Neff I94CAQ6N0B Handleiding

Neff Afzuigkap I94CAQ6N0B

Lees hieronder de 📖 handleiding in het Nederlandse voor Neff I94CAQ6N0B (24 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
Ceiling-mounted ventilation system
[en]
I94CAQ6N0B
I94CAQ6N0B
I94CAQ6N0B
I94CAQ6N0BI94CAQ6N0B
en Safety
2
Table of contents
Safety............................................................................2
Preventing material damage .......................................4
Environmental protection and saving energy............5
Operating modes .........................................................5
Familiarising yourself with your appliance ................6
Before using for the first time .....................................6
Basic operation ............................................................6
Hob-based hood control..............................................8
HomeConnect .............................................................9
Cleaning and servicing..............................................10
Troubleshooting.........................................................12
Customer Service.......................................................13
Accessories................................................................14
Disposal......................................................................14
Installation instructions.............................................15
Safety
Please read the safety information to ensure
that you use the appliance safely.
General information
You can find general information about this in-
struction manual here.
¡Read this instruction manual carefully. Only
this will ensure you use the appliance
safely and efficiently.
¡This manual is intended for the installer and
the user of the appliance.
¡Follow the safety instructions and warnings.
¡Keep the instruction manual and the
product information safe for future refer-
ence or for the next owner.
¡Check the appliance after unpacking it. Do
not connect the appliance if it has been
damaged in transit.
Intended use
Read the information on intended use to en-
sure that you use the appliance correctly and
safely.
The appliance can only be used safely if it is
correctly installed according to the safety in-
structions. The installer is responsible for en-
suring that the appliance works perfectly at its
installation location.
Only use this appliance:
¡In accordance with these instructions for in-
stallation and use.
¡In private households and in enclosed
spaces in a domestic environment.
¡Up to an altitude of max. 2000m above
sea level.
Do not use the appliance:
¡With an external timer.
Restriction on user group
Avoid risks to children and vulnerable per-
sons.
This appliance may be used by children aged
8 or over and by people who have reduced
physical, sensory or mental abilities or inad-
equate experience and/or knowledge,
provided that they are supervised or have
been instructed on how to use the appliance
safely and have understood the resulting
dangers.
Children must not play with the appliance.
Children must not perform cleaning or user
maintenance unless they are at least 15 years
old and are being supervised.
Keep children under the age of 8 years away
from the appliance and power cable.
Safe use
Follow these safety instructions when using
the appliance.
WARNING‒Risk of suffocation!
Children may put packaging material over
their heads or wrap themselves up in it
and suffocate.
â–¶
â–¶
â–¶
▶▶ Keep packaging material away from
children.
â–¶
â–¶
â–¶
▶▶ Do not let children play with packaging
material.
WARNING‒Risk of poisoning!
Risk of poisoning from flue gases being
drawn back in. Room-air-dependent heat-
producing appliances (e.g. gas, oil, wood
or coal-operated heaters, continuous flow
heaters or water heaters) obtain combus-
tion air from the room in which they are
installed and discharge the exhaust gases
into the open through an exhaust gas sys-
Safety en
3
tem (e.g. a chimney). With the extractor
hood switched on, air is extracted from
the kitchen and the adjacent rooms.
Without an adequate supply of air, the air
pressure falls below atmospheric pres-
sure. Toxic gases from the flue or the ex-
traction shaft are sucked back into the liv-
ing space.
â–¶
â–¶
â–¶
▶▶ Always ensure adequate fresh air in the
room if the appliance is being operated
in exhaust air mode at the same time
as a room air-dependent heat-produ-
cing appliance is being operated.
â–¶
â–¶
â–¶
▶▶ It is only possible to safely operate the
appliance if the pressure in the room in
which the heating appliance is installed
does not drop more than
4Pa(0.04mbar) below atmospheric
pressure. This can be achieved
whenever the air needed for combus-
tion is able to enter through openings
that cannot be sealed, for example in
doors, windows, in conjunction with in-
coming/exhaust air wall boxes or by
other technical means. An incoming/
exhaust air wall box alone does not en-
sure compliance with the limit.
â–¶
â–¶
â–¶
▶▶ In any case, consult your responsible
chimney sweep. They are able to as-
sess the house's entire ventilation
setup and will suggest the suitable
ventilation measures to you.
â–¶
â–¶
â–¶
▶▶ Unrestricted operation is possible if the
appliance is operated exclusively in air
recirculation mode.
WARNING‒Risk of fire!
¡Fatty deposits in the grease filters may
catch fire.
â–¶
â–¶
â–¶
▶▶ Never operate the appliance without a
grease filter.
â–¶
â–¶
â–¶
▶▶ Clean the grease filters regularly.
â–¶
â–¶
â–¶
▶▶ Never work with naked flames close to
the appliance (e.g. flambéing).
â–¶
â–¶
â–¶
▶▶ Do not install the appliance near a
solid fuel heating appliance (e.g. wood-
or coal-burning) unless the heating ap-
pliance has a sealed, non-removable
cover. There must be no flying sparks.
¡Hot oil or grease ignites very quickly.
â–¶
â–¶
â–¶
▶▶ Always supervise hot oil and fat.
â–¶
â–¶
â–¶
▶▶ Never extinguish burning oil or fat with
water. Switch off the cooking zone. Ex-
tinguish flames carefully using a lid, fire
blanket or something similar.
¡When gas burners are in operation
without any cookware placed on them,
they can build up a lot of heat. A ventila-
tion appliance installed above the cooker
may become damaged or catch fire.
â–¶
â–¶
â–¶
▶▶ Only operate the gas burners with
cookware on them.
¡Gas burners can build up a lot of heat
while operating. A ventilation appliance in-
stalled above the cooker may become
damaged or catch fire.
â–¶
â–¶
â–¶
▶▶ Only operate the gas burners with
cookware on them.
â–¶
â–¶
â–¶
▶▶ Set at least fan setting 3.
â–¶
â–¶
â–¶
▶▶ Never operate large burners of more
than 5kW with the highest flame for
longer than 15minutes, e.g. a wok.
WARNING‒Risk of burns!
¡The accessible parts of the appliance be-
come hot during operation.
â–¶
â–¶
â–¶
▶▶ Never touch these hot parts.
â–¶
â–¶
â–¶
▶▶ Keep children at a safe distance.
¡The appliance will become hot during op-
eration.
â–¶
â–¶
â–¶
▶▶ Allow the appliance to cool down be-
fore cleaning it.
WARNING‒Risk of injury!
¡Components inside the appliance may
have sharp edges.
â–¶
â–¶
â–¶
▶▶ Carefully clean the appliance interior.
¡Items placed on the appliance may fall
off.
â–¶
â–¶
â–¶
▶▶ Do not place any objects on the appli-
ance.
¡Changes to the electrical or mechanical
assembly are dangerous and may lead to
malfunctions.
â–¶
â–¶
â–¶
▶▶ Do not make any changes to the elec-
trical or mechanical assembly.
¡The filter cover may swing out.
â–¶
â–¶
â–¶
▶▶ Open the filter cover slowly.


Product specificaties

Merk: Neff
Categorie: Afzuigkap
Model: I94CAQ6N0B
Kleur van het product: Roestvrijstaal
Ingebouwd display: Ja
Gewicht: 20300 g
Breedte: 900 mm
Diepte: 500 mm
Netbelasting: 204 W
Snoerlengte: 1.3 m
Geluidsniveau: 61 dB
Energie-efficiëntieklasse: B
Jaarlijks energieverbruik: 35 kWu
Soort: Plafond inbouw
Motor vermogen: 190 W
Uitlaat aansluiting diameter: 150 mm
Illuminance: 659 Lux
Maximale afzuigcapaciteit: 434 m³/uur
Afzuigmethode: Afvoerend/recirculerend
Fluid dynamic efficiency class: A
Verlichtingefficiëntieklasse: A
Vetfilterefficiëntieklasse: E
Minimale afstand van electrische hob: 650 mm
Minimale afstand van gas hob: 650 mm
Aantal lampen: 4 gloeilamp(en)
Type lamp: LED
Soort vetfilter: Aluminium/Roestvrij staal
Wasbaar filter: Ja
Hoogte (min): 189 mm
Hoogte (max): 189 mm
Geluidsniveau (hoge snelheid: 61 dB
Maximum hercirculeringsvermogen: 434 m³/uur
Aantal filters: 2 stuk(s)
Installatie compartiment breedte: 888 mm
Installatie compartiment diepte: 487 mm
Aantal snelheden: 3
Geluidsniveau (hercirculatie modus): 61 dB
Verlichtingspositie: Zijkant
Intensieve stand: Ja
Geluidsniveau (intensieve snelheid): 72 dB
Dimbare verlichting: Ja
Vaatwasserbestendig filter: Ja
Druk (Pa): 248
Stroomverbruik (in standby): 0.32 W
Kleurtemperatuur: 3500 K
Afstandsbediening inbegrepen: Ja
AC-ingangsspanning: 220-240 V
AC-ingangsfrequentie: 50/60 Hz
Type beeldscherm: LED
Energie-efficiëntieschaal: A+++ tot D
Indicator filterreiniging: Ja

Heb je hulp nodig?

Als je hulp nodig hebt met Neff I94CAQ6N0B stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Neff

Neff

Neff DBBC620N Handleiding

14 November 2024
Neff

Neff ICBS958W Handleiding

14 November 2024
Neff

Neff DBMP655N Handleiding

14 November 2024
Neff

Neff DMK651IHM2 Handleiding

14 November 2024
Neff

Neff DMK951FRM1 Handleiding

21 Februari 2024
Neff

Neff DML5766N Handleiding

21 Februari 2024
Neff

Neff DLAA600W Handleiding

21 Februari 2024
Neff

Neff DFHP951S Handleiding

21 Februari 2024
Neff

Neff DIKP951S Handleiding

21 Februari 2024
Neff

Neff D65IFN1S0B Handleiding

11 Januari 2024

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap