments.
The ultrasonic durometer is a device, based on a patent led in 1961. Therefore the hardness
measurement is performed through a diamond placed on a spring. Due to its design and measurement
method, the ultrasonic durometer allows a simple and non-destructive analysis of metallic objects. The
ultrasonic durometer enables measurements on various construction parts, since it is programmed to
measure with dierent SI-units, the most common of which are the hardness scales according to
Rockwell, Brinell and Vickers. Featuring a RS-232-interface the ultrasonic durometer PCE-5000 can be
connected to a computer in order to read out and print out the measured data. The ultrasonic durometer
allows a detailed overview of all the data, since it can record even the thresholds as well as mean values.
The mean value is automatically generated as soon as more than one measurement is performed with
the ultrasonic durometer PCE-5000. Its design allows reaching even locations that would be otherwise
hard to reach, and it allows reviewing and reading the values comfortably at its graphic display. Due to an
option to calibrate, the ultrasonic durometer can be always calibrated by the user at any time. A
calibration might be necessary, if for example the last measurement was more than three months back, or
when the environment is signicantly dierent from before, if the ultrasonic sensor has already performed
a major amount of measurements, or if the measurement of a dened calibration object shows a
divergent.
Range of use
- Hardness measurements of the anged edge and gear root stamping, mold, sheet, surface
hardened tooth and gear groove
- Hardness tests central axes thin-walled pipes and vessels of ,
- Hardness testing of tires and turbine rotor
- Hardness tests cutting blades of
- Hardness testing of welded parts
- Hardness tests of certain opening depths convex depressions, irregular levels ,
- Hardness tests of most ferrous and non-ferrous metals and other alloys in industrial production.
2 Safety notes
Please read this manual carefully and completely before you use the device for the rst time. The device
may only be used by qualied personnel and repaired by PCE Instruments personnel. There is no
warranty damages or injuries caused by non-observance of the manual. on
- The device may only be used approved temperature range in
- The opening of the case should only be done by qualied personnel of the PCE Instruments.
- The instrument should never be placed with the user interface (e.g. keyboard side on a table )
- You should not make technical changes the device on
- The appliance ould only be cleaned with a damp cloth / use only -neutral cleaner sh pH
- Do not shake the device since internal components may get damaged.
- Do not scratch objects with the diamond.
- Do not disassemble the unit. Otherwise the warranty will expire.
- Do not use the instrument under inammable air environment, otherwise it may take re or
explode.
The ultrasonic hardness tester a precision instrument that must be used with extreme care to avoid is
damage and associated measurement error.
Remove the diamond indenter mentioned above for about half a second after each measurement and
then make a new measurement. Otherwise, the device cann resonance between the indenter ot and a
single sample in a short time.
Please ensure that after each use, the device is always kept in the respective carrying case Avoid .
accidents collisions. and
Do not disconnect the probe from the main unit, since otherwise the device loses its functionality.
Do not use the product near ammable gas, as this could result in re or explosion.