SECTION 1: Identification of the substance/mixture and of the company/undertaking
1.1. Product identifier
Product form : Mixture
Product name : MAKITA CHAINSAW OIL
Product code : 10070
1.2. Relevant identified uses of the substance or mixture and uses advised against
THIS PRODUCT MUST NOT BE USED IN APPLICATIONS OTHER THAN THOSE RECOMMENDED IN SECTION 1.2.1, WITHOUT FIRST
SEEKING THE ADVICE OF THE SUPPLIER.
1.2.1. Relevant identified uses
Intended for general public
Main use category : Consumer use
1.2.2. Uses advised against
No additional information available
1.3. Details of the supplier of the safety data sheet
Rock Oil
90 Priestley Street
WA5 1ST Warrington - UK
T +44 1925 636191
mail@rockoil.co.uk
1.4. Emergency telephone number
Emergency number : +44 1925 636191
SECTION 2: Hazards identification
2.1. Classification of the substance or mixture
Classification according to Regulation (EC) No. 1272/2008 [CLP]
Not classified
Classification according to Directive 67/548/EEC or 1999/45/EC
Not classified
Adverse physicochemical, human health and environmental effects
Not expected to present a significant hazard under anticipated conditions of normal use.
2.2. Label elements
Labelling according to Directive 67/548/EEC or 1999/45/EC
No labelling applicable
2.3. Other hazards
Other hazards not contributing to the
classification : None under normal conditions.
SECTION 3: Composition/information on ingredients
3.1. Substance
Not applicable
3.2. Mixture
This mixture does not contain any substances to be mentioned according to the criteria of section 3.2 of REACH annex II
MAKITA CHAINSAW OIL
Safety Data Sheet
according to Regulation (EC) No. 453/2010
28/11/2013 EN (English) 2/5
SECTION 4: First aid measures
4.1. Description of first aid measures
First-aid measures general : Never give anything by mouth to an unconscious person. If you feel unwell, seek medical
advice (show the label where possible).
First-aid measures after inhalation : Assure fresh air breathing. Allow the victim to rest.
First-aid measures after skin contact : Remove affected clothing and wash all exposed skin area with mild soap and water, followed
by warm water rinse.
First-aid measures after eye contact : Rinse immediately with plenty of water. Obtain medical attention if pain, blinking or redness
persist.
First-aid measures after ingestion : Rinse mouth. Do NOT induce vomiting. Obtain emergency medical attention.
4.2. Most important symptoms and effects, both acute and delayed
Symptoms/injuries : Not expected to present a significant hazard under anticipated conditions of normal use.
4.3. Indication of any immediate medical attention and special treatment needed
Treat symptomatically.
SECTION 5: Firefighting measures
5.1. Extinguishing media
Suitable extinguishing media : Foam. Dry powder. Carbon dioxide. Water spray. Sand.
Unsuitable extinguishing media : Do not use a heavy water stream.
5.2. Special hazards arising from the substance or mixture
Reactivity : No reactivity hazard other than the effects described in sub-sections below.
5.3. Advice for firefighters
Firefighting instructions : Use water spray or fog for cooling exposed containers. Exercise caution when fighting any
chemical fire. Prevent fire-fighting water from entering environment.
Protection during firefighting : Do not enter fire area without proper protective equipment, including respiratory protection.
SECTION 6: Accidental release measures
6.1. Personal precautions, protective equipment and emergency procedures
6.1.1. For non-emergency personnel
Protective equipment : Avoid contact with skin and eyes.
Emergency procedures : Evacuate unnecessary personnel.
6.1.2. For emergency responders
Protective equipment : Equip cleanup crew with proper protection.
Emergency procedures : Ventilate area.
6.2. Environmental precautions
Prevent entry to sewers and public waters. Notify authorities if liquid enters sewers or public waters.
6.3. Methods and material for containment and cleaning up
Methods for cleaning up : Soak up spills with inert solids, such as clay or diatomaceous earth as soon as possible. Collect
spillage. Store aways from other materials.
6.4. Reference to other sections
See also sections 8 and 13.
SECTION 7: Handling and storage
7.1. Precautions for safe handling
Precautions for safe handling : Wash hands and other exposed areas with mild soap and water before eating, drinking or
smoking and when leaving work. Provide good ventilation in process area to prevent formation
of vapour.
7.2. Conditions for safe storage, including any incompatibilities
Storage conditions : Keep container closed when not in use. Store in original container. Protect from moisture. Keep
cool.
Incompatible products : Oxidizing agent. Strong acids. Strong bases.
Incompatible materials : Sources of ignition. Direct sunlight.
Storage temperature : 0 - 40 °C
7.3. Specific end use(s)
Lubricant oil.
MAKITA CHAINSAW OIL
Safety Data Sheet
according to Regulation (EC) No. 453/2010
28/11/2013 EN (English) 3/5
SECTION 8: Exposure controls/personal protection
8.1. Control parameters
MAKITA CHAINSAW OIL
ACGIH TWA (mg/m³) 5 mg/m³ Refined mineral oil, mist
8.2. Exposure controls
Appropriate engineering controls : Ensure exposure is below occupational exposure limits (where available).
Personal protective equipment : Avoid all unnecessary exposure.
Hand protection : In case of repeated or prolonged contact wear gloves. Standard EN 374 - Protective gloves
against chemicals. Wear protective gloves.
Eye protection : If there is a risk of liquid being splashed : Standard EN 166 - Personal eye-protection. Chemical
goggles or safety glasses.
Skin and body protection : Wear suitable protective clothing.
Respiratory protection : In case of insufficient ventilation, wear suitable respiratory equipment. Wear appropriate mask.
Thermal hazard protection : Not specifically applicable.
Environmental exposure controls : SECTION 6.
Other information : Do not eat, drink or smoke during use.
SECTION 9: Physical and chemical properties
9.1. Information on basic physical and chemical properties
Physical state : Liquid
Appearance : Mobile liquid.
Colour : amber.
Odour : characteristic.
Odour threshold : No data available
pH : Not classified
Relative evaporation rate (butylacetate=1) : No data available
Melting point : No data available
Freezing point : No data available
Boiling point : > 280 °C IBP
Flash point : > 210 °C PMCC
Self ignition temperature : > 320 °C
Decomposition temperature : No data available
Flammability (solid, gas) : Non flammable
Vapour pressure : < 0.5 kPa @ 20°C
Relative vapour density at 20 °C : No data available
Relative density : 0.893 kg/l @ 15°C
Solubility : Insoluble in water. Soluble in aliphatic hydrocarbons.
Log Pow : No data available
Log Kow : No data available
Viscosity, kinematic : 150 cSt @40°C
Viscosity, dynamic : No data available
Explosive properties : Not classified.
Oxidising properties : Not classified.
Explosive limits : No data available
9.2. Other information
VOC content : 0 %
SECTION 10: Stability and reactivity
10.1. Reactivity
No reactivity hazard other than the effects described in sub-sections below.
10.2. Chemical stability
Stable under recommended handling and storage conditions (see section 7).
10.3. Possibility of hazardous reactions
May react violently with oxidants.
10.4. Conditions to avoid
Direct sunlight. Extremely high or low temperatures.


Product specificaties

Merk: Makita
Categorie: Niet gecategoriseerd
Model: P-21163

Heb je hulp nodig?

Als je hulp nodig hebt met Makita P-21163 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Makita

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd