Notes for the Reader
WARNING
Indicates that death or personal injury may occur if proper
precautions are not taken.
ATTENTION
Indicates that possible damage to this product or your property
may result if proper precautions are not taken.
NOTE
H ighlights important information related to this product.
Package Checklist
Moxa’s AWK- 4131 is shipped with the following items. If any of these
items is missing or damaged, please contact your customer service
representative for assistance.
AWK- 4131
2 omni- - directional antennas (5/2 dBi, N type male, 2.4/5 GHz)
Wall mounting kit
Field- installable power plug
Field- - installable M12 8 pin male plug for Ethernet
Metal cap to cover M12 male DI/O connector
Metal cap to cover RJ45 connector
Meta cap to cover M30 SFP connector
Documentation and software CD
Quick installation guide (printed)
Warranty card
Recommended SFP Accessories
SFP-1G series
SFP- 1GSXLC:
Small form factor pluggable transceiver with 1000BaseSX, LC, 0.5 km,
0 to 60°C
SFP- - 1GSXLC T:
Small form factor pluggable transceiver with 1000BaseSX, LC, 0.5 km,
- 20 to 75°C
SFP- 1GLSXLC:
Small form factor pluggable transceiver with 1000BaseLSX, LC, 2 km,
0 to 60°C
SFP- - 1GLSXLC T:
Small form factor pluggable transceiver with 1000BaseLSX, LC, 2 km,
- 40 to 85°C
SFP- 1GLXLC:
Small form factor pluggable transceiver with 1000BaseLX, LC, 10 km,
0 to 60°C
- - 3
SFP- - 1GLXLC T:
Small form factor pluggable transceiver with 1000BaseLX, LC, 10 km,
- 40 to 85°C
SFP- 1GLHLC:
Small form factor pluggable transceiver with 1000BaseLH, LC, 30 km,
0 to 60°C
SFP- - 1GLHLC T:
Small form factor pluggable transceiver with 1000BaseLH, LC, 30 km,
- 40 to 85°C
SFP- 1GLHXLC:
Small form factor pluggable transceiver with 1000BaseLHX, LC, 40
km, 0 to 60°C
SFP- - 1GLHXLC T:
Small form factor pluggable transceiver with 1000BaseLHX, LC, 40
km, - 40 to 85°C
SFP- 1GZXLC:
Small form factor pluggable transceiver with 1000BaseZX, LC, 80 km,
0 to 60°C
SFP- - 1GZXLC T:
Small form factor pluggable transceiver with 1000BaseZX, LC, 80 km,
- 40 to 85°C
SFP- 1GEZXLC:
Small form factor pluggable transceiver with 1000BaseEZX, LC, 110
km, 0 to 60°C
SFP- - 1GEZXLC 120:
Small form factor pluggable transceiver with 1000BaseEZX, LC, 120
km, 0 to 60°C
NOTE
The above items come with the AWK- 4131
standard version. The
package contents for customized versions may different.be
Installation
Before installing the AWK-4131, make sure that all items in the Package
Checklist are in the box. In addition, you will need access to a notebook
computer or PC equipped with an Ethernet port. The AWK- 4131 has a
default IP address, user name and password that you must use when
resetting or connecting to your AWK- 4131 device.
Default IP address: 192.168.127.253
User name: admin
Password: root
Please read Chapter2 Getting Startedin AWK- 4131 Users Manual for
more details about installation and configuration.
ATTENTION
For security reasons, we strongly recommend changing the
password. To do so, go to Maintenance
Password
, and then
follow the on- screen instructions.
- - 4
NOTE
To make the change effective, you must save the change and
then click Restart
Save and Restart button to apply all
changes.
Panel Layout of the AWK- 4131
1. Main antenna A.
2. Main antenna B.
3. LEDs for PWR, FAULT,
STATE, WLAN and LAN.
4. M12 A-coding connector
for PWR1 and PWR2.
5. M12 8- pin male
connector
for DI/DO
6. M12 8-pin female
connector for Ethernet
port
7. SFP Port
8. RS- . 232 console port
9. Reset button
10. Screw holes for wall
mounting
11. Waterproof vent
12. Grounding screw
13. rail Screw holes for -DIN
mounting
ATTENTION
Please DO NOT open or remove the vent 11
. The warranty will be
invalid if the seal is removed.
All exposed connectors, including 1, 2, 4 - 9, should be tightly
covered by suitable caps when they are not in use.
- - 5
Dimensions (unit = mm)
Attaching Antennas
The AWK directional antenna by - - -4131 inclues two dual band omni
default. Attach the antennas as illustrated below.
Step 1: -Use your fingers and hold the antenna metal N type connector.
Step 2: Screw the antenna N- -type connector (male) onto the AWK 4131
device’s N-type connector (female)
Caution
Do not hold the rubber plate to screw the antenna on to the
AWK- 4131 device.
ATTENTION
Use the antennas correctly: Use 2.4GHz antennas if the
AWK /n- 4131 operates in IEEE 802.11b/g . Use the 5GHz
antennas for operations in IEEE802.11a.
Make sure your antenna
instal
lation is within a safe area covered by a lightning protection
or surge arrest system.
Wall Mounting
In most applications, wall mount provides an easier installation. You will
find it quite easy to mount AWK- 4131 on the wall, as illustrated below.
Antenna Metal N- type
Rubber plate
- - 6
STEP 1:
Attach the wall-mounting kit
with M4 screws, as shown in
the diagram below.
STEP 2:
Mounting the AWK- 4131 on the wall
requires 4 screws. Use the AWK- 4131
device, with wall-mounting kit
attached, as a guide to mark the correct
locations of the 4 screws. The heads of
the screws are recommended to be
between 5.5mm and 8.5 mm in
diameter, and the shafts should not
be
more than 5.0 mm
in diameter, as
shown in the figure.
Do not screw the screws all the way in to the wall leave a space of about
2 mm to allow room for sliding the wall-mounting kit between the wall and
the screws.
ATTENTION
You can test the screw head and shank
size by inserting the screw
into one of the keyhole shaped apertures of the wall mounting
plates before it is screwed into the wall.
STEP 3:
Once the screws are fixed into the wall, insert the four screw heads
through the large opening of the shaped apertures, and then keyhole-
slide the AWK-4131 downwards, as indicated to the right. Tighten the
four screws for added stability.
ATTENTION
To avoid environmental vibration or shock, you can consider a
robust installation with four bigger screws, which the shafts are
between 7.0 mm and 8.5 mm in diameter, and fix the AWK-4131
onto wall directly and tightly.
- - 7
DIN- Rail Mounting (Optional)
The DK- -DC50131 die cast metal kit can be
bought separately, and enable easy and
robust installation for the AWK- . 4131
A pair
of DK- -DC50131s is needed for DIN Rail
mounting. To install the DIN-Rail mounting
kits, tightly attach the two DIN-Rail
mounting kits on the rear panel of AWK-4131
with 12 screws. (6 screws for each kit)
To Install
STEP 1:
Use the recessed button
on the spring-loaded
bracket to lock it into
position.
STEP 2:
Insert the top of the DIN-Rail into the slot
just below the upper hook of the DIN-Rail
mounting kit. Push the AWK- 4131 toward
the DIN-Rail until -the DIN Rail attachment
bracket snaps into place.
To Release
STEP 1:
Pull out the two spring-loaded
brackets from the bottom until
they are fixed in the “release”
position.
STEP 2:
Pull the AWK-4131 out and upward.
- - 8
Wiring Requirements
WARNING Safety First!
Be sure to disconnect the power cord before installing and/or
wiring your Moxa AWK- . 4131
Calculate the maximum possible current in each power wire and
common wire. Observe all electrical codes dictating the
maximum current allowable for each wire size. If the current goes
above the maximum ratings, the wiring could overheat, causing
serious damage to your equipment.
You should also pay attention to the following items:
Use separate paths to route wiring for power and devices. If power
wiring and device wiring paths must cross, make sure the wires are
perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring
in the same wire conduit. To avoid interference, wires with different
signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to
determine which wires should be kept separate. The rule of thumb is
that wiring with similar electrical characteristics can be bundled
together.
Keep input wiring and output wiring separate.
It is strongly advised that you label wiring to all devices in the system
when necessary.
Grounding Moxa AWK- 4131
Grounding and wire routing help limit the effects of noise due to
electromagnetic interference (EMI). Run the ground connection from the
ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded
mounting surface, such as a metal panel. There must be no
potential difference between two ground potentials, otherwise
there is a risk that the device could be destroyed.
Wiring the Redundant Power Inputs
The AWK over- -4131 must be connected to a power -Ethernet (PoE) IEEE
802.3af compliant power source or an IEC60950 compliant limited power
source. When AWK- 4131 is powered via DC power, the M12 A-coding
connector on the bottom panel is used for the AWK ’s two redundant -4131
inputs. The pin assignment is shown below:
Pin Power Input
1 V1+
2 V2+
3 - V1
4 - V2
5 GND
- - 9
ATTENTION
This product is intended to be supplied by a Listed Power Unit
marked “Class 2” or LPS” and rated O/P: 12 to 48 VDC, minimum
6 W (12 V/0.494 A to 48V/0.121 A, 25°C).
Make sure External Power Adaptor (includes power cords and
plug assemblies) provided with the unit is certified and suitable
for use in your country.
Before connecting the AWK-
4131 to the DC power inputs, make
sure the DC power source voltage is stable.
ATTENTION
Do not use the an PoE Injector. Instead, please use
IEEE802.3af
or IEEE802.3at compliant PSE (Power Sourcing Equipment) for
PoE (Power over Ethernet) . device
Wiring the Digital Inputs and Relay Contact
(Digital Output)
The AWK DI1 and DI2. Each DI - 4131 has two sets of digital input
comprises two contacts of the 8-pin M12 connector on the AWK-4131’s
bottom panel. These two digital inputs can be connected to
digital- - - output enabled sensors for on site status monitoring.
The AWK also has one relay output, which consists of the two - 4131
contacts. These relay contacts are used to detect user configured events. -
The two wires attached to the Relay contacts form an open circuit when a
user- -configured event is triggered. If a user configured event does not
occur, the Relay circuit will be closed.
A field installable plug, - M12A 8P- F- 7IP6 , is recommended for
connecting the AWK-4131’s DIs and relay.
Pin Signal
1 Relay
2
3 DI1 I1
4 DI1 COM_1
5 DI2 I2
6 DI2 COM_2
7 Reserved
8
- - 10
Communication Connections
Connecting the Data Lines
10/100/1000BaseT(X) Ethernet Port Connection
AWK- 4131 has 10/100/1000BaseT(X) Ethernet ports (8-pin shielded M12
connector with A coding). The 10/100/1000BaseT(X) ports located on the
AWK- 3 -41 1’s bottom panel are used to connect to Ethernet enabled
devices. Below we show pinouts for both MDI (NIC- -type) ports and MDI X
(HUB/Switch- type) ports.
Pinouts for the 10/100/1000BaseT(X) M12 (8- pin) Port
ATTENTION
To ensure the IP6 rated connectivity, you must use a 8-
waterproof housing during any communication activities. An
IP68- -rated field installable plug, which is attached in AWK 4131
’s
accessory pack, may be needed in this case. The installation
guide is shown below:
Ethernet M12 Plug
Dimensions (unit: mm)


Product specificaties

Merk: Moxa
Categorie: Wifi-repeater
Model: AWK-4131-M12-EU-T
Gewicht: 1800 g
Stroomvoorziening: 24 VDC
LED-indicatoren: Ja
Connectiviteitstechnologie: Draadloos
Frequentieband: 2.412 - 2.472, 5.18 - 5.24 GHz
Aansluiting voor netstroomadapter: Ja
Modulatie: 16-QAM, 64-QAM, BPSK, CCK, DBPSK, DQPSK, DSSS, OFDM, QPSK
Netwerkstandaard: IEEE 802.11a, IEEE 802.11b, IEEE 802.11g, IEEE 802.11n
Ondersteunde beveiligingsalgoritmen: WEP, WPA, WPA2
Temperatuur bij opslag: -40 - 85 °C
Power LED: Ja
MAC adres filtering: Ja
DHCP server: Ja
Veiligheid: UL 60950-1, EN 60950-1
Bedrijfstemperatuur, bereik: -40 - 167 °F
Aansluiting antenne: N-type
Mean time between failures (MTBF): 367406 uur
Maximale overdrachtssnelheid van gegevens: 300 Mbit/s
DHCP client: Ja
Power over Ethernet (PoE): Ja
Ondersteunde protocollen: Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP, RADIUS, SNMP, PPPoE, DHCP
Afmetingen (B x D x H): 224 x 147.7 x 64.5 mm
Full duplex: Ja
Bedrijfstemperatuur (T-T): -40 - 75 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 100 procent
Connectivity LEDs: Ja