Mitsubishi MSY-GL24NA-U1 Handleiding

Mitsubishi Airco MSY-GL24NA-U1

Lees hieronder de 📖 handleiding in het Nederlandse voor Mitsubishi MSY-GL24NA-U1 (4 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 76 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 1
The latest generation of wall-mounted M-Series models is here.
Introducing the GL line, the successor to the popular GE models.
These models provide enhanced, industry-leading performance for
the single-zone ductless product category.
FEATURES INCLUDE:
Washable long life lters
»Nano Platinum lter with deodorizing and anti-bacterial properties.
»Anti-allergy Enzyme lter traps dust and reduces germs, bacteria and viruses (except GL24).
Auto restart and auto cooling/heating changeover.
Air distribution
»Vertical air swing (all units).
»Horizontal swing (GL18, GL24 only).
»Wide airow (GL24 only).
Control functions
»Wireless hand-held controller.
»24-hour timer.
»Smart Set feature recalls the preset temperature by pressing single button on remote controller (GL06 – GL18 only).
»M-Net interface.
Multiple fan speeds: 5 speeds (GL06 – GL18), 4 speeds (GL24 only).
WHAT’S NEW:
All models ENERGY STAR qualied.
Quieter than previous GE models.
Blue Fin anti-corrosion coating on outdoor unit for increased coil protection and longer life.
New chassis for GL18 (35-5/16" x 12" x 9-3/16").
New logo treatment on indoor unit.
Compatible with kumo cloud™ control app and Thermostat Interface.
COMPATABILITY:
MSY/Z-GL and MUY/Z-GL models are not compatible with MSY/Z-GE and MUY/Z-GE models.
MSY/Z-GL and MSY/Z-GE indoor units are compatible with MXZ-C outdoor units.
PRODUCT GUIDE
MSZ-GL SINGLE-ZONE HEAT PUMP
M-SERIES SINGLE-ZONE
2 / MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS
SINGLE-ZONE
I
MSY System
Cooling Only
Model Name
Indoor Unit MSY-GL09NA-U1 MSY-GL12NA-U1 MSY-GL15NA-U1 MSY-GL18NA-U1 MSY-GL24NA-U1
Outdoor Unit MUY-GL09NA-U1 MUY-GL12NA-U1 MUY-GL15NA-U1 MUY-GL18NA-U1 MUY-GL24NA-U1
Cooling *1
Rated Capacity Btu/h 9,000 12,000 14,000 18,000 22,500
Capacity Range Btu/h 3,800 - 12,200 3,800 - 13,600 1,500 - 13,600 5,800-22,000 8,200-31,400
Rated Total Input W 585 920 1,080 1,340 1800
Energy Efciency SEER 24.6 23.1 21.6 20.5 20.5
Moisture Removal Pints/h 1.5 2.5 2.7 2.1 5.1
Sensible Heat Factor 0.820 0.740 0.800 0.870 0.750
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *2
Voltage
Indoor - Outdoor S1 - S2 AC 208 / 230V
Indoor - Outdoor S2 - S3 DC ±24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC 12V)
Indoor Unit
MCA A 1.0
Blower Motor (ECM) F.L.A. 0.760.76 0.67
Airow at Cooling
(Quiet-Lo-Med-Hi-Super Hi)*1
DRY (CFM) 205-272-335-420-533 388-469-544-628-738145-170-237-321-399 258-332-417-522-646
WET (CFM) 170-237-300-385-498 347-420-487-562-661109-134-201-286-364 232-299-375-470-581
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi)*1 dB(A) 19-22-30-37-43 19-22-30-37-45 26-32-38-44-49 28-33-38-44-49 34-41-45-49-53
External Finish Color Munsell 1.0Y 9.2 / 0.2
Dimension Unit
W: In. 31-7/16 36-5/16 43-5/16
D: In. 9-1/8 9-13/16 9-3/8
H: In. 11-5/8 12 12-13/16
Weight Unit Lbs. 22 28 37
Field Drainpipe Size O.D. In. 5/8
Remote
Controller Type Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
Outdoor Unit
MCA A 7 9 14 17.1
MOCP A 15 20
Fan Motor (ECM) F.L.A. 0.50 0.93
Compressor
Model
(Type) DC INVERTER-driven DC INVERTER-driven Twin Rotary
R.L.A. 4.9 6.8 10.0 12.9
L.R.A. 6.1 8.5 12.5 16.1
Airow (Cooling) CFM 1,229/1,172 1,243/1,229 1,691/1,691 1,769/1,701
Refrigerant Control Linear Expansion Valve
Sound Pressure Level at Cooling *1 dB(A) 48 49 54 55
External Finish Color Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In. 31-1/2 33-1/16
D: In. 11-1/4 13
H: In. 21-5/8 34-5/8
Weight Lbs. 81 121 119
Refrigerant
Type R410A
Charge Lbs., Oz. 2, 9 3, 7 4, 3
Oil Type (fl. oz.) FV50S (0.27) FV50S (0.35) FV50S (0.40)
Refrigerant
Pipe
Gas Side O.D. In. 3/8 1/2 5/8
Liquid Side O.D. In. 1/4 3/8
Refrigerant Pipe
Length
Height Difference (Max.) Ft.. 40 50
Length (Max.) Ft.. 65 100
Connection
Method Indoor/Outdoor Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) - Indoor D.B. 80º F (27º C), W.B. 67º F (19º C); Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specications are subject to change without notice.
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.
MITSUBISHI ELECTRIC / M-SERIES / SPECIFICATIONS / 3
Model Name
Indoor Unit MSZ-GL09NA-U1 MSZ-GL12NA-U1 MSZ-GL15NA-U1 MSZ-GL18NA-U1 MSZ-GL24NA-U1
Outdoor Unit MUZ-GL09NA-U8 MUZ-GL12NA-U1 MUZ-GL15NA-U1 MUZ-GL18NA-U1 MUZ-GL24NA-U1
Cooling *1
Rated Capacity Btu/h 9,000 12,000 14,000 18,000 22,400
Capacity Range Btu/h 3,600 - 12,200 1,500 - 13,600 3,100 - 18,200 5,800 - 22,000 8,200 - 31,400
Rated Total Input W 585 920 1,080 1,340 1,800
Energy Efciency SEER 24.6 23.1 21.6 20.5 20.5
Moisture Removal Pints/h 1.5 2.5 2.7 2.1 5.1
Sensible Heat Factor 0.820 0.740 0.800 0.870 0.750
Heating at 47°
F *2
Rated Capacity Btu/h 10,900 14,400 18,000 21,600 27,600
Capacity Range Btu/h 4,500 - 14,100 5,500 - 18,100 4,800 - 20,900 5,400 - 25,000 7,500 - 36,900
Rated Total Input W 720 1,100 1,600 1,680 2,340
HSPF (IV) Btu/h/W 12.8 12.5 11.7 11.2 10.0
Heating at 17°
F *3
Rated Capacity Btu/h 7,000 12,000 16,400 18,200 24,600
Rated Total Input W 620 9,200 12,200 13,800 16,000
Maximum Capacity Btu/h 9,400 1,240 1,850 2,150 3,290
Heating at 5° F Maximum Capacity Btu/h 7,600 9,700 13,700 14,500 21,160
Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *4
Voltage
Indoor - Outdoor S1 - S2 AC 208 / 230V
Indoor - Outdoor S2 - S3 DC ±24V
Indoor - Remote Controller Wireless Type (Optional Wired Controller: DC12V)
Indoor Unit
MCA A 1.0
Blower Motor (ECM) F.L.A. 0.76 0.760.67
Airow at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1
DRY (CFM) 145-170-237-321-399 205-272-335-420-533 388-469-544-628-738259-333-416-523-646
WET (CFM) 109-134-201-286-364 170-237-300-385-498 347-420-487-562-661233-300-375-470-581
Airow at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2 DRY (CFM) 145-170-237-321-406 205-247-304-367-463 296-384-469-563-646 388-469-544-628-738
External Static Pressure In. WG
Sound Pressure Level at Cooling
(Quiet-Lo-Med-Hi-Super Hi) *1 dB(A) 19-22-30-37-43 19-22-30-37-45 26-32-38-44-49 28-33-38-44-49 34-41-45-49-53
Sound Pressure Level at Heating
(Quiet-Lo-Med-Hi-Super Hi) *2 dB(A) 19-22-30-37-43 19-22-30-37-43 26-30-35-40-46 28-33-38-43-48 32-41-45-49-52
External Finish Color Munsell 1.0Y 9.2 / 0.2
Dimension Unit
W: In. 31-7/16 36-5/16 43-5/16
D: In. 9-1/8 9-13/16 9-3/8
H: In. 11-5/8 12 12-13/16
Weight Unit Lbs. 22 28 37
Field Drainpipe Size O.D. In. 5/8
Remote
Controller Type Select from PAC-WHS01WF-E for kumo cloud™, PAC-US444CN-1, MHK1, PAR-31MAA, or PAC-YT53CRAU Remote Controllers
Outdoor Unit
MCA A 9 10 14 17.1
MOCP A 15 20
Fan Motor (ECM) F.L.A. 0.5 0.93
Compressor
Model
(Type) DC INVERTER-driven Twin Rotary
R.L.A. 6.2 6.6 7.4 10.0 12.9
L.R.A. 7.7 8.2 9.3 12.5 16.1
Airow (Cooling/Heating) CFM 1,229/1,172 1,229 / 1,172 1,243 / 1,229 1,691 / 1,691 1,769 / 1,701
Refrigerant Control Linear Expansion Valve
Defrost Method Reverse Cycle
Sound Pressure Level at Cooling *1 dB(A) 48 49 54 55
Sound Pressure Level at Heating *2 dB(A) 50 51 55
External Finish Color Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In. 31-1/2 33-1/16
D: In. 11-1/4 13
H: In. 21-5/8 34-5/8
Weight Lbs. 81 121 119
Refrigerant
Type R410A
Charge Lbs., Oz. 2, 9 3, 7 4, 3
Oil Type (fl. oz.) FV50S (0.35) FV50S (0.40)
Refrigerant Pipe Gas Side O.D. In. 3/8 1/2 5/8
Liquid Side O.D. In. 1/4 3/8
Refrigerant Pipe
Length
Height Difference (Max.) Ft. 40 50
Length (Max.) Ft. 65 100
Connection
Method Indoor/Outdoor Flared/Flared
SINGLE-ZONE
I
MSZ System
I
Heat Pump
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling)-Indoor: D.B. 80º F (27º C), W.B. 67º F (19º C);
Outdoor: D.B. 95º F (35º C), W.B. 75º F (24º C).
*2. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 47º F (8º C), W.B. 43º F (6º C).
*3. Rating conditions (heating)-Indoor: D.B. 70º F (21º C), W.B. 60º F (16º C);
Outdoor: D.B. 17º F (-8º C), W.B. 15º F (-9º C).
*4. Indoor units receive power from outdoor units through field-supplied interconnected wiring.
Specications are subject to change without notice.
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.


Product specificaties

Merk: Mitsubishi
Categorie: Airco
Model: MSY-GL24NA-U1

Heb je hulp nodig?

Als je hulp nodig hebt met Mitsubishi MSY-GL24NA-U1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Mitsubishi

Handleiding Airco

Nieuwste handleidingen voor Airco