- 1 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
2.3-4.0 m
(7.6-13 ft.)
INSTALLATION AND MAINTENANCE NOTES
Warning Caution
Never repair or
modify product
Hold the main unit
securely when you
install or service it.
If you remove your
hands from the main
unit when cables are
connected to it, the
main unit may fall
and the connector
cables may break
or the circuit board
may be damaged.
Caution
Verify that the
power is off before
connecting the
wiring.
2
PARTS IDENTIFICATION
1
No.59-1545-1 0905-01
INSTALLATION INSTRUCTIONS
Synthesized Intelligent PIR
REDWALL-V series
FEATURES
* Intelligent PIR Detection System
- Detection of ambient temperature and illuminance for automatic
sensitivity management
- Advanced detection algorithm
- Double Dual/One Quad pryo-elements with patented Double
Conductive Shielding for main area
* Built-in creep zone detector (Double dual pyro-elements)
* Anti-vandalism functions
- Anti-rotation function with 3-axis accelerometer
- Anti-masking function with photo-beam
- Reinforced polycarbonate housing
- Max. 4 m (13 ft.) installation height
* Independent sensitivity selector for creep/near/far areas
* Independent N.C. and N.O. output for main area SIP-5030
* 2 x N.C. and N.O. independent output for main areas (Near and
Far areas ) SIP-100
* Adjustable alarm interval time
REDWALL-V
: Synthesized Intelligent PIR with creep zone
SIP-5030
SIP-100
•
•
Mount the detector so that the majority of trafc ow is across the detection pattern.
*1: Not used for the SIP-100.
2-1
INSTALLATION HINTS
Base
Fixing screw
for the base Main unit
Masking plate for
near area (*1)
Fixing rubber
form (*1)
Window
Fixing screw
for the cover
Cover
Far area mirror
Adjustment screws
(two facing each other)
Angle adjustment guide
Near area mirror
Arrow marking
Fixing screw
Nylon wire
loop
When servicing, the sensor
can be hooked onto the
base using the nylon wire
loop.
Creep unit
Synthesized Intelligent PIR
REDWALL-V series
- 2 -
3-1
Wall Mounting
Attach the paper template (an accessory) onto the wall,
and drill a 6-mm dia. mounting hole and a cabling hole.
Insert the anchor bolt (an accessory) into the board mount
hole.
Using an allen key, remove the main unit from the base.
Drill through the bushing of the wiring hole, pass the cable
through the hole, and secure the base to the wall.
Connect the cable to the terminal block (see Step 3-3).
Mount the main unit onto the base.
Cautions>>
When mounting the main unit, take care not to trap the
nylon wire loop. Also, take care not to get your fingers
caught.
Check to see that the various settings and operations are
correct.
Caution>>
When the red LED flashes after the power turns on,
this signifies that the system is warming up. Wait for
approximately 60 seconds.
INSTALLATION AND ANGLE ADJUSTMENT
3
(1)
(2)
(3)
(4)
(5)
(6)
3-2
Inside View of the Base
3-3
WIRING
*1: TAMPER terminals to be connected to a 24 hour supervisory loop.
*2: FAR AREA ALARM OUTPUT, when the NUMBER OF OUTPUTS select switch is
ON(3) (see Step 5-3).
*3: Both FAR AREA and NEAR AREA ALARM OUTPUT, when the NUMBER OF
OUTPUTS select switch is OFF(2).
And Only NEAR AREA ALARM OUTPUT, when the NUMBER OF OUTPUTS
select switch is ON(3) (see Step 5-3).
Name Function
TROUBLE
OUTPUT
Trouble out is used for anti-masking signal. When
an object is placed close to the lens surface, for a
period of more than 20 seconds (approx.), the IR
anti-masking circuit will activate and generate a
trouble signal.
TAMPER
OUTPUT
It is detected when the cover is opened.
It is detected when the main unit is removed from
its base.
Anti-Rotation:
Damage sustained by the main unit is detected.
When the system power switch is turned on while
the cover is closed, the mounting position of the
main unit itself will be determined and stored in
memory after approximately 10 seconds. Then,
if the main unit is impacted in a horizontal or
vertical direction and if the position of the main
unit has changed, damage sustained by the main
unit will be detected. However, if you remove the
cover while keeping the system power turned on,
and if you close the cover again after correcting
the position of the main unit, the new position
of the main unit will be stored in memory after
approximately 10 seconds.
Waterproof seal
(Do not remove
this seal.)
Base
Bushing of wiring
hole
Open wiring cap
Main unit connector
Wall mounting hole
Wiring terminals
(SIP-100 ONLY)
Wall mounting hole
Bushing of wiring
hole
Wiring terminals
1 Loosen the
xing screw
for the
base.
2 Open.
3 Unplug
the cable
connector.
4 Pull out.
POWER INPUT
TAMPER OUTPUT *1
FAR AREA AND NEAR AREA *3
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
TROUBLE
OUTPUT
SPARE
4 Tighten and
secure the
xing screw
for the base.
2 Connect the
connector.
3 Close.
1 Insert and
secure here.
Nylon
wire
loop
Distance from the ground to
the bottom of the template
must be between 2.3 m (7.6 ft.)
and 4 m (13 ft.).
CREEP
ALARM OUTPUT
(N.C.)
ALARM OUTPUT
(N.O.)
FAR AREA *2
ALARM OUTPUT (N.C.)
ALARM OUTPUT (N.O.)
(SIP-100 only)
- 3 -
ENGLISH FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
DETECTION AREA SETTING
You can adjust the detection area by 90 degrees in a horizontal
direction and by 10 degrees in a vertical direction.
Correct the vertical detection angle according to the mounting
height of the sensor unit.
Applicable
models
SIP-5030 SIP-100
10°
10°
85° 85°
Cautions>>
To rotate the main unit counterclockwise, loosen the
RHside adjustment screw. To rotate the main unit
clockwise, loosen the LH-side adjustment screw.
Otherwise, you may find it difficult to tighten or you may
find that you cannot tighten the adjustment screw when
you are securing the main unit.
To rotate the unit counterclockwise
To rotate the unit clockwise
4-1
Main Detection Area Setting
Adjust the angle of the main unit in a horizontal direction so
that you can cover the desired detection area.
4
Power wires should not exceed the following lengths.
WIRE SIZE SIP-5030 SIP-100
12V DC 14V DC 24V AC 12V DC 14V DC 24V AC
0.33 mm2
(AWG22)
480
(1570)
640
(2100)
1370
(4490)
410
(1350)
550
(1800)
1280
(4200)
0.52 mm2
(AWG20)
760
(2490)
1010
(3310)
2160
(7090)
650
(2130)
860
(2820)
2020
(6630)
0.83 mm2
(AWG18)
1210
(3970)
1610
(5280)
3450
(11320)
1030
(3380)
1380
(4530)
3220
(10560)
m (ft.)
Adjust the angle of the main unit in a vertical direction so
that you can cover the desired detection area.
Cautions>>
If the mounting wall is at an angle, the arrow of the
main unit may exceed the top or bottom limit of “Angle
adjustment guide”. Always check this using the area
viewfinder or the walk tester. If the detection area is too
high or too low, an object outside the detection area may
be detected or incorrect object detection may occur.
Remove the cover.
Cautions>>
The cover is linked to the main unit by nylon wire loop so
that the cover does not fall. Do not pull the cover using
excessive force.
Mount the area viewfinder.
F2 F3 F4 F5
E2 E3 E4 E5
D1 D2
D3D 4
D5 D6
C1 C2 C3 C4 C5 C6
B1
B2 B3B4
B5
78910
123456
F1 F6
E1 E6
B6
50 30 (521 20 6)
(2)
(3)
(4)
(1)
Hooks
3 Slide the cover downward
and release the hooks.
1 Loosen two xing screws for
the cover and pull out the
cover until it stops.
Cover
2 Hold the heads of both cover xing screws
with your hands, and pull down and remove
the bottom section of the cover from the
main unit.
Adjustment
screw
3 Rotate the main unit.
2 Loosen the adjustment screw.
4 Tighten the adjustment screw slightly.
1 Loosen the xing
screw for the base.
Area plate
(an accessory)
Determine the
detection direction
(see Step 5- ).1
Put the red string
round the main unit.
Insert and
mount to
the main
unit.
Red string to
hold the main unit
Center circle
of the lens
Area viewnder AVF-1 (optional)
Inspection window
Insert the area
plate into the slot.
* Peel off the
protection
seal from
both faces
of the area
plate.
1
2
3
4
When mounted at a height of
2.3 meters (7.6ft.)
When mounted at a height of
4.0 meters (13ft.)
Align the arrow of the main
unit with the “Angle adjustment
g u i d e ” o f t he a d j u s t m e n t
screw. The main unit is usually
adjusted within the width of this
guide.
Product specificaties
Merk: | Optex |
Categorie: | Detector |
Model: | SIP-404-IP-BOX |
Heb je hulp nodig?
Als je hulp nodig hebt met Optex SIP-404-IP-BOX stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Detector Optex
13 December 2023
13 November 2023
30 Mei 2023
7 Mei 2023
14 April 2023
8 April 2023
18 Maart 2023
15 Februari 2023
10 Februari 2023
8 Februari 2023
Handleiding Detector
- Detector Bosch
- Detector Garmin
- Detector Gigaset
- Detector Honeywell
- Detector Pioneer
- Detector Abus
- Detector Alecto
- Detector Amprobe
- Detector AngelEye
- Detector Astralpool
- Detector Axis
- Detector Beha-Amprobe
- Detector Brennenstuhl
- Detector BRK
- Detector Denver
- Detector Dometic
- Detector Duro
- Detector Ebode
- Detector Elro
- Detector Extech
- Detector Ferguson
- Detector Ferrex
- Detector FireAngel
- Detector Flir
- Detector Fluke
- Detector Gamma Scout
- Detector Gossen
- Detector Grothe
- Detector Hager
- Detector Hikvision
- Detector Iget
- Detector Konig
- Detector Laserliner
- Detector Maginon
- Detector Marquant
- Detector Mercury
- Detector Metrix
- Detector National Geographic
- Detector Nedis
- Detector Netatmo
- Detector PCE Instruments
- Detector Powerfix
- Detector Pyle
- Detector Royal Sovereign
- Detector Sanwa
- Detector Satel
- Detector Siedle
- Detector Silverline
- Detector Skil
- Detector Smartwares
- Detector Steinel
- Detector Techno Line
- Detector Toolcraft
- Detector Trotec
- Detector Uniden
- Detector V-Tac
- Detector Velleman
- Detector Voltcraft
- Detector X4-Tech
- Detector Xavax
- Detector Joy-it
- Detector Jung
- Detector Olympia
- Detector Black And Decker
- Detector Schwaiger
- Detector Soler And Palau
- Detector Safescan
- Detector Cobra
- Detector Sauter
- Detector Sun Joe
- Detector Techly
- Detector DSC
- Detector Fisher
- Detector Garrett
- Detector Genie
- Detector Tripp Lite
- Detector Nexa
- Detector EVOLVEO
- Detector Whistler
- Detector Vemer
- Detector Ei Electronics
- Detector FireX
- Detector GEV
- Detector AcuRite
- Detector Testo
- Detector System Sensor
- Detector Testboy
- Detector IFM
- Detector Kyoritsu
- Detector Dahua Technology
- Detector Busch-Jaeger
- Detector Popp
- Detector Homematic IP
- Detector X-Sense
- Detector Kreator
- Detector ORNO
- Detector Multimetrix
- Detector Vimar
- Detector Escort
- Detector ZKTeco
- Detector Inovonics
- Detector Guardian Avionics
- Detector Thitronik
- Detector Cavius
- Detector Chauvin Arnoux
- Detector Pentatech
- Detector Flow Smoke Detector
- Detector Benewake
- Detector BeeSecure
- Detector Resideo
- Detector SureCall
- Detector Schabus
- Detector Zircon
- Detector STI
- Detector HT Instruments
- Detector BlendMount
- Detector K40
- Detector Gewiss
- Detector Seco-Larm
- Detector Seaward
- Detector Silent Knight
- Detector S.E. International
- Detector Rocky Mountain
- Detector Skyscan
- Detector Bearware
- Detector Winland
- Detector Noyafa
Nieuwste handleidingen voor Detector
3 December 2024
30 November 2024
18 November 2024
17 November 2024
17 November 2024
16 November 2024
16 November 2024
15 November 2024
15 November 2024
15 November 2024