Panasonic CS-C242KR Handleiding
Lees hieronder de π handleiding in het Nederlandse voor Panasonic CS-C242KR (24 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/24
F563263
Room Air Conditioner
Operating Instructions
ENGLISH ............ P. 1 β P. 22
Before using your air-conditioner, please
read this operating instructions carefully
and keep it for future reference.
Outdoor
Model CU-C182KR
CU-C242KR
Indoor
Model CS-C182KR
CS-C242KR
β²
1
Before use
Contents
Safety Precautions ................................................ 2 β 4
β Installation precautions
β Operation precautions
Name of Each Part ................................................ 5 β 6
β Indoor unit
β Outdoor unit
β Accessories
β Remote control
Preparation Before Operation ............................... 7 β 8
β Before operating the unit
β How to insert batteries
β Operating the remote control
How to Operate ................................................... 9 β 10
Setting the Timer ............................................... 11 β 12
Convenient Operation ....................................... 13 β 14
β Sleep mode
β When remote control cannot be used
β OFF/ON remote control signal receiving
sound
Operation Hints ................................................. 15 β 16
Better Care and Maintenance ........................... 17 β 18
β Cleaning the air conditioner and air ο¬lters
β Cleaning of front panel
β Replacement of air purifying ο¬lters
β When not using the air conditioner for a
long period
β Pre-season inspection
Troubleshooting
........................................
19 β 20
β Normal operation
β Abnormal operation
β Call the dealer immediately
β
β
β
β
β
β
β
β
β
How to use
If necessary
β²
2
ENGLISH
Safety Precautions
β Do not install, remove and reinstall the unit yourself.
Improper installation will cause leakage, electric shock or fire. Please engage an authorized dealer or
specialist for the installation work.
Warning
To prevent personal injury, injury to others and property damage, the following instructions must be followed.
β Incorrect operation due to ignoring of instructions will cause harm or damage, the seriousness of which is
classified as follows :
Caution
Warning : This sign warns of death or serious injury.
This sign warns of injury or damage to property only.
This symbol (with a white background) denotes an action that is
PROHIBITED.
These symbols (with a black background) denote an action that is
COMPULSORY.
β The instructions to be followed are classified by the following symbols :
!
!
!
!
Installation precautions
Before operating, please read the following βSafety Precautionsβ carefully.
β This room air conditioner must be earthed.
Improper grounding could cause
electric shock.
β Do not install the unit in a place where there
may be explosive gas leaks.
Gas leaks near the unit could cause
fires.
β Ensure that drainage piping is connected
properly.
Otherwise, water will leak out.
Caution :
OFF
β²
3
Operation precautions
β Insert the power plug
properly.
Heat generated by a loose power
plug could cause electric shock
or fire. Electrical outlet and power
plug shall be easily accessible.
β Do not modify the length of
the power cord or use an
extension cord.
It could cause electric shock or
fire.
β Do not be directly exposed
to the cold airstream for too
long.
It could lead to health problems.
β Do not operate or stop the
unit by inserting or pulling
out the power plug.
It could cause electric shock or fire.
β Do not operate the unit with
wet hands.
It could cause an electric shock.
β If there is a smell of burning,
stop the air conditioner and
disconnect the power supply.
The heat generated could cause
electric shock or fire. Please con-
sult an authorized dealer or service
centre.
Warning
β Do not damage or use an
unspecified power cord.
It will cause electrical shock or
fire.
β Do not insert finger, sticks
or other objects into the
units.
It could lead to physical injury
and cause damage to the units.
β Do not try to repair the unit
yourself.
It could lead to fire or cause an
electric shock. Please call an au-
thorized dealer or service centre.
!
OFF
Switch off
the breaker.
Disconnect
the power
plug.
β²
4
ENGLISH
β Do not remove the power
plug by pulling the cord.
Hold the plug when disconnect-
ing the plug from the wall outlet.
β Do not use for other pur-
poses.
Do not use for preservation pur-
poses. It will affect food quality,
animals or plants.
β Do not wash the unit with
water.
It could cause an electric shock.
Caution
β When cleaning the unit, re-
move the plug.
This is to prevent injury due to the
rotating fan in the unit.
β
Ventilate the room regularly.
Since windows are kept closed, it
does good to open them periodi-
cally to ventilate the room.
β Do not sit or place anything
on the outdoor unit.
You might fall off or the unit might
collapse.
β Switch off the power supply if
the unit is not going to be
used for a long period of time.
If dust accumulates on the plug, it
will generate heat and this could
cause a fire.
β Do not place combustor in the
path of the airflow from the
unit.
Incomplete combustion could
cause toxic gas (CO) poisoning.
β Inspect the unit for any
damage.
Ensure that the necessary repairs
are carried out.
OFF
Switch off
the breaker.
Disconnect
the power
plug.
!
OFF
β²
5
Name of Each Part
Indoor unit
Front Panel Air Intake Vent
POWER : Red
SLEEP : Orange
TIMER : Orange
Air Outlet Vent
Operation Indication
Lamps (LED)
Test Run Button
Panel Opener
Horizontal
Airο¬ow Direction Louver
(Manually adjusted)
Vertical Airο¬ow
Direction Louver Signal
Receptor Power Switch
Power Supply
Cord
Auto Operation Button
Air Outlet Vents
Drain Hose
Piping
(Rear)
(Side)
Outdoor unit
Ground
Terminal
(Inside cover)
Air Intake Vents
β²
6
ENGLISH
Separate displays and functions are available when the door is opened.
Remote Control Two R03 (AAA) dry-cell
batteries or equivalent
Air Purifying Filters
(Catechin Air Purifying Filters and
Deodorizing Filters)
Remote control
Operation Display
Door
Airο¬ow Volume
Selection Button
OFF/ON Button
Airο¬ow Direction Manual
Control Button
Signal Transmitter
OFF/ON
SLEEP
PM
MODE TEMP. FAN SPEED
MANUAL
SWING
AIR SWING
FAN
DRY
COOL
AUTO
AM
ON-TIMER
OFF-TIMER
Β°C
AUTO FAN
c
h j k
m n o
Airο¬ow Direction Auto
Control Button
OFF-Timer Button ON-Timer Button
Set Button
Cancellation Button
Clock Button
Time
Button
q
OFF-TIMER ON-TIMER
CANCEL SET
TIME
Door
Operation Mode
Selection Button
Room Temperature
Setting Button
Sleep Mode
Operation Button
OFF/ON
SLEEP
PM
MODE TEMP. FAN SPEED
MANUAL
SWING
AIR SWING
FAN
DRY
COOL
AUTO
AM
ON-TIMER
OFF-TIMER
Β°C
AUTO FA N
c
h j k
m n o
Accessories
β²
7
Airο¬ow Direction Adjustment
Preparation Before Operation
Before operating the unit
β Open the front panel. β Switch on the power
switch and close the front
panel.
β Remove air filter.
β Insert air purifying filter.
Insert the air filters.
Hold the tab to raise up
slightly and then pull down.
234
Hold the panel openers at both
sides and pull up the front panel.
Air
filter
Be careful not to
hurt your hands by
metal parts.
2
1
1
Air purifying
filter
β Connect the power
supply cord to an
independent power
supply.
Use the air conditioner under the following conditions.
(Unit in Β°C)
DBT: Dry Bulb Temp
WBT: Wet Bulb Temp
Maximum Temperature
Minimum Temperature
Indoor Outdoor
DBT
32
16
WBT
23
11
DBT
43
16
WBT
26
11
β²
8
ENGLISH
OPEN
er
er
OPEN
How to insert batteries
Operating the remote control
e r Be sure
that the (+) and
(β) directions
are correct.
β Fix the cover to the back of the remote
control (βPM 12:00β will flash in the opera-
tion display.)
If the display does not appear when the batteries
are inserted, remove the batteries and
insert them once more.
β Aim at the signal receptor on the room air condi-
tioner when operating.
β Do not drop or throw the remote control.
β Do not place the remote control in a location that
is exposed to direct sunlight or next to a heating
unit or other heat source.
β Signal received sound :
One short beep or one long beep.
Set the power switch to β β (OFF) when:t
β The air conditioner is not going to be used for
an extended period of time.
If the power switch is left at βIβ (ON), approximately
3.25 watts of electric power are used even if the main
unit is turned off by remote control.
β There is a danger of lightning.
The air conditioner is provided with a built-in protective
device, but the control equipment may be adversely
affected depending on the extent of lightning activity.
Regarding the batteries.
β The batteries can be used for approximately one year.
β Do not use rechargeable (Ni-Cd) batteries,
because such batteries differ from standard
dry-cell batteries in shape, dimensions and
performance.
β Be sure to replace the batteries with two new
batteries of the same type.
β Remove the batteries if the air conditioner is not going
to be used for an extended period of time.
Make sure that the
signal path is
not
obstructed.
The maximum dis-
tance at which signals
can be received is
about 10 m.
12
12
12
12
12
00
00
00
00
00
:
:
:
:
:
PM
Gently press the
place marked
[OPEN] and slide
the cover toward
you.
(Two R03 (AAA) dry-cell
batteries or equivalent)
β²
9
Recommended temperature for health
and comfort.
<Operation Details>
AUTO β Automatic Operation.
β Once the Automatic Operation is selected, the in-
door temperature sensor operates automatically
to select the desired operation mode with Cooling
or Soft Dry.
β After the operation mode has been selected, the
mode does not change.
β Temperature is not displayed on remote control
during Auto mode operation.
β If there is a power failure, operation will be
automatically restarted after 3 minutes when the
power is resumed with previous operation mode
and airflow direction.
(When the operation is not stopped by remote
control.)
β If you do not intend to continue the operation
when the power is resumed, switch off the power
switch at main unit or power supply.
When you switch on the power switch, the
operation will be automatically restarted
with previous operation mode and airflow
direction.
Note: 1. If you do not require Auto Restart
Control, please consult your dealer.
2. Auto Restart Control is not available
when Timer or Sleep Mode is set.
Auto Restart Control.
For Cooling : 26Β°C β 28Β°C
For Soft Dry : 1Β°C β 2Β°C lower than
room temperature.
Cooling operation
until room tem-
perature reaches the
setting temperature
Operation will be switched
on and off for up to
10 min on and 6 min off
during Soft Dry
Super Low air-
flow amount
When room temperature reaches the setting temperature,
operation will switch to Soft Dry.
Setting
Temperature
DRY β Soft Dry Operation.
β Soft Dry is a very gentle Cooling Operation
consisting primarily of dehumidifying. It does not
lower the room temperature very much.
How to Operate
OFF/ON
AUTO FAN
SLEEP
MODE TEMP. FAN SPEED
MANUAL
SWING
AIR SWING
AUTO
h j k
m
COOLING
SOFT DRY
Temperature
23Β°C
Temp. set at
25Β°C
Temp. set at
22Β°C
Automatic Operation Standard temperature
β²
10
ENGLISH
Air
Circulation
Cooling
Soft Dry
FAN β Air Circulation Operation.
β When the room temperature reaches the setting
temperature, operation commences at Low air-
flow volume. It stops when the room temperature
drops to 2Β°C below the setting temperature (It is
useful when using a heater).
Automatic Airο¬ow Volume.
β The speed of the indoor fan is adjusted automati-
cally according to the operation. The indoor fan
stops occasionally during cooling operation.
Range of louver adjustment.
34Β°
57Β°
MODE
OFF/ON I
FAN SPEED
i
TEMP.
MANUAL
SWING
β¨ β¨ β¨
h j k h j k h j k
m n
2Β°C lower than
standard
standard
nn o
2Β°C higher than
standard
βΌ
βΌ
1
2
3
4
5
Press to select operation mode.
β The display changes in the order
AUTO β COOL DRY FANβ β
each time the button is pressed.
Press to start the operation.
β Operation indication lamp (RED) will light up.
β Press once more, to stop the operation.
Press to select airο¬ow volume.
β The display changes in the order.
AUTO FAN
Automatic Low Medium High
Press to select room temperature.
β Cooling, Soft Dry, Air Circulation β Select temperature as desired.
(16Β°C ~ 30Β°C)
β Automatic. (Refer <Operation Details>)
Press
MANUAL
continuously.
β The vertical airflow direction louver will move up and down. Release the
button when the louver is at the desired position.
Press
SWING
.
β The vertical airflow direction louver will swing up and down automatically.
To stop the automatic airflow direction operation, press
MANUAL
button.
l lll lllll
β²
11
<Note>
Regarding remote control. β If the current time is not set correctly, correct
Timer setting will not be possible.
β When the Timer is set, the current time display will
vanish.
β [RESET] points will clear the memory once they
are shorted.
β [B β A] switch is used when two air conditioners
units have been installed in one room. Please
consult your dealer.
OPEN
[RESET] points
Setting the Timer
[B β A] switch
If there is a power failure.
OFF-TIMER SET
β‘
To reset the Timer.
(Example) If the OFF Timer has been set.
β Even if there is a power failure, the setting
time is still stored in the memory because the
remote control is a battery operated type.
q
OFF/ON
SLEEP
PM
OFF-TIMER TIME ON-TIMER
SET
CANCEL
11 30:
β²
12
ENGLISH
β Setting the OFF Timer.
β Setting the ON Timer.
Automatic, Cooling and Soft Dry :
15 minutes before
Timer
β The ON Timer and OFF Timer can only be set
once during a day.
β The operation will start before the actual setting
time with ON Timer setting.
This is to allow time to attain your desired set
temperature.
If the air conditioner is set before you go out,
the room temperature will be close to your
desired temperature when you return.
This is useful for saving electricity costs in-
curred by forgetting to turn oο¬ the air condi-
tioner.
To set the current time.
β Set hours and minutes
To set the Timer.
β OFF Timer Set hours and minutes
The β
OFF-TIMER
β will blink.
β ON Timer Set hours and minutes
The β
ON-TIMER
β will blink.
To cancel the Timer.
β OFF Timer
To change the Timer setting time.
β (Example) To change the ON Timer
setting time. Change hours and minutes setting
TIME
.... to advance the time
.... to reverse the time
.... to increase 10 minutes
each step.
.
... to decrease 10 minutes
each step.
TIME
The Timer indication lamp at main
unit will light up. LED colour: Orange.
βThe Timer indication lamp at
main unit will go oο¬.
βTo cancel the ON Timer, follow
the same procedure.
TIME
.... to increase 10 minutes
each step.
.
... to decrease 10 minutes
each step.
The Timer indication lamp at main
unit will light up. LED colour: Orange.
.
... to increase 10 minutes
each step.
.
... to decrease 10 minutes
each step.
TIME
q
OFF-TIMER
q
SET
0N-TIMER
SET
OFF-TIMER
CANCEL
SET
0N-TIMER
β²
13
Convenient Operation
Sleep Mode
This is to gain a comfortable room temperature while sleeping.
Sleep Mode Operation.
β When the room temperature reaches
the setting temperature or after 1
hour of operation, sleep shift
operation starts and the airflow
volume will automatically change to
low.
β Sleep Mode Operation time is 8
hours.
β When using together with the Timer,
the Timer has priority.
<Information>
β Cooling or Soft Dry Operation for Sleep Mode movement will start to avoid overcooling.
To set Sleep Mode.
β Press
(The sleep indication lamp on the
main unit will light up.)
To cancel Sleep Mode.
β Press once more
(The sleep indication lamp on the
main unit will switch off.)
Approx. 0.5Β°C increase
Approx. 0.5Β°C increase
1 hour
0 β 1 hour
Approx. 8 hours after
sleep shift operation
starts, stops automati-
cally.
TEMP.
TIME
SLEEP
SLEEP
SETTING
TEMPERATURE
Sleep Operation button is
pressed
Sleep shift operation
starts
OFF/ON
SLEEP
PM
MODE TEMP. FAN SPEED
MANUAL
SWING
AIR SWING
AUTO
Β°C
11 30:
c
27
h j k
β²
14
ENGLISH
When the remote control cannot be used
Test Run Button.
(Use when installing and moving)
Auto Operation Button.
β When the remote control cannot be
used, press Auto Operation Button to run
Automatic Operation.
(Airflow direction setting will be automatic.)
OFF/ON remote control signal receiving sound
β The Remote Control Signal receiving sound can be omitted as desired.
β To switch OFF the signal receiving sound, press Auto Operation Button for 10 seconds or more. At the
same time, Automatic Operation starts.
(To switch ON, press Auto Operation Button once more for 10 seconds or more.)
β Press Auto Operation Button.
(The operation indication lamp will blink for 20
seconds, and then light up)
βIf the button is pressed once more, the
air conditioner will stop.
(The operation indication lamp will switch
off.)
To set Auto Operation.
β Conο¬rm the power switch is at βIβ (ON).
POWER
ON
OFF
AUTO
OFF/ON
β²
15
Operation Hints
Adjust room temperature properly. Set the
temperature 1Β°C higher than actually desired.
Approximately 10% of electricity costs can be
saved.
Prevent wastage with the Timer. Use Timer
when sleeping or going out to save electricity
cost.
Clean the air filter regularly. Blockage in the air
filter reduces the airflow and lowers the cooling.
Clean at least once every 2 weeks. Otherwise,
about 6% of electricity cost will be wasted.
Do not block the air outlet vents at outdoor unit.
Otherwise, it will lower the cooling perform-
ance.
1Β°C higher
β²
16
ENGLISH
Make sure that the doors and windows are shut.
Otherwise, cooling performance will be reduced
and electricity cost is wasted.
Proper airflow direction adjustment. Set the air-
flow direction louvers horizontal for Cooling
Operation. Operation result will be better.
Keep blinds or curtains closed. Do not let sun-
shine enter the room directly. About 5% of elec-
tricity cost can be saved.
Use insulating material for better performance.
Use insulating material during construction or
renovations. It will save electricity cost.
Cooling
β²
17
Cleaning of front panel (Must be removed before washing)
Cleaning the air conditioner and air filters
Better Care and Maintenance
Do not use water or volatile liquids.
β Do not make air conditioner wet, as there is the danger that it could cause
electric shocks.
Be sure not to apply water when cleaning or at any other time.
β Using water above 40Β°C could cause deformation and/or discolouration.
β Volatile liquids such as thinner or benzene may damage the air condi-
tioner.
Caution
β Clean the air ο¬lters.
β To remove the dust adhering to the filters,
either use a vacuum cleaner, or wash them in
water and dry in the shade.
β Re-insert the filters correctly at the left and right,
with the side marked [FRONT] facing forward.
β Purchase replacement filters from your air con-
ditioner dealer if the air filters become damage.
Air Filter No. CWD00231 (right)
CWD00232 (left)
Regular care and maintenance will extend the life of the air conditioner and prevent wastage of electricity. Before
performing any maintenance procedure, be sure to switch oο¬ the main power supply.
Once every 2 weeks is recommended.
To clean the front panel, gently wash with sponge. Wipe dry or dry in shade.
IMPORTANT: β’ It may lead to shaft damage if the front panel is removed or fixed without releasing the shaft.
β’ Be careful not to drop the front panel.
β Clean the air conditioner.
Wipe gently with a soft, dry cloth.
β To remove front panel.
1. Raise the front panel. 2. Release either one of the fulcrum from the ditch.
Ditch
Press to
the right
Fulcrum
Left side Right side
Fulcrum
Press to
the left
Ditch
3. Release the shaft from
the fixing hole.
β To fix the front panel, reverse the above procedure accordingly.
Press Fixing Hole
Shaft
5. Remove the front panel.
4. Repeat step 2 to release
the other fulcrum.
(
Illustration is shown
)
as above
β²
18
ENGLISH
3
Filters
<Note> β If air purifying filters turn the same colour as the sample colour attached to
the indoor unit within a three month period, replace the filters.
β Re-insert the filters correctly at the left and right with the side marked
[FRONT] facing forward.
β Dusty filters cannot be re-used, even if they are cleaned and washed.
β Purchase replacement filters from your air conditioner dealer.
β Part number for air purifying filters: CZ-SFD50N
β Note:
Catechin is natural brown element. The filter is coated with catechin in
order to prevent the growth of bacteria and viruses.
When not using the air conditioner for a long period
β Are the air outlet
vents and air intake
vents obstructed?
β Is the drain hose
cracked or crushed?
β Are the remote
control batteries in
good condition?
If they are, cooling
performance will drop
and cause problems.
If display is faint or
no display is visible,
the batteries should
be replaced.
! Caution
Be careful not to
hurt your hands on
metal parts.
If it is, leaks will
result.
Remove the air purifying
filters.
Remove the filters from
the filter frame.
Remove the air filters.
Remove the batteries
from the remote control.
2
1
Operate the air condi-
tioner for 2 to 3 hours.
β Type of operation: Fan.
32
1
For air conditioners with a
power plug, stop opera-
tion by remote control and
pull out the power plug.
Note: If the unit is not off by
remote control, the unit
will operate when you
plug in (because
of Auto-restart
Control is provided).
Pre-season inspection (The earlier the better)
Recommended about once every 3 months.
Air filter Air purifying filter
Sample colour
In order to dry out the
internal mechanisms
β Is the discharge air
cold?
If the difference in tem-
perature between the air
outlet vent and air in-
take vent is 8Β°C or more
when cooling, the unit is
normal.
Is cool air coming
out?
Replacement of air purifying filters
β²
19
Troubleshooting
Normal operation
Q Is it okay? A This is the answer.
Air conditioner has been
restarted, but does not
operate for 3 minutes.
This is to protect the air conditioner. Wait until
the air conditioner begins operating.
During Soft Dry Mode
Operation, the air condi-
tioner stops.
The room has a peculiar
odour.
This may be a damp smell exuded by the
walls, carpet, furniture or clothing in the room.
A sound like water ο¬owing
can be heard.
This is the sound of refrigerant ο¬owing inside
the air conditioner unit.
It seems that fog is coming
out from the air condi-
tioner.
Condensation occurs when the airflow from
the air conditioner cools the room air.
During Automatic Airflow
Volume setting, indoor fan
stops occasionally.
This is to remove the smell exuded by the
surroundings.
Soft Dry Mode Operation is a very gentle
Cooling Operation consisting primarily of de-
humidifying. The air conditioner may stop for
approximately 6 minutes in order to prevent
overcooling.
If the room temperature rises again, the
operation will recommence.
Sight
β²
20
ENGLISH
Abnormal operation
The air conditioner
does not operate.
The air conditioner
does not cool eο¬ectively.
Air conditioner operation
noise too loud.
β Has the circuit breaker been tripped?
β Has the power plug been removed from the
wall outlet?
β Is the power switch at βtβ (OFF)?
β Is the Timer being used correctly?
β Has the REMOTE CONTROLLER B β A
switch been set to βBβ?
β Has the temperature been set incorrectly?
β Are the filters dirty?
β Are the intake or outlet vents of the outdoor
unit obstructed?
β Are all windows and doors closed?
β Is the installation work slanted?
β Is the front grille closed properly?
Call the dealer immediately
β Abnormal noise is heard during
operation.
β Water or foreign material
gets into the remote control
by mistake.
β Water leaks from the indoor unit.
If the following conditions occur, immediately turn the power switch to β β (OFF) and unplug.t
β Switches or buttons do not
operate properly.
β The circuit breaker switch-
es off frequently.
β Power supply cord and plug
become unusually warm.
β²
21
! Warning
1) If the supply cord is damaged or need to be replaced, it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
2) Remove power plug or disconnect from the mains before servicing this appliance.
3) Do not repair by yourself.
In case of malfunction of this appliance, do not repair by yourself.
Contact to the sales dealer or service dealer for a repair.
4) The appliance is not intended for use by young children or infirm persons without supervision.
5) Young children should be supervised to ensure that they do not play with the appliance.
6) Turn off the power (Isolation from main power supply).
Pull off the power plug from the receptacle, or switch off the breaker, or switch off the power disconnecting mean
to isolate the equipment from the main power supply in case of an emergency.
! Caution
DISCONNECT THE MAINS PLUG FROM THE SUPPLY SOCKET WHEN NOT IN USE, WHERE SUPPLY
CONNECTION IS VIA MAINS PLUG.
IMPORTANT
1. WHEN THE POWER CORD IS CONNECTED TO THE MAINS THROUGH A MULTI POLAR SWITCH
THERE MUST BE A MULTI POLAR SWITCH (DISCONNECTING MEANS) WITH A MINIMUM 3 mm
CONTACT GAP IN THE FIXED INSTALLATION CIRCUIT.
2. WHEN THE POWER PLUG IS CONNECTED TO THE RECEPTACLE
Replacement or installation of power plugs shall be performed only by authorised/qualified personnels.
The wires in this main lead are coloured in accordance with the following code :
Green-and-yellow : Earth
Blue : Neutral
Brown : Live
If the colours of the wires in the main lead of this appliance do not correspond with the coloured markings
indentifying the terminals in your plug, proceed as follows :
The green-and-yellow wire must be connected to the terminal in the plug which is marked with letter E or by
the earth symbol or coloured green or green-and-yellow.!
The blue wire must be connected to the terminal which is marked with the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.
β²
22
ENGLISH
Please remember to record the following :
βModel Number
βSerial Number
βDealer's Name
βDate Purchased
Note
Matsushita Electric Industrial Co., Ltd.
Osaka 542-8588, Japan.
Printed in Malaysia
P0103-0
F563263
Product specificaties
Merk: | Panasonic |
Categorie: | Airco |
Model: | CS-C242KR |
Heb je hulp nodig?
Als je hulp nodig hebt met Panasonic CS-C242KR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Panasonic
28 December 2024
28 December 2024
28 December 2024
28 December 2024
24 November 2024
24 November 2024
24 November 2024
24 November 2024
24 November 2024
24 November 2024
Handleiding Airco
- Airco Electrolux
- Airco Bosch
- Airco Candy
- Airco Samsung
- Airco Delonghi
- Airco LG
- Airco AEG
- Airco Bauknecht
- Airco BEKO
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Karcher
- Airco Medion
- Airco Remeha
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Vaillant
- Airco Whirlpool
- Airco Zanussi
- Airco Zibro
- Airco Adler
- Airco Airwell
- Airco Akai
- Airco Amana
- Airco Amcor
- Airco Apc
- Airco Arcelik
- Airco Argo
- Airco Balay
- Airco Bartscher
- Airco Bavaria
- Airco Be Cool
- Airco Bestron
- Airco Blaupunkt
- Airco Blumfeldt
- Airco Bodin
- Airco Bomann
- Airco Brandt
- Airco D-Let
- Airco Daikin
- Airco Daitsu
- Airco Defy
- Airco Dimplex
- Airco Dometic
- Airco Domo
- Airco Duracraft
- Airco Duux
- Airco Easy Home
- Airco Eco-De
- Airco Eden
- Airco Edgestar
- Airco Edy
- Airco Einhell
- Airco Emerio
- Airco Emerson
- Airco Eurom
- Airco Everglades
- Airco Evolar
- Airco Exquisit
- Airco Fairland
- Airco Ferroli
- Airco Finlux
- Airco Firstline
- Airco Fral
- Airco Frigidaire
- Airco Frilec
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Fujitsu
- Airco G3 Ferrari
- Airco GE
- Airco General Electric
- Airco GlobalTronics
- Airco Gorenje
- Airco Gree
- Airco Gutfels
- Airco H.Koenig
- Airco Haier
- Airco Hisense
- Airco Hitachi
- Airco Holland Electro
- Airco Home Electric
- Airco Hotpoint
- Airco Hotpoint-Ariston
- Airco HQ
- Airco Hyundai
- Airco Iceberg
- Airco Innoliving
- Airco Insignia
- Airco Itho
- Airco Kalorik
- Airco Kelvinator
- Airco Kenmore
- Airco Klarstein
- Airco Koenic
- Airco Kogan
- Airco Korona
- Airco Lanaform
- Airco Lavorwash
- Airco Livington
- Airco Livoo
- Airco Logik
- Airco Magnavox
- Airco Maiko
- Airco Manta
- Airco Master
- Airco Maxicool
- Airco Meaco
- Airco Meireles
- Airco Melissa
- Airco Mesko
- Airco Mestic
- Airco Midea
- Airco Mistral
- Airco Mitsubishi
- Airco Moa
- Airco MPM
- Airco MundoClima
- Airco Nabo
- Airco Nedis
- Airco Philco
- Airco Prem-i-air
- Airco Primo
- Airco Princess
- Airco Profile
- Airco Progress
- Airco Proklima
- Airco Proline
- Airco Protector
- Airco Qlima
- Airco RCA
- Airco REMKO
- Airco Rotel
- Airco Rowenta
- Airco Royal Sovereign
- Airco Russell Hobbs
- Airco Sanyo
- Airco Sauber
- Airco Saunier Duval
- Airco Sencor
- Airco Sencys
- Airco Sharp
- Airco Sigma
- Airco SMC
- Airco Sonnenkonig
- Airco SPT
- Airco Starlyf
- Airco Stirling
- Airco Suntec
- Airco Tarrington House
- Airco Taurus
- Airco TCL
- Airco Team
- Airco Technisat
- Airco Teco
- Airco Tectro
- Airco Telefunken
- Airco Termozeta
- Airco Theben
- Airco Thomson
- Airco Tomado
- Airco Tosot
- Airco Toyotomi
- Airco Trilec
- Airco Tristar
- Airco Tronix
- Airco Trotec
- Airco Truma
- Airco Ufesa
- Airco Vestel
- Airco Vivax
- Airco Waeco
- Airco Westinghouse
- Airco White Knight
- Airco Whynter
- Airco Woods
- Airco Zelmer
- Airco Jocca
- Airco Jocel
- Airco Just Fire
- Airco OK
- Airco Olimpia Splendid
- Airco OneConcept
- Airco Oregon Scientific
- Airco Ozito
- Airco Becken
- Airco Black And Decker
- Airco Camry
- Airco Clatronic
- Airco Concept
- Airco ECG
- Airco Elba
- Airco Essentiel B
- Airco Guzzanti
- Airco Heinner
- Airco Khind
- Airco Orbegozo
- Airco Profilo
- Airco Trisa
- Airco Vox
- Airco Wilfa
- Airco Anslut
- Airco Kunft
- Airco Soler And Palau
- Airco Conrad
- Airco Ansonic
- Airco Aspes
- Airco Comfee
- Airco CorberΓ³
- Airco Danby
- Airco Equator
- Airco Esatto
- Airco IFB
- Airco Infiniton
- Airco Koldfront
- Airco Listo
- Airco Orima
- Airco Svan
- Airco Ardes
- Airco Eldom
- Airco Premium
- Airco Teesa
- Airco Alpatec
- Airco ElectriQ
- Airco Heylo
- Airco HTW
- Airco Prime3
- Airco Avidsen
- Airco SereneLife
- Airco DCG
- Airco Kubo
- Airco Malmbergs
- Airco Challenge
- Airco Calor
- Airco Riffel
- Airco Broan
- Airco RIDGID
- Airco KDK
- Airco Bimar
- Airco Climadiff
- Airco Tripp Lite
- Airco Mabe
- Airco Equation
- Airco Godrej
- Airco Milectric
- Airco Orava
- Airco Simplicity
- Airco Cecotec
- Airco Baxi
- Airco Thermex
- Airco Keystone
- Airco Sanus
- Airco Carrier
- Airco Furrion
- Airco Rinnai
- Airco Carson
- Airco Artrom
- Airco Carrefour Home
- Airco CΓ©liera
- Airco Commercial Cool
- Airco Coolix
- Airco Hokkaido
- Airco Kibernetik
- Airco Norpole
- Airco Senville
- Airco SHE
- Airco CyberPower
- Airco Perfect Aire
- Airco Be Quiet!
- Airco Ariston Thermo
- Airco Element
- Airco Dantherm
- Airco Argoclima
- Airco Heller
- Airco DEXP
- Airco Chigo
- Airco Elgin
- Airco Evapolar
- Airco EcoFlow
- Airco Liebert
- Airco Avalon Bay
- Airco NewAir
- Airco Braemar
- Airco ActronAir
- Airco Klimaire
- Airco Consul
- Airco SEEGER
- Airco LERAN
- Airco Friedrich
- Airco Aerian
- Airco Polocool
- Airco Convair
- Airco Companion
- Airco Volteno
- Airco Arcoaire
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Monzana
- Airco Kaden
- Airco Geist
- Airco GoldAir
- Airco SΓ΄lt
- Airco Avallon
- Airco Ravanson
- Airco Create
- Airco Columbia Vac
- Airco TURBRO
- Airco House & Luft
- Airco Daizuki
- Airco Bonaire
- Airco Evapcool
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Quirky
- Airco Krone
- Airco KwiKool
- Airco Big Ass Fans
- Airco Arctic King
- Airco Omega Altise
- Airco Climachill
- Airco Heat Controller
- Airco Luma Comfort
- Airco AireMax
- Airco Kaco
- Airco Middle Atlantic
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco Electroline
- Airco BLUEPALM
- Airco KuulAire
- Airco Cool-Space
- Airco BOSFOR
- Airco Aconatic
- Airco VΓ€nEE
- Airco Mayer
- Airco Yamazen
- Airco Corona
- Airco Symphony
- Airco Soler & Palau
- Airco Universal Blue
Nieuwste handleidingen voor Airco
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025
7 Januari 2025