Panasonic CS-FZ50WKE Handleiding

Panasonic Airco CS-FZ50WKE

Lees hieronder de 📖 handleiding in het Nederlandse voor Panasonic CS-FZ50WKE (92 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 18 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/92
Deutsch Español Français English
ACXF55-27061
Model No.
Indoor Unit Outdoor Unit
CS-FZ25WKE
CS-FZ35WKE
CS-FZ50WKE
CS-FZ60WKE
CS-UZ25WKE
CS-UZ35WKE
CS-UZ50WKE
CS-PZ25WKE
CS-PZ35WKE
CS-PZ50WKE
CU-FZ25WKE
CU-FZ35WKE
CU-FZ50WKE
CU-FZ60WKE
CU-UZ25WKE
CU-UZ35WKE
CU-UZ50WKE
CU-PZ25WKE
CU-PZ35WKE
CU-PZ50WKE
Operating Instructions
Air Conditioner
Operating Instructions
Air Conditioner
2-23
Before operating the unit, please read these operating
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read
by the installer before installation.
Remote control is packaged in the indoor unit and removed
by the installer before installation.
Comment utiliser l’appareil
Climatiseur
24-45
Avant d’utiliser l’appareil, veuillez lire ce mode d’emploi dans
son intégralité et conservez-le pour toute référence ultérieure.
Le manuel d’installation inclus doit être conservé et lu par
l’installateur avant l’installation.
La télécommande est emballée dans l’unité intérieure et
retirée par l’installateur avant l’installation.
Instrucciones de funcionamiento
Climatizador de aire
46-67
Antes de utilizar la unidad, sírvase leer atentamente estas
instrucciones de funcionamiento y conservarlas para futuras
consultas.
El instalador debe guardar y leer las Instrucciones de
instalación incluidas antes de la instalación.
El mando a distancia viene embalado en la unidad interior y
debe ser retirado por el instalador antes de la instalación.
Bedienungsanleitung
Klimagerät
68-89
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese
Bedienungsanleitung aufmerksam durch und bewahren Sie
sie als künftige Referenz auf.
Das mitgelieferte Installationshandbuch sollte aufbewahrt und
vor der Installation vom Installateur gelesen werden.
Die Fernbedienung ist im Innengerät verpackt und wird vor
der Installation durch den Installateur entfernt.
ACXF55-27061.indb 1
ACXF55-27061.indb 1
ACXF55-27061.indb 1
ACXF55-27061.indb 1ACXF55-27061.indb 1 12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM12/3/2019 9:45:05 AM
2
Provides maximum comfort with optimal
energy saving methods.
Use remote
control within 8 m
from the remote
control receiver of
the indoor unit.
Quick Guide
Inserting the batteries
OPEN
12
3
1 Pull out the back cover
of remote control.
2
Insert AAA or R03
batteries.
3 Close the cover.
A Clock setting
1 Press and
set the
time .
Press and hold
for approximately
5 seconds to show
time in 12-hour
(am/pm) or 24 hour
indication.
2 Con rm .
e
in
doo
r u
nit
.
i
o
the
A
B
ACXF55-27061.indb 2
ACXF55-27061.indb 2
ACXF55-27061.indb 2
ACXF55-27061.indb 2ACXF55-27061.indb 2 12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM
12/3/2019 9:45:05 AM12/3/2019 9:45:05 AM
3
English
Table of contents
Safety precautions
..........
4-15
How to use
.....................
16-17
To learn more
......................
18
Cleaning instructions
..........
19
Troubleshooting
.............
20-22
Information
...........................
23
Accessories
Remote control
AAA or R03 batteries × 2
Remote control holder
Screws for remote control
holder × 2
The illustrations in this manual are for
explanation purposes only and may differ
from the actual unit. They are subject
to change without notice for future
improvement.
B Basic operation
3 Select the desired
temperature.
Up
Down
Selection range:
16.0 °C ~ 30.0 °C /
60 °F ~ 86 °F.
Press and hold for
approximately 10 seconds
to switch the temperature
indication in °C or °F.
Thank you for purchasing
Panasonic Air Conditioner.
1 Press to start/
stop the operation.
POWER
Please note that
the indication
is on display to
start the unit.
2 Press to select
the desired mode.
DRY
AUTO HEAT
COOL
ACXF55-27061.indb 3
ACXF55-27061.indb 3
ACXF55-27061.indb 3
ACXF55-27061.indb 3ACXF55-27061.indb 3 12/3/2019 9:45:06 AM
12/3/2019 9:45:06 AM
12/3/2019 9:45:06 AM
12/3/2019 9:45:06 AM12/3/2019 9:45:06 AM
4
Safety precautions
To prevent personal injury, injury to others
or property damage, please comply with the
following:
Incorrect operation due to failure to follow
instructions below may cause harm or
damage, the seriousness of which is
classi ed as below:
This appliances is not intended for
accessibility by the general public.
WARNING
This sign
warns of
death or
serious injury.
CAUTION
This sign
warns of
injury or
damage to
property.
The instructions to be followed are classi ed
by the following symbols:
This symbol denotes an
action that is PROHIBITED.
These symbols denote
actions COMPULSORY.
WARNING
Indoor unit and outdoor unit
This appliance can be used by
children aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and
understand the hazards involved.
Children shall not play with the
appliance. Cleaning and user
maintenance shall not be made by
children without supervision.
Please consult authorised dealer or
specialist to clean the internal parts,
repair, install, remove, disassemble
and reinstall the unit. Improper
installation and handling will cause
leakage, electric shock or re.
Con rm with authorised dealer or
specialist on usage of any speci ed
refrigerant type. Using refrigerant
type other than the speci ed may
cause product damage, burst and
injury etc.
Do not use means to accelerate
the defrosting process or to clean,
other than those recommended by
manufacturer.
Any un t method or using
incompatible material may cause
product damage, burst and serious
injury.
Do not install the unit in a potentially
explosive or ammable atmosphere.
Failure to do so could result in re.
Indoor unit
Outdoor unit
Power supply
Remote control
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
Air outlet
ACXF55-27061.indb 4
ACXF55-27061.indb 4
ACXF55-27061.indb 4
ACXF55-27061.indb 4ACXF55-27061.indb 4 12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM12/3/2019 9:45:07 AM
5
English
Do not insert your ngers
or other objects into the air
conditioner indoor or outdoor
unit, rotating parts may cause
injury.
Do not touch the outdoor unit during
lightning, it may cause electric shock.
Do not expose yourself directly to
cold air for a long period to avoid
excess cooling.
Do not sit or step on the unit,
you may fall down accidentally.
Remote control
Do not allow infants and small
children to play with the remote
control to prevent them from
accidentally swallowing the batteries.
Power supply
Do not use a modi ed
cord, joint cord,
extension cord or
unspeci ed cord to
prevent overheating and
re.
To prevent overheating, re or electric
shock:
Do not share the same power outlet
with other equipment.
Do not operate with wet hands.
Do not over bend the power supply
cord.
Do not operate or stop the unit by
inserting or pulling out the power
plug.
If the supply cord is damaged, it must
be replaced by the manufacturer,
service agent or similarly quali ed
persons in order to avoid a hazard.
It is strongly recommended to be
installed with Earth Leakage Circuit
Breaker (ELCB) or Residual Current
Device (RCD) to prevent electric
shock or re.
To prevent overheating, re or electric
shock:
Insert the power plug properly.
Dust on the power plug should be
periodically wiped with a dry cloth.
Stop using the product if any
abnormality/failure occurs and
disconnect the power plug or turn off
the power switch and breaker.
(Risk of smoke/ re/electric shock)
Examples of abnormality/failure
The ELCB trips frequently.
Burning smell is observed.
Abnormal noise or vibration of the
unit is observed.
Water leaks from the indoor unit.
Power cord or plug becomes
abnormally hot.
Fan speed cannot be controlled.
The unit stops running immediately
even if it is switched on for
operation.
The fan does not stop even if the
operation is stopped.
Contact your local dealer immediately
for maintenance/repair.
This equipment must be earthed to
prevent electrical shock or re.
Prevent electric shock by switching
off the power supply and unplug:
- Before cleaning or servicing,
- When extended non-use, or
- During abnormally strong lightning
activity.
Safety precautions
ACXF55-27061.indb 5
ACXF55-27061.indb 5
ACXF55-27061.indb 5
ACXF55-27061.indb 5ACXF55-27061.indb 5 12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM12/3/2019 9:45:07 AM
6
Safety precautions
CAUTION
Indoor unit and outdoor unit
Do not wash the indoor unit with
water, benzine, thinner or scouring
powder to avoid damage or corrosion
at the unit.
Do not use for preservation of precise
equipment, food, animals, plants,
artwork or other objects. This may
cause quality deterioration, etc.
Do not use any combustible
equipment in front of the air ow outlet
to avoid re propagation.
Do not expose plants or pet directly
to air ow to avoid injury, etc.
Do not touch the sharp
aluminium n, sharp parts may
cause injury.
Do not switch ON the indoor unit
when waxing the oor. After waxing,
aerate the room properly before
operating the unit.
Do not install the unit in oily and
smoky areas to prevent damage to
the unit.
Do not dismantle the unit for cleaning
purpose to avoid injury.
Do not step onto an unstable bench
when cleaning the unit to avoid injury.
Do not place a vase or water
container on the unit. Water may
enter the unit and degrade the
insulation. This may cause an electric
shock.
Do not open window or door for
long time during operation, it may
lead to inef cient power usage and
uncomfortable temperature changes.
Prevent water leakage by ensuring
drainage pipe is:
- Connected properly,
- Kept clear of gutters and containers,
or
- Not immersed in water
After a long period of use or use with
any combustible equipment, aerate
the room regularly.
After a long period of use, make
sure the installation rack does not
deteriorate to prevent the unit from
falling down.
Remote control
Do not use rechargeable (Ni-Cd)
batteries. It may damage the remote
control.
To prevent malfunction or damage of
the remote control:
Remove the batteries if the unit
is not going to be used for a long
period of time.
New batteries of the same type must
be inserted following the polarity
stated.
Power supply
Do not disconnect the plug by pulling
the cord to prevent electric shock.
ACXF55-27061.indb 6
ACXF55-27061.indb 6
ACXF55-27061.indb 6
ACXF55-27061.indb 6ACXF55-27061.indb 6 12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM12/3/2019 9:45:07 AM
7
English
WARNING
This appliance is lled with
R32
(mild ammable refrigerant).
If the refrigerant is leaked and
exposed to an external ignition
source, there is a risk of re.
Indoor unit and outdoor unit
The appliance shall be installed, and/
or operated in a room with oor area
larger than Amin (m²) and keep away
from ignition sources, such as heat/
sparks/open ame or hazardous
areas such as gas appliances,
gas cooking, reticulated gas
supply systems or electric cooking
appliances, etc.(Refer to Table A of
Installation instructions table for Amin
(m²))
Be aware that refrigerant may
not contain an odour, highly
recommended to ensure suitable
ammable refrigerant gas detectors
are present, operating and able to
warn of a leak.
Keep any required ventilation
openings clear of obstruction.
Do not pierce or burn as the
appliance is pressurized. Do not
expose the appliance to heat, ame,
sparks, or other sources of ignition.
Else it may explode and cause injury
or death.
Precaution for using R32
refrigerant
The basic installation work procedures are
the same as conventional refrigerant (R410A,
R22) models.
Since the working pressure is
higher than that of refrigerant R22
models, some of the piping and
installation and service tools are
special. Especially, when replacing
a refrigerant R22 model with a
new refrigerant R32 model, always
replace the conventional piping and
are nuts with the R32 and R410A
piping and are nuts on the outdoor
unit side.
For R32 and R410A, the same are
nut on the outdoor unit side and pipe
can be used.
The mixing of different refrigerants
within a system is prohibited. Models
that use refrigerant R32 and R410A
have a different charging port thread
diameter to prevent erroneous
charging with refrigerant R22 and for
safety.
Therefore, check beforehand. [The
charging port thread diameter for R32
and R410A is 1/2 inch.]
Must always ensure that foreign
matter (oil, water, etc.) does not enter
the piping. Also, when storing the
piping, securely seal the opening by
pinching, taping, etc. (Handling of
R32 is similar to R410A.)
Operation, maintenance, repairing
and refrigerant recovery should be
carried out by trained and certi ed
personnel in the use of ammable
refrigerants and as recommended
by the manufacturer. Any personnel
conducting an operation, servicing
or maintenance on a system or
associated parts of the equipment
should be trained and certi ed.
Safety precautions
ACXF55-27061.indb 7
ACXF55-27061.indb 7
ACXF55-27061.indb 7
ACXF55-27061.indb 7ACXF55-27061.indb 7 12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM12/3/2019 9:45:07 AM
8
Any part of refrigerating circuit
(evaporators, air coolers, AHU,
condensers or liquid receivers) or
piping should not be located in the
proximity of heat sources, open
ames, operating gas appliance or
an operating electric heater.
The user/owner or their authorised
representative shall regularly check
the alarms, mechanical ventilation
and detectors, at least once a
year, where as required by national
regulations, to ensure their correct
functioning.
A logbook shall be maintained. The
results of these checks shall be
recorded in the logbook.
In case of ventilations in occupied
spaces shall be checked to con rm
no obstruction.
Before a new refrigerating system
is put into service, the person
responsible for placing the system
in operation should ensure that
trained and certi ed operating
personnel are instructed on the
basis of the instruction manual
about the construction, supervision,
operation and maintenance of the
refrigerating system, as well as the
safety measures to be observed,
and the properties and handling of
the refrigerant used.
The general requirement of trained
and certi ed personnel are indicated
as below:
a) Knowledge of legislation,
regulations and standards
relating to ammable
refrigerants; and,
b) Detailed knowledge of and
skills in handling ammable
refrigerants, personal protective
equipment, refrigerant leakage
prevention, handling of cylinders,
charging, leak detection,
recovery and disposal; and,
c) Able to understand and to apply
in practice the requirements
in the national legislation,
regulations and Standards; and,
d) Continuously undergo regular
and further training to maintain
this expertise.
e) Air-conditioner piping in the
occupied space shall be installed
in such a way to protect against
accidental damage in operation
and service.
f) Precautions shall be taken to
avoid excessive vibration or
pulsation to refrigerating piping.
g) Ensure protection devices,
refrigerating piping and ttings
are well protected against
adverse environmental effects
(such as the danger of water
collecting and freezing in relief
pipes or the accumulation of dirt
and debris).
h) Expansion and contraction of
long runs piping in refrigerating
systems shall be designed and
installed securely (mounted
and guarded) to minimize the
likelihood hydraulic shock
damaging the system.
i) Protect the refrigerating
system from accidental rupture
due to moving furniture or
reconstruction activities.
j) To ensure no leaking, eld-made
refrigerant joints indoors shall
be tightness tested. The test
method shall have a sensitivity
of 5 grams per year of refrigerant
or better under a pressure of at
least 0.25 times the maximum
allowable pressure (>1.04 MPa,
max 4.15 MPa). No leak shall be
detected.
Safety precautions
ACXF55-27061.indb 8
ACXF55-27061.indb 8
ACXF55-27061.indb 8
ACXF55-27061.indb 8ACXF55-27061.indb 8 12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM
12/3/2019 9:45:07 AM12/3/2019 9:45:07 AM
10
Safety precautions
2-2. Work
Prior to beginning work on systems
containing ammable refrigerants,
safety checks are necessary to
ensure that the risk of ignition
is minimised.
For repair to the
refrigerating system, the precautions in
#2-2 to #2-8 must be followed before
conducting work on the system.
Work shall be undertaken under
a controlled procedure so as to
minimize the risk of a ammable gas
or vapour being present while the
work is being performed.
All maintenance staff and others
working in the local area shall be
instructed and supervised on the
nature of work being carried out.
Avoid working in con ned spaces.
Always ensure away from source, at
least 2 meter of safety distance, or
zoning of free space area of at least
2 meter in radius.
Wear appropriate protective
equipment, including respiratory
protection, as conditions warrant.
Keep all sources of ignition and hot
metal surfaces away.
2-3. Checking for presence of
refrigerant
The area shall be checked with an
appropriate refrigerant detector prior
to and during work, to ensure the
technician is aware of potentially
ammable atmospheres.
Ensure that the leak detection
equipment being used is suitable for
use with ammable refrigerants, i.e.
non sparking, adequately sealed or
intrinsically safe.
In case of leakage/spillage
happened, immediately ventilate
area and stay upwind and away
from spill/release.
In case of leakage/spillage
happened, do notify persons down
wind of the leaking/spill, isolate
immediate hazard area and keep
unauthorized personnel out.
2-4. Presence of re extinguisher
If any hot work is to be conducted
on the refrigerating equipment or
any associated parts, appropriate
re extinguishing equipment shall be
available at hand.
Have a dry powder or CO2 re
extinguisher adjacent to the
charging area.
2-5. No ignition sources
No person carrying out work in
relation to a refrigerating system
which involves exposing any pipe
work that contains or has contained
ammable refrigerant shall use any
sources of ignition in such a manner
that it may lead to the risk of re
or explosion. He/She must not be
smoking when carrying out such
work.
All possible ignition sources,
including cigarette smoking, should
be kept suf ciently far away from
the site of installation, repairing,
removing and disposal, during which
ammable refrigerant can possibly
be released to the surrounding
space.
Prior to work taking place, the area
around the equipment is to be
surveyed to make sure that there
are no ammable hazards or ignition
risks.
“No Smoking” signs shall be
displayed.
2-6. Ventilated area
Ensure that the area is in the open
or that it is adequately ventilated
before breaking into the system or
conducting any hot work.
A degree of ventilation shall continue
during the period that the work is
carried out.
The ventilation should safely
disperse any released refrigerant
and preferably expel it externally
into the atmosphere.
ACXF55-27061.indb 10
ACXF55-27061.indb 10
ACXF55-27061.indb 10
ACXF55-27061.indb 10ACXF55-27061.indb 10 12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM12/3/2019 9:45:08 AM
12
Safety precautions
3. Repairs to sealed components
During repairs to sealed
components, all electrical supplies
shall be disconnected from the
equipment being worked upon prior
to any removal of sealed covers, etc.
If it is absolutely necessary to have
an electrical supply to equipment
during servicing, then a permanently
operating form of leak detection
shall be located at the most critical
point to warn of a potentially
hazardous situation.
Particular attention shall be paid
to the following to ensure that by
working on electrical components,
the casing is not altered in such a
way that the level of protection is
affected.This shall include damage
to cables, excessive number of
connections, terminals not made
to original speci cation, damage to
seals, incorrect tting of glands, etc.
Ensure that apparatus is mounted
securely.
Ensure that seals or sealing
materials have not degraded
such that they no longer serve the
purpose of preventing the ingress of
ammable atmospheres.
Replacement parts shall be in
accordance with the manufacturer’s
speci cations.
NOTE: The use of silicon sealant
may inhibit the effectiveness of some
types of leak detection equipment.
Intrinsically safe components do not
have to be isolated prior to working
on them.
4. Repair to intrinsically safe
components
Do not apply any permanent
inductive or capacitance loads to
the circuit without ensuring that
this will not exceed the permissible
voltage and current permitted for the
equipment in use.
Intrinsically safe components are
the only types that can be worked
on while live in the presence of a
ammable atmosphere.
The test apparatus shall be at the
correct rating.
Replace components only with
parts speci ed by the manufacturer.
Unspeci ed parts by manufacturer
may result ignition of refrigerant in
the atmosphere from a leak.
5. Cabling
Check that cabling will not be
subject to wear, corrosion, excessive
pressure, vibration, sharp edges or
any other adverse environmental
effects.
The check shall also take into
account the effects of aging or
continual vibration from sources
such as compressors or fans.
6. Detection of ammable
refrigerants
Under no circumstances shall
potential sources of ignition be used
in the searching or detection of
refrigerant leaks.
A halide torch (or any other detector
using a naked ame) shall not be
used.
ACXF55-27061.indb 12
ACXF55-27061.indb 12
ACXF55-27061.indb 12
ACXF55-27061.indb 12ACXF55-27061.indb 12 12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM12/3/2019 9:45:08 AM
13
English
7. The following leak detection
methods are deemed
acceptable for all refrigerant
systems
No leaks shall be detected when
using detection equipment with
a sensitivity of 5 grams per year
of refrigerant or better under a
pressure of at least 0.25 times the
maximum allowable pressure
(>1.04 MPa, max 4.15 MPa), for
example, a universal sniffer.
Electronic leak detectors may
be used to detect ammable
refrigerants, but the sensitivity may
not be adequate, or may need re-
calibration.
(Detection equipment shall be
calibrated in a refrigerant-free area.)
Ensure that the detector is not a
potential source of ignition and is
suitable for the refrigerant used.
Leak detection equipment shall be
set at a percentage of the LFL of the
refrigerant and shall be calibrated
to the refrigerant employed and the
appropriate percentage of gas (25 %
maximum) is con rmed.
Leak detection uids are also
suitable for use with most
refrigerants, for example, bubble
method and uorescent method
agents. The use of detergents
containing chlorine shall be avoided
as the chlorine may react with the
refrigerant and corrode the copper
pipe-work.
If a leak is suspected, all naked
ames shall be removed/
extinguished.
If a leakage of refrigerant is found
which requires brazing, all of the
refrigerant shall be recovered from
the system, or isolated (by means
of shut off valves) in a part of the
system remote from the leak. The
precautions in #8 must be followed
to remove the refrigerant.
8. Removal and evacuation
When breaking into the refrigerant
circuit to make repairs – or for
any other purpose – conventional
procedures shall be used. However,
it is important that best practice
is followed since ammability is
a consideration. The following
procedure shall be adhered to:
remove refrigerant -> purge the
circuit with inert gas -> evacuate
-> purge with inert gas -> open the
circuit by cutting or brazing.
The refrigerant charge shall be
recovered into the correct recovery
cylinders.
The system shall be purged with
OFN to render the appliance safe.
This process may need to be
repeated several times.
Compressed air or oxygen shall not
be used for this task.
Purging shall be achieved by
breaking the vacuum in the system
with OFN and continuing to ll until
the working pressure is achieved,
then venting to atmosphere, and
nally pulling down to a vacuum.
This process shall be repeated until
no refrigerant is within the system.
When the nal OFN charge is used,
the system shall be vented down
to atmospheric pressure to enable
work to take place.
This operation is absolutely vital if
brazing operations on the pipe work
are to take place.
Ensure that the outlet for the
vacuum pump is not close to any
potential ignition sources and there
is ventilation available.
OFN = oxygen free nitrogen,
type of inert gas.
Safety precautions
ACXF55-27061.indb 13
ACXF55-27061.indb 13
ACXF55-27061.indb 13
ACXF55-27061.indb 13ACXF55-27061.indb 13 12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM12/3/2019 9:45:08 AM
16
How to use
To reach set temperature quickly
This operation stops automatically after 20 minutes.
POWERFUL
To adjust FAN SPEED and QUIET condition
FAN SPEED/
FAN SPEED:
For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
QUIET:
This operation reduces air ow noise.
AUTO
FAN QUIET
Indicator
POWERFUL
FAN SPEED/
Not used
in normal
operations.
Press to restore
the remote
control to default
setting.
POWER
TIMER
To maximise comfort while sleeping
This operation provides you with a comfortable environment while sleeping. It will
automatically adjust the sleep pattern temperature during the activation period.
The indoor unit indicator will dim when this operation is activated. This is not applicable if
the indicator brightness has been manually dimmed.
This operation is incorporated with the activation timer (0.5, 1, 2, 3, 4, 5, 6, 7, 8 or 9 hours).
This operation can be set together with timer. Sleep operation has the priority over OFF
timer.
This operation can be cancelled by pressing the respective button until the sleep timer
reaches 0.0h.
SLEEP
To adjust air ow direction
AIR SWING
Upper direction
Upper direction:
Do not adjust the ap by hand.
Lateral
direction
Lateral direction:
For lateral direction, it is
manually adjustable as
shown.
ACXF55-27061.indb 16
ACXF55-27061.indb 16
ACXF55-27061.indb 16
ACXF55-27061.indb 16ACXF55-27061.indb 16 12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM
12/3/2019 9:45:08 AM12/3/2019 9:45:08 AM
17
EnglishHow to use
Note
SLEEP
,
POWERFUL POWERFUL
,
FAN SPEED/
Can be selected at the same time.
Can be activated in all modes.
Can be cancelled by pressing the
respective button again.
POWERFUL, QUIET and FAN SPEED
cannot be selected at the same time.
To set the timer
ON
OFF
TIMER
SET
C
AN
C
E
L
21 3
1Select ON or OFF
timer
Example:
OFF at 22:00
Each time pressed:
(exit setting)
2Set the time
3Con rm
To cancel ON or OFF timer, press
or to select respective or then
press .
If timer is cancelled manually or due to
power failure, you can restore the timer
again by pressing or to select
respective or then press .
The nearest timer setting will be displayed
and will activate in sequence.
Timer operation is based on the clock set
in the remote control and repeats daily
once set. For clock setting, please refer to
Quick Guide.
2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset time.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor Outdoor *1Outdoor *2
DBT WBT DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8) 43 (109.4) 26 (78.8)
Min. 16 (60.8) 11 (51.8) 5 (41.0) - -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4) 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2) -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature
*1
CU-PZ25WKE, CU-PZ35WKE, CU-PZ50WKE
*2
CU-FZ25WKE, CU-FZ35WKE, CU-FZ50WKE, CU-FZ60WKE, CU-UZ25WKE, CU-UZ35WKE, CU-UZ50WKE
ACXF55-27061.indb 17
ACXF55-27061.indb 17
ACXF55-27061.indb 17
ACXF55-27061.indb 17ACXF55-27061.indb 17 12/3/2019 9:45:09 AM
12/3/2019 9:45:09 AM
12/3/2019 9:45:09 AM
12/3/2019 9:45:09 AM12/3/2019 9:45:09 AM


Product specificaties

Merk: Panasonic
Categorie: Airco
Model: CS-FZ50WKE
Kleur van het product: Wit
Soort: Splitssysteem
Gebruikershandleiding: Ja
Koelend medium: R32
Inverter technologie: Nee
Multi-split: Ja
Air conditioner functies: Cooling,Dehumidifying,Heating
Seizoensgebonden rendement (koeling) (SEER): 6.5
Seasonal efficiency rating (verwarming) (SCOP): 4.1
Energie-efficiëntieklasse (verwarming) (gemiddelde stookseizoen): A
Jaarlijks energieverbruik (koelen): 269 kWu
Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): - kWu
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): 1436 kWu
Energie-efficiëntieklasse (koeling): A++
Extern geluidsniveau: 49 dB
Intern geluidsniveau (hoge snelheid): 44 dB
Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): 980 W
Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): 5400 W
Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): 7500 W
Energieverbruik per uur (koeling): - kWu
Energieverbruik per uur (verwarming): - kWu
Breedte binnenunit: 779 mm
Diepte binnenunit: 209 mm
Hoogte binnenunit: 290 mm
Bedrijfstemperatuur ( koeling ) ( T - T ): -10 - 43 °C
Koeling energie efficientie: 3.03
Verwarming energie efficientie: 3.42
Indoor unit type: Muur-montage
Indoor eenheid gewicht: 8000 g
Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): - kWu
Outdoor eenheid gewicht: 3600 g
Afstandsbediening inbegrepen: Ja
Breedte buitenunit: 824 mm
Diepte buitenunit: 299 mm
Hoogte buiteneenheid: 619 mm
Indoor units hoeveelheid: 1
Outdoor units hoeveelheid: 1
AC-ingangsspanning: 230 V
AC-ingangsfrequentie: 50 Hz
Slanglengte (max): 15 m
Bedrijfstemperatuur (verwarming) (T-T): -15 - 24 °C
Comfort-slaapstand: Ja
Binnenunit geluidsniveau (lage snelheid): 34 dB
Slanglengte (min): 3 m
Binnenunit geluidsvermogensniveau: 37 dB
Buitenunit geluidsvermogensniveau: 48 dB

Heb je hulp nodig?

Als je hulp nodig hebt met Panasonic CS-FZ50WKE stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Panasonic

Handleiding Airco

Nieuwste handleidingen voor Airco