Panasonic LIAC7IM3 Handleiding

Panasonic Airco LIAC7IM3

Lees hieronder de 📖 handleiding in het Nederlandse voor Panasonic LIAC7IM3 (36 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/36
F567343
Operating Instructions
Air-to-Water Heatpump
Model No.
Indoor Unit Outdoor Unit
LIAC7IM3 LIAV7IM
LIAC9IM3 LIAV9IM
ENGLISH
ENGLISH
ENGLISH
ENGLISH
ENGLISH
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Before operating the unit, make sure the installation has been carried out correctly by authorized dealer correctly and
precisely following the installation instructions given.
2 ~ 9
2 ~ 9
2 ~ 9
2 ~ 9
2 ~ 9
FRANÇAIS
FRANÇAIS
FRANÇAIS
FRANÇAIS
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
Avant de faire fonctionner l’unité, assurez-vous que l’installation a été correctement réalisée par un revendeur agréé
et dans le strict respect des consignes d’installation fournies.
10 ~ 17
10 ~ 17
10 ~ 17
10 ~ 17
10 ~ 17
ESPAÑOL
Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como
futuro elemento de consulta.
Antes de operar la unidad asegúrese de que la instalación haya sido realizada correctamente por un distribuidor
autorizado, siguiendo de forma correcta y precisa las instrucciones de instalación dadas.
18 ~ 25
18 ~ 25
18 ~ 25
18 ~ 25
18 ~ 25
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie
sie für die künftige Verwendung auf.
Vor der Inbetriebnahme dieses Geräts ist sicherzustellen, dass die Montage durch einen autorisierten Händler
fachgerecht entsprechend der Installationsanleitung durchgeführt wurde.
26 ~ 33
26 ~ 33
26 ~ 33
26 ~ 33
26 ~ 33
0.2
0.40
0.30.1
MPa
TIMER OUTDOOR
HEAT
SETTING
STATUS
PUMPDW
BOOSTER
QUIET
TANK
WATER OUTLET
C
C
OFF /ON
HEATER
OPERATION
FORCE
HEATER
ACTUAL
TIMER
1
MONTUEWEDTHU FRI SATSUN
SOLAR REMOTE
NOT AVAILABLE
2 3 4 5 6
ON
OFF
01_F567343_OYTH0912-00_EN.indd 1
01_F567343_OYTH0912-00_EN.indd 1
01_F567343_OYTH0912-00_EN.indd 1
01_F567343_OYTH0912-00_EN.indd 101_F567343_OYTH0912-00_EN.indd 1 1/28/2010 9:50:54 AM
1/28/2010 9:50:54 AM
1/28/2010 9:50:54 AM
1/28/2010 9:50:54 AM1/28/2010 9:50:54 AM
2
This manual describes how to operate the Heatpump system
between indoor and outdoor units only.
Other operation such as water tank, radiator, external thermo controller
and under oor system, please refer to respective manufacturer
operation manuals.
SAFETY PRECAUTIONS
T
T
T
TABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTS
ABLE OF CONTENTS
TABLE OF CONTENTS
SAFETY PRECAUTIONS
2~3
CONTROL PANEL
4~7
INDOOR UNIT
8
TROUBLESHOOTING
9
INFORMATION
34~35
NOTE
NOTE
NOTE
NOTE
NOTE
The illustrations in this manual are for
explanation purposes only and may
differ from the actual unit. It is subjected
to change without notice for future
improvement.
OPERA
OPERA
OPERA
OPERATION CONDITION
TION CONDITION
TION CONDITION
TION CONDITION
OPERATION CONDITION
Water outlet
Temperature (°C) Indoor
HEATING Max. 55
Min. 25
Ambient
Temperature (°C) Outdoor
HEATING Max. 35
Min. -20
NOTICE :
When the outdoor temperature
is out of the above temperature
range, the heating capacity will
drop signi cantly and outdoor
unit might stop for protection
control.
To prevent personal injury, injury to others, or property damage, please
comply with the following.
Incorrect operation due to failure to follow instructions below may cause
harm or damage, the seriousness of which is classi ed as below:
WARNING
WARNING
WARNING
WARNING
WARNING
This sign warns of death or serious injury.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
This sign warns of injury or damage to
property.
The instructions to be followed are classi ed by the following symbols:
This symbol denotes an action that is
PROHIBITED.
These symbols denote an actions that
is COMPULSORY.
WARNING
WARNING
WARNING
WARNING
WARNING
INDOOR UNIT AND OUTDOOR UNIT
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction concerning
use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not
play with the appliance.
Please consult authorized dealer or specialist to repair,
install, remove and reinstall the unit. Improper installation
and handling will cause leakage, electric shock or re.
Do not install the unit in a potentially explosive or ammable
atmosphere. Failure to do so could result in re.
Do not insert your ngers or other objects into the
air conditioner indoor or outdoor unit, rotating parts
may cause injury.
Do not touch the outdoor unit during lightning, it may cause
electric shock.
Do not attempt to repair the unit by yourself. Otherwise,
it may cause injury if it is mishandling.
Do not install the indoor unit at outdoor. This is designed for
indoor installation only.
01_F567343_OYTH0912-00_EN.indd 2
01_F567343_OYTH0912-00_EN.indd 2
01_F567343_OYTH0912-00_EN.indd 2
01_F567343_OYTH0912-00_EN.indd 201_F567343_OYTH0912-00_EN.indd 2 1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM1/28/2010 9:50:56 AM
ENGLISH
3
/
/
Floor Heating
Panel
Control Panel
Power Supply
Water Tank Unit
Indoor Unit
Outdoor Unit
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
INDOOR UNIT AND OUTDOOR UNIT
Do not wash the indoor unit with water,
benzene, thinner or scouring powder.
Do not install the unit close to any combustible
equipment or at bathroom. Otherwise, it may
cause electric shock or re.
Do not touch the water discharge pipe at the
indoor unit during operation.
Do not place anything on top or beneath of the
unit.
Do not sit or step on the unit, you
may fall down accidentally.
Do not touch the sharp aluminium n,
sharp parts may cause injury.
Ensure drainage pipe is connected properly.
Otherwise, leakage may occur.
Check the installation rack periodically to make
sure that it is not damaged. After long periods
of use, the strength of the installation rack may
have deteriorated.
CONTROL PANEL
Do not let the control panel get wet. Otherwise,
it may cause electric shock or re.
Do not press the buttons on the control panel
with hard, pointed objects. Otherwise, it may
damage the unit.
Do not wash the control panel with water,
benzene, thinner or scouring powder.
Do
not inspect or service the control panel by
not inspect or service the control panel by
not inspect or service the control panel by
not inspect or service the control panel by
not inspect or service the control panel by
yourself. Please consult authorized dealer
yourself. Please consult authorized dealer
yourself. Please consult authorized dealer
yourself. Please consult authorized dealer.
.
.
.
yourself. Please consult authorized dealer.
Otherwise, it may cause injury if mishandling.
WARNING
WARNING
WARNING
WARNING
WARNING
POWER SUPPLY
Do not use modi ed cord,
joint cord, extension cord or
unspeci ed cord to prevent
overheating and re.
Do not share the same power outlet with other
equipment to prevent overheating and re.
Do not operate with wet hands to prevent electric
shock.
If the supply cord is damage, it must be replaced
by the manufacturer, its service agent or similarly
quali ed persons in order to avoid a hazard.
This unit is equipped with Residue Current
Circuit Breaker (RCCB). It is strongly
recommended to check the operation of the
RCCB after installation and periodically after
servicing or maintenance by authorized dealer
to ensure it is in good working order. Otherwise,
it may cause electrical shock or re in case of
malfunction.
It is recommended to wear gloves during
servicing or maintenance in order to avoid
hazard.
This equipment must be earthed to prevent
electrical shock or re.
In case of emergency or abnormal conditions
(burnt smell, etc), turn off the power supply, and
please consult authorized dealer.
Prevent electric shock by switching off the power
supply when:
- Before cleaning or servicing.
- Extended non-use.
- Abnormally strong lightning activity.
This appliance is for multiple uses. All power
supply circuits must be turn off before access to
any of the terminals in the indoor unit, to avoid
electrical shock, burn or fatal injury.
01_F567343_OYTH0912-00_EN.indd 3
01_F567343_OYTH0912-00_EN.indd 3
01_F567343_OYTH0912-00_EN.indd 3
01_F567343_OYTH0912-00_EN.indd 301_F567343_OYTH0912-00_EN.indd 3 1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM
1/28/2010 9:50:56 AM1/28/2010 9:50:56 AM


Product specificaties

Merk: Panasonic
Categorie: Airco
Model: LIAC7IM3

Heb je hulp nodig?

Als je hulp nodig hebt met Panasonic LIAC7IM3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Panasonic

Handleiding Airco

Nieuwste handleidingen voor Airco