Mitsubishi MSZ-EF25VE Handleiding

Mitsubishi Airco MSZ-EF25VE

Lees hieronder de 📖 handleiding in het Nederlandse voor Mitsubishi MSZ-EF25VE (32 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 63 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/32
CONTENTS
1. TECHNICAL CHANGES ··································· 3
2. PART NAMES AND FUNCTIONS ····················· 4
3. SPECIFICATION ················································ 5
4. NOISE CRITERIA CURVES ······························ 6
5. OUTLINES AND DIMENSIONS ························ 8
6. WIRING DIAGRAM ············································ 9
7. REFRIGERANT SYSTEM DIAGRAM ··············· 9
8. SERVICE FUNCTIONS ··································· 10
9. MICROPROCESSOR CONTROL ··················· 12
10. TROUBLESHOOTING ····································· 18
11. DISASSEMBLY INSTRUCTIONS ···················· 31
SPLIT-TYPE AIR CONDITIONERS
SERVICE MANUAL No. OBH589
REVISED EDITION-A
INDOOR UNIT
PARTS CATALOG (OBB589)
NOTE:
RoHS compliant products have <G> mark on the spec name plate.
Models
MSZ-EF22VEW -
E1
MSZ-EF25VEW -
E1
MSZ-EF35VEW -
E1
MSZ-EF42VEW -
E1
MSZ-EF50VEW -
E1
MSZ-EF22VEB -
E1
MSZ-EF25VEB -
E1
MSZ-EF35VEB -
E1
MSZ-EF42VEB -
E1
MSZ-EF50VEB -
E1
MSZ-EF22VES -
E1
MSZ-EF25VES -
E1
MSZ-EF35VES -
E1
MSZ-EF42VES -
E1
MSZ-EF50VES -
E1
Outdoor unit service manual
MUZ-EF·VE(H) Series (OBH590)
MXZ-C·VA Series (OB584)
Please void OBH589.
Revision A:
Airow in the Silent mode in the cooling
operation has been changed.
"
TROUBLESHOOTING" has been corrected.
2
<Preparation before the repair service>
Prepare the proper tools.
Prepare the proper protectors.
Provide adequate ventilation.
After stopping the operation of the air conditioner, turn o the power-supply breaker and remove the power plug.
Discharge the capacitor before the work involving the electric parts.
<Precautions during the repair service>
Do not perform the work involving the electric parts with wet hands.
Do not pour water into the electric parts.
Do not touch the refrigerant.
Do not touch the hot or cold areas in the refrigeration cycle.
When the repair or the inspection of the circuit needs to be done without turning o the power, exercise great caution not to
touch the live parts.
Use the speci ed refrigerant only
Never use any refrigerant other than that specied.
Doing so may cause a burst, an explosion, or re when the unit is being used, serviced, or disposed of.
Correct refrigerant is specied in the manuals and on the spec labels provided with our products.
We will not be held responsible for mechanical failure, system malfunction, unit breakdown or accidents caused by
failure to follow the instructions.
Revision A:
Airow in the Silent mode in the cooling operation has been changed.
"
TROUBLESHOOTING" has been corrected (10-2, 10-4).
3
TECHNICAL CHANGES
1
MSZ-EF22VEW - E1 MSZ-EF25VEW - E1 MSZ-EF35VEW - E1
MSZ-EF42VEW - E1 MSZ-EF50VEW - E1
MSZ-EF22VEB - E1 MSZ-EF25VEB - E1 MSZ-EF35VEB - E1
MSZ-EF42VEB - E1 MSZ-EF50VEB - E1
MSZ-EF22VES - E1 MSZ-EF25VES - E1 MSZ-EF35VES - E1
MSZ-EF42VES - E1 MSZ-EF50VES - E1
1. New model
These models are compatible with the outdoor units with low standby power control.
Connecting these models to the MUZ-EF·VE(H)-series outdoor units enables the low standby power control. Refer to the tech-
nical guide (OBT17) about the low standby power control.
These models may be connected to the MUZ-EF·VE(H) series after once connected to the MXZ series and operated, for
example because of relocation. In that case, the MUZ-EF·VE(H) series outdoor units will not operate without taking a step.
Follow the procedure "Deleting the memorized abnormal condition" described in 10-2.1.