Mitsubishi MSH-GA60VB Handleiding
Mitsubishi
Airco
MSH-GA60VB
Lees hieronder de 📖 handleiding in het Nederlandse voor Mitsubishi MSH-GA60VB (14 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 109 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld
Pagina 1/14
SPLIT-TYPE AIR CONDITIONERS
OPERATING INSTRUCTIONS
INDOOR UNIT
MS-GA50VB
MS-GA60VB
MS-GA80VB
MSH-GA50VB
MSH-GA60VB
MSH-GA71VB
MSH-GA80VB
For customers
Thank you very much for purchasing this Mitsubishi room air conditioner.
•
To use this unit correctly and safely, be sure to read this operating instructions
before use. Keep this manual carefully for later reference.
•
Be sure to receive a guarantee card from your dealer and check that the
purchased date
and shop name, etc. are entered correctly.
• This air conditioner should not be installed by the customer.
(Safety and performance functions cannot be assured.)
2
AIR OUTLET
• This air conditioner is NOT intended for use by children or infirm persons without supervisions.
Do not use intermediate connection of the power supply cord or the extension cord and do not
connect many devices to one AC outlet.
•
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Remove dirt from the power supply plug and securely insert the plug into the outlet.
• If dirt adheres to the plug or insertion is incomplete, it may cause a fire or an electric shock.
Do not scratch or process the power supply cord, etc.
• Do not put heavy object on the power supply cord and do not scratch or process the cord. The cord may
be damaged and this may cause a fire or an electric shock.
Do not turn the breaker off/on and/or disconnect/connect the power supply plug during operation.
• This may cause a fire due to spark, etc.
• Be sure to turn off the breaker and/or disconnect the power supply plug absolutely after switching the
indoor unit off with the remote controller.
Do not expose your skin directly to cool air for a long time.
• This could damage your health.
Installation, repairs or relocation should not be done by the customer.
• If this is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc. Consult your dealer.
• If the power supply cord is damaged, it must be replaced by the manufacturer or its service agent in order
to avoid a hazard.
Do not insert your finger or a stick, etc. into the air inlet/outlet.
• Since the fan rotates at high speed, this may cause an injury.
• Young children should be supervised to ensure that they do not play with the air conditioner.
When an abnormality (burning smell, etc.) occurs, stop the air conditioner and disconnect the power
supply plug and/or turn off the breaker.
• If the unit continues to be operated in an abnormal condition, it may cause a fire, trouble, etc. In this case,
consult your dealer.
WARNING
CONTENTS
SAFETY PRECAUTIONS ............................................................................................................................................................2
NAME OF EACH PART ...............................................................................................................................................................3
PREPARATION BEFORE OPERATION .....................................................................................................................................4
I FEEL... AUTO OPERATION ......................................................................................................................................................6
MANUAL OPERATION (COOL, DRY, HEAT/FAN) ......................................................................................................................7
AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT ..........................................................................................................7
LONG OPERATION ....................................................................................................................................................................8
ECONO COOL OPERATION ......................................................................................................................................................8
TIMER OPERATION (ON/OFF TIMER) ......................................................................................................................................8
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME ...............................................................9
MAINTENANCE ..........................................................................................................................................................................9
CLEANING THE AIR FILTER (CATECHIN) ..............................................................................................................................10
REPLACEMENT OF THE AIR CLEANING FILTER .................................................................................................................10
BEFORE CONTACTING THE SERVICE REPRESENTATIVE, CHECK THE FOLLOWING AGAIN ........................................11
WHEN YOU THINK THAT TROUBLE HAS OCCURRED .........................................................................................................11
INSTALLATION, RELOCATION AND INSPECTION .................................................................................................................12
SAFETY PRECAUTIONS
• Since rotating parts and parts which could cause an electric shock are used in this product, be sure to read these
“Safety Precautions” before use.
• Since the cautionary items shown here are important for safety, be sure to observe them.
• Stop using the air conditioner and consult your dealer in case any trouble or abnormality occurs.
Marks and their meanings
WARNING: Incorrect handling could cause a serious hazard, such as death, serious injury, etc. with a high
probability.
CAUTION: Incorrect handling could cause a serious hazard depending on the conditions.
Meanings of symbols used in this manual
: Be sure not to do.
: Be sure to follow the instruction.
: Never insert your finger or stick, etc.
: Never step onto the indoor/outdoor unit and do not put anything on them.
: Danger of electric shock. Be careful.
: Be sure to disconnect the power supply plug from the power outlet.
: Be sure to shut off the power.
• After reading this manual, keep it together with the installation manual in a handy place for easy reference.
Warning positions
FRONT PANEL
ENCLOSURE
When the air filter is to be removed, do not touch the metal part of the indoor unit.
• This may cause an injury.
Do not touch the air inlet or aluminum fin of the outdoor unit.
• This may cause an injury.
Do not put a vase or glass on the indoor unit.
• Water dropping into the indoor unit may deteriorate the insulation, causing electric shock.
Do not use an insecticide or flammable spray.
• This may cause a fire or deformation of the cabinet.
Do not put a pet or houseplant where it will be exposed to direct airflow.
• This could injure the pet or plant.
Do not place other electric appliances or furniture under the indoor/outdoor unit.
• Water may drip down from the unit, and this may cause damage or malfunction to them.
Do not leave the unit on an installation stand which is damaged.
• The unit may fall and this may cause an injury.
Do not step onto an unstable bench when maintaining the unit, etc.
• This may cause an injury, etc. if you fall down.
Do not pull the power supply cord.
• The core wire of the power supply cord may be disconnected and this may cause a fire.
Do not charge or disassemble the batteries and do not throw them into a fire.
• This may result in leakage, fire or an explosion.
Do not operate the unit for a long time in high humidity, e.g. leaving a door or window open.
• In the cooling mode, if the unit is operated in a room with high humidity (80% RH or more) for a long time,
water condensed in the air conditioner may drop and wet or damage furniture, etc.
CAUTION
ENCLOSURE
3
MU-GA60VB
MUH-GA60VB
MUH-GA71VB
MU-GA80VB
MUH-GA80VB
MU-GA50VB
MUH-GA50VB
Operation Indicator
SAFETY PRECAUTIONS
For installation
Do not use the unit for special purposes.
• Do not use this air conditioner to preserve precision devices, food, animals, plants and art objects.
This may cause deterioration of quality, etc.
Do not put a stove, etc. where they are exposed to direct airflow.
• This may cause imperfect combustion.
When the unit is to be cleaned, switch it off and disconnect the power supply plug and/or turn off
the breaker.
• Since the fan rotates at high speed during operation, this may cause an injury.
When the unit is not going to be used for a long time, disconnect the power supply plug and/or turn
off the breaker.
• Otherwise, dirt may collect and this may cause a fire.
Replace the 2 batteries of the remote controller with new ones of same type.
• Using an old battery together with a new one may result in heat generation, leakage or an explosion.
If liquid from the batteries gets onto your skin or clothes, wash it well with clean water.
•
If liquid from the batteries gets into your eyes, wash them well with clean water and consult a doctor at once.
Ventilate well in using the unit with a stove, etc.
• An oxygen shortage may occur.
Do not operate switches with wet hands.
• This may cause an electric shock.
Do not clean the air conditioner with water or put a vase or glass on it.
• Water may enter the unit and degrade the insulation. This may cause an electric shock.
Do not step or put anything on the indoor/outdoor unit.
• This may cause an injury, etc. if you or something falls down.
CAUTION
Earth the unit.
• Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing
is incorrect, it may cause an electric shock.
Install an earth leakage breaker depending on the place where the air conditioner is to be installed
(humid places, etc.).
• If the earth leakage breaker is not installed, it may cause an electric shock.
Drain should be fully drained.
•
If the drainage route is incomplete, water may drop from the unit. This may wet and damage the furniture.
CAUTION
WARNING
• Consult your dealer or contractor for installation of the air conditioner. Since special techniques and work are
required, installation should not be done by the customer. If this is done incorrecty, it may cause a fire, an electric
shock, injury or water leaking.
• Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause an explosion.
NAME OF EACH PART
Indoor unit
Outdoor unit
Emergency operation switch
Remote control
receiving section
Piping
Air outlet
Drain outlet
Air cleaning filter
(White bellows type)
Vertical vane
Operation section
(When the front panel is opened)
Display section
Horizontal vane
Air inlet (back and side)
Drainage hose
Operation Indicator lamp
Air filter (Catechin)
Front panel
Air inlet
Power supply cord
Remote control
receiving section
Remote controller
Power supply plug
Product specificaties
Merk: | Mitsubishi |
Categorie: | Airco |
Model: | MSH-GA60VB |
Kleur van het product: | Wit |
Soort: | Binneneenheid airconditioning |
Stroom: | 15.5 A |
Koelend medium: | R410A |
Multi-split: | Nee |
Air conditioner functies: | Cooling,Heating |
Jaarlijks energieverbruik (koelen): | - kWu |
Jaarlijks energieverbruik (verwarming) (warmer stookseizoen): | - kWu |
Jaarlijks energieverbruik (verwarming) (gemiddelde stookseizoen): | - kWu |
Extern geluidsniveau: | - dB |
Intern geluidsniveau (hoge snelheid): | 47 dB |
Koelcapaciteit in watt (opgegeven): | 6300 W |
Verwarmingscapaciteit in watt (opgegeven) (warmer stookseizoen): | - W |
Verwarmingscapaciteit in watt (opgegeven) (gemiddelde stookseizoen): | - W |
Verwarmingscapaciteit in watt (opgegeven) (kouder stookseizoen): | - W |
Energieverbruik per uur (koeling): | - kWu |
Energieverbruik per uur (verwarming): | - kWu |
Breedte binnenunit: | 1100 mm |
Diepte binnenunit: | 258 mm |
Hoogte binnenunit: | 325 mm |
Ontvochtiging capaciteit: | 2.2 L/u |
Koeling energie efficientie: | 2.81 |
Verwarming energie efficientie: | 3.26 |
Indoor unit type: | Muur-montage |
Indoor eenheid gewicht: | 16000 g |
Jaarlijks energieverbruik (verwarming) (kouder stookseizoen): | - kWu |
Ontwerpbelasting (koeling): | - kW |
Ontwerpbelasting (verwarming) (warmer stookseizoen): | - kW |
Ontwerpbelasting (verwarming) (gemiddelde stookseizoen): | - kW |
Ontwerpbelasting (verwarming) (kouder verwarmingsseizoen): | - kW |
Indoor units hoeveelheid: | 1 |
Wifi: | Nee |
AC-ingangsspanning: | 230 V |
AC-ingangsfrequentie: | 50 Hz |
Heb je hulp nodig?
Als je hulp nodig hebt met Mitsubishi MSH-GA60VB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Mitsubishi
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
14 December 2024
Handleiding Airco
- Airco Electrolux
- Airco Bosch
- Airco Candy
- Airco Samsung
- Airco Delonghi
- Airco Panasonic
- Airco LG
- Airco AEG
- Airco Bauknecht
- Airco BEKO
- Airco Daewoo
- Airco Grundig
- Airco Honeywell
- Airco Inventum
- Airco Karcher
- Airco Medion
- Airco Remeha
- Airco Siemens
- Airco Toshiba
- Airco Unold
- Airco Vaillant
- Airco Whirlpool
- Airco Zanussi
- Airco Zibro
- Airco Adler
- Airco Airwell
- Airco Akai
- Airco Amana
- Airco Amcor
- Airco Apc
- Airco Arcelik
- Airco Argo
- Airco Balay
- Airco Bartscher
- Airco Bavaria
- Airco Be Cool
- Airco Bestron
- Airco Blaupunkt
- Airco Blumfeldt
- Airco Bodin
- Airco Bomann
- Airco Brandt
- Airco D-Let
- Airco Daikin
- Airco Daitsu
- Airco Defy
- Airco Dimplex
- Airco Dometic
- Airco Domo
- Airco Duracraft
- Airco Duux
- Airco Easy Home
- Airco Eco-De
- Airco Eden
- Airco Edgestar
- Airco Edy
- Airco Einhell
- Airco Emerio
- Airco Emerson
- Airco Eurom
- Airco Everglades
- Airco Evolar
- Airco Exquisit
- Airco Fairland
- Airco Ferroli
- Airco Finlux
- Airco Firstline
- Airco Fral
- Airco Frigidaire
- Airco Frilec
- Airco Fronius
- Airco Fuave
- Airco Fuji Electric
- Airco Fujitsu
- Airco G3 Ferrari
- Airco GE
- Airco General Electric
- Airco GlobalTronics
- Airco Gorenje
- Airco Gree
- Airco Gutfels
- Airco H.Koenig
- Airco Haier
- Airco Hisense
- Airco Hitachi
- Airco Holland Electro
- Airco Home Electric
- Airco Hotpoint
- Airco Hotpoint-Ariston
- Airco HQ
- Airco Hyundai
- Airco Iceberg
- Airco Innoliving
- Airco Insignia
- Airco Itho
- Airco Kalorik
- Airco Kelvinator
- Airco Kenmore
- Airco Klarstein
- Airco Koenic
- Airco Kogan
- Airco Korona
- Airco Lanaform
- Airco Lavorwash
- Airco Livington
- Airco Livoo
- Airco Logik
- Airco Maiko
- Airco Manta
- Airco Master
- Airco Maxicool
- Airco Meaco
- Airco Meireles
- Airco Melissa
- Airco Mesko
- Airco Mestic
- Airco Midea
- Airco Mistral
- Airco Moa
- Airco MPM
- Airco MundoClima
- Airco Nabo
- Airco Nedis
- Airco Philco
- Airco Prem-i-air
- Airco Primo
- Airco Princess
- Airco Profile
- Airco Progress
- Airco Proklima
- Airco Proline
- Airco Protector
- Airco Qlima
- Airco RCA
- Airco REMKO
- Airco Rotel
- Airco Rowenta
- Airco Royal Sovereign
- Airco Russell Hobbs
- Airco Sanyo
- Airco Sauber
- Airco Saunier Duval
- Airco Sencor
- Airco Sencys
- Airco Sharp
- Airco Sigma
- Airco SMC
- Airco Sonnenkonig
- Airco SPT
- Airco Starlyf
- Airco Stirling
- Airco Suntec
- Airco Tarrington House
- Airco Taurus
- Airco TCL
- Airco Team
- Airco Technisat
- Airco Teco
- Airco Tectro
- Airco Telefunken
- Airco Termozeta
- Airco Theben
- Airco Thomson
- Airco Tomado
- Airco Tosot
- Airco Toyotomi
- Airco Trilec
- Airco Tristar
- Airco Tronix
- Airco Trotec
- Airco Truma
- Airco Ufesa
- Airco Vestel
- Airco Vivax
- Airco Waeco
- Airco Westinghouse
- Airco White Knight
- Airco Whynter
- Airco Woods
- Airco Zelmer
- Airco Jocca
- Airco Jocel
- Airco Just Fire
- Airco OK
- Airco Olimpia Splendid
- Airco OneConcept
- Airco Oregon Scientific
- Airco Ozito
- Airco Becken
- Airco Black And Decker
- Airco Camry
- Airco Clatronic
- Airco Concept
- Airco ECG
- Airco Elba
- Airco Essentiel B
- Airco Guzzanti
- Airco Heinner
- Airco Khind
- Airco Orbegozo
- Airco Profilo
- Airco Trisa
- Airco Vox
- Airco Wilfa
- Airco Anslut
- Airco Kunft
- Airco Soler And Palau
- Airco Conrad
- Airco Ansonic
- Airco Aspes
- Airco Comfee
- Airco Corberó
- Airco Danby
- Airco Equator
- Airco Esatto
- Airco IFB
- Airco Infiniton
- Airco Koldfront
- Airco Listo
- Airco Orima
- Airco Svan
- Airco Ardes
- Airco Eldom
- Airco Premium
- Airco Teesa
- Airco Alpatec
- Airco ElectriQ
- Airco Heylo
- Airco HTW
- Airco Prime3
- Airco Avidsen
- Airco SereneLife
- Airco DCG
- Airco Kubo
- Airco Malmbergs
- Airco Challenge
- Airco Calor
- Airco Riffel
- Airco Broan
- Airco RIDGID
- Airco KDK
- Airco Bimar
- Airco Climadiff
- Airco Tripp Lite
- Airco Mabe
- Airco Equation
- Airco Godrej
- Airco Milectric
- Airco Orava
- Airco Simplicity
- Airco Cecotec
- Airco Baxi
- Airco Thermex
- Airco Keystone
- Airco Sanus
- Airco Carrier
- Airco Furrion
- Airco Rinnai
- Airco Carson
- Airco Artrom
- Airco Carrefour Home
- Airco Céliera
- Airco Commercial Cool
- Airco Coolix
- Airco Hokkaido
- Airco Kibernetik
- Airco Norpole
- Airco Senville
- Airco SHE
- Airco CyberPower
- Airco Perfect Aire
- Airco Be Quiet!
- Airco Ariston Thermo
- Airco Element
- Airco Dantherm
- Airco Argoclima
- Airco DEXP
- Airco Chigo
- Airco Elgin
- Airco Evapolar
- Airco EcoFlow
- Airco Liebert
- Airco Avalon Bay
- Airco NewAir
- Airco Braemar
- Airco ActronAir
- Airco Klimaire
- Airco Consul
- Airco SEEGER
- Airco LERAN
- Airco Friedrich
- Airco Aerian
- Airco Polocool
- Airco Convair
- Airco Companion
- Airco Volteno
- Airco Arcoaire
- Airco AFINTEK
- Airco Brivis
- Airco MRCOOL
- Airco B-Air
- Airco Monzana
- Airco Kaden
- Airco Geist
- Airco GoldAir
- Airco Avallon
- Airco Ravanson
- Airco Create
- Airco Columbia Vac
- Airco TURBRO
- Airco House & Luft
- Airco Daizuki
- Airco Bonaire
- Airco Evapcool
- Airco Vostok
- Airco American Comfort
- Airco Ocean Breeze
- Airco Quirky
- Airco Krone
- Airco KwiKool
- Airco Big Ass Fans
- Airco Arctic King
- Airco Omega Altise
- Airco Climachill
- Airco Heat Controller
- Airco Luma Comfort
- Airco AireMax
- Airco Kaco
- Airco Middle Atlantic
- Airco Goodwe
- Airco Swegon
- Airco InAlto
- Airco JHS
- Airco FREONIC
- Airco ARCTIC WIND
- Airco Electroline
- Airco BLUEPALM
- Airco KuulAire
- Airco Cool-Space
- Airco BOSFOR
- Airco Aconatic
- Airco VänEE
- Airco Mayer
- Airco Yamazen
- Airco Corona
- Airco Symphony
- Airco Soler & Palau
- Airco Universal Blue
Nieuwste handleidingen voor Airco
22 December 2024
22 December 2024
21 December 2024
20 December 2024
18 December 2024
18 December 2024
18 December 2024
14 December 2024
14 December 2024
14 December 2024