ioLogik E1200 Series User’s Manual
Tenth Edition, April 2013
www.moxa.com/product
© 2013 Moxa Inc. All rights reserved.
Reproduction without permission is prohibited.
ioLogik E1200 Series User’s Manual
The software described in this manual is furnished under a license agreement and may be used only in accordance with
the terms of that agreement.
Copyright Notice
Copyright ©2013 Moxa Inc.
All rights reserved.
Reproduction without permission is prohibited.
Trademarks
The MOXA logo is a registered trademark of Moxa Inc.
All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
Information in this document is subject to change without notice and does not represent a commitment on the part of
Moxa.
Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited
to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the
products and/or the programs described in this manual, at any time.
Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for
its use, or for any infringements on the rights of third parties that may result from its use.
This product might include unintentional technical or typographical errors. Changes are periodically made to the
information herein to correct such errors, and these changes are incorporated into new editions of the publication.
Technical Support Contact Information
www.moxa.com/support
Moxa Americas
Toll
- free: +1- - -888 669 2872
Tel:
- - -+1 714 528 6777
Fax:
- - -+1 714 528 6778
Moxa China (Shanghai office)
Toll
- free: +86 800 820 5036- - -
Tel:
- - - +86 21 5258 9955
Fax:
- - -+86 21 5258 5505
Moxa Europe
Tel:
- - -0 +49 89 3 70 03 99
Fax: - - -+49 89 3 70 03 99 99
Moxa Asia
-Pacific
Tel:
-2- - +886 8919 1230
Fax: -2- -+886 8919 1231
Moxa India
Tel:
- - - +91 80 4172 9088
Fax:
- - -+91 80 4132 1045
Table of Contents
1. Introduction ...................................................................................................................................... 1-1
Product Features ................................................................................................................................ 1-2
Inside the Box .................................................................................................................................... 1-2
Product Model Information ................................................................................................................... 1-3
Product Specifications ......................................................................................................................... 1-4
Common Specifications ................................................................................................................ 1-4
ioLogik E1210 ............................................................................................................................. 1-5
ioLogik E1211 ............................................................................................................................. 1-5
ioLogik E1212 ............................................................................................................................. 1-6
ioLogik E1213 ............................................................................................................................. 1-7
ioLogik E1214 ............................................................................................................................. 1-8
ioLogik E1240 ............................................................................................................................. 1-9
ioLogik E1241 ............................................................................................................................. 1-9
ioLogik E1242 ........................................................................................................................... 1-10
ioLogik E1260 ........................................................................................................................... 1-11
ioLogik E1262 ........................................................................................................................... 1-11
Physical Dimensions .......................................................................................................................... 1-12
Hardware Reference .......................................................................................................................... 1-13
Panel Guide .............................................................................................................................. 1-13
Ethernet Port ............................................................................................................................ 1-13
LED Indicators .......................................................................................................................... 1-13
I/O Circuit Diagram ........................................................................................................................... 1-14
DI Circuit ................................................................................................................................. 1-14
Sinking DO Circuit ..................................................................................................................... 1-14
Sourcing DO Circuit ................................................................................................................... 1-15
DIO Circuit ............................................................................................................................... 1-16
Relay Circuit ............................................................................................................................. 1-17
AI Circuit .................................................................................................................................. 1-17
RTD Circuit ............................................................................................................................... 1-18
TC Circuit ................................................................................................................................. 1-18
2. Initial Setup ...................................................................................................................................... 2-1
Hardware Installation .......................................................................................................................... 2-2
Connecting the Power .................................................................................................................. 2-2
Grounding the ioLogik E1200 ........................................................................................................ 2-2
DIN Rail, Wall Mounting ............................................................................................................... 2-2
Connecting to the Network ........................................................................................................... 2-3
Jumper Settings (DIO and AI) ....................................................................................................... 2-3
DIO Mode Configuration Settings ........................................................................................... 2-4
AI Mode Configuration Settings .............................................................................................. 2-4
EXT Power Configuration Settings (ioLogik E1213 Only) ............................................................ 2-4
I/O Wiring Diagrams .................................................................................................................... 2-5
ioSearchâ„¢ Installation ......................................................................................................................... 2-7
Load Factory Default Settings ............................................................................................................... 2-7
3. Using the Web Console ...................................................................................................................... 3-1
Introduction to the Web Console ........................................................................................................... 3-2
Overview ........................................................................................................................................... 3-3
Network Settings for the Web Console ................................................................................................... 3-4
General Settings ......................................................................................................................... 3-4
Ethernet Configuration ................................................................................................................. 3-4
User- Defined Modbus Addressing.......................................................................................................... 3-5
Default Modbus Address ............................................................................................................... 3-5
Active OPC Server Settings .................................................................................................................. 3-6
Tag Generation ................................................................................................................................... 3-6
I/O Settings ....................................................................................................................................... 3-8
DI Channels ................................................................................................................................ 3-8
DO Channels ............................................................................................................................. 3-10
AI Channels .............................................................................................................................. 3-11
AI Input Range ......................................................................................................................... 3-12
AO Channels ............................................................................................................................. 3-14
RTD Channels ........................................................................................................................... 3-15
TC Channels ............................................................................................................................. 3-17
System Management ......................................................................................................................... 3-18
Accessibility IP List .................................................................................................................... 3-18
Network Connection................................................................................................................... 3-19
Firmware Update ....................................................................................................................... 3-19
Import System Configuration Settings ......................................................................................... 3-19
Export System Settings .............................................................................................................. 3-20
Peer- - 3-to Peer Networking.................................................................................................................... 20


Product specificaties

Merk: Moxa
Categorie: Wifi-repeater
Model: ioLogik E1260
Kleur van het product: Zilver
Gewicht: 200 g
Breedte: 27.8 mm
Diepte: 84 mm
Hoogte: 124 mm
Soort: Netwerkzender & -ontvanger
LED-indicatoren: Ja
Stroom: 0.110 A
Aantal Ethernet LAN (RJ-45)-poorten: 2
Certificering: UL/cUL Class I Division 2, ATEX Zone 2
Bekabelingstechnologie: 10/100Base-T(X)
Temperatuur bij opslag: -40 - 85 °C
Bedrijfstemperatuur, bereik: -40 - 167 °F
Mean time between failures (MTBF): 660260 uur
Hoogte, in bedrijf: 0 - 2000 m
Maximaal bereik: - m
AC-ingangsspanning: 24 V
Bedrijfstemperatuur (T-T): -40 - 75 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 95 procent