LG PBM13M1UA0 Handleiding

LG Airco PBM13M1UA0

Lees hieronder de 📖 handleiding in het Nederlandse voor LG PBM13M1UA0 (4 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
* UV model name : LTPL-G35U275GS-TWA
M Series Duct UVnano Filter
Box Installation/User Guide
* UVnano is a compound word derived from the words UV and its unit nanometer.
Be sure to read the safety precautions before using the product. These precautions are
intended to protect the user while preventing property loss. After reading the
installation/user guide, keep it in a location where user can access it anytime.
WARNING
Not following the instructions could result in death or severe injury to the user.
CAUTION
Not following the instructions could result in injury to the user or property damage.
!
!
Things to Remember
• Since the installation requires specialized skills, the product must be installed by a service centre
or an installation centre approved by LG electronics. (If installation is carried out by a person
without an installation license, that person is responsible for all problems related to the
installation, in which case LG Electronics shall provide no free maintenance or repair service.)
• After the installation is completed, be sure to show the customer that the product functions
normally and has no problems.
• Before installation, be sure to read the Installation/User guide.
WARNING
!
• This appliance can be used by children aged from 8 years and above and
persons with reduced physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given supervision or instruction
concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.
• The appliance shall be disconnected from its power source during service and when replacing
parts.
• This appliance contains a UV-C lamp, do not stare at the light source.
• Read the maintenance instructions before opening the appliance.
• Unintended usage of the appliance or damage to the housing may result in the escape of
dangerous UV-C radiation. UV-C radiation may, even in small doses, cause harm to the eyes and
skin.
• Appliances that are obviously damaged must not be operated.
WARNING
!
• Before opening doors and access panels bearing the ultraviolet radiation hazard symbol for the
conducting user maintenance, it is recommended to disconnect the power.
• UV-C barriers bearing the ultraviolet radiation hazard symbol should not be removed.
• Do not operate UV-C lamps outside of the appliance.
• The appliance must be disconnected from the supply before replacing the UV-C lamp.
• Prior to cleaning or other maintenance, the appliance must be disconnected from the supply
mains.
CAUTION
!
• Do not install the unit in potentially explosive atmospheres.
• Only qualified service personnel can carry out the repair work, cleaning and maintenance.
Arrange the lines so that they are not loose.
!
â‘¢Place UVnano Filter Box on
indoor unit.
â‘£After insert UV Module cable into the hole, Connect the
cable to PCB of the indoor unit's control box.
CN_UV LED
UV Module
Cable
⑤Assemble the 4 bracket to the UVnano Filter Box and
tighten 2 screws each.
â‘¥Reassemble all filters in reverse
order.
⑦Reassemble the Side Panel of the UVnano Filter Box and Control box cover of indoor unit in
reverse order.
2 How to install the UVnano Filter Box on the indoor Unit
â‘  â‘¡ â‘¢Remove the Air filters. Make indoor unit stand. Unscrew and detach the
control box cover.
â‘  â‘¡Unscrew and Open the Side Panel. Remove all filters.
Installation/ User guide
Screw (8 EA)
Bracket (4 EA)
UV ModuleSide Panel
Pre-Filter
Main Filter
Installation/User guide
1 UVnano Filter Box Components
Lower Panel
NOTE
• Applicable only to the indoor manufactured after October 2021.
• Only available on Standard III wired remote control (Standard III wired remote controller model
name : PREMTB100, PREMTBB10)
• Pre-Filter : Reusable after washing with water, Main Filter : Replacement recommended within 3-
6 months of use.
* Possible to check the accumulated usage time of Main Filter through Standard III wired remote
controller.
* When replacing Main Filter, additionally checking the status of Pre-Filter is recommended.
• The feature can be changed according to the type of model.
Control Box
Bracket
Screw
UVnano
Filter Box
Indoor Unit
Air Flow
* Pre-Filter : Pre-Filter : Reusable after washing with water, Main Filter : Replacement recommended within 3-6 months of use.
(1) Preparation of the indoor unit.
(2) Preparation of the UVnano Filter Box
Air Filter
Side Panel
Control Box Cover
5 Position of Suspension Bolt
Install the unit above the ceiling correctly.
6 Position of Maintenance Hole
Install the lower or the side maintenance hole to maintain the filter when installing the UVnano Filter
Box. Refer to the indoor unit installation manual of installation intervals.
The place shall be able to maintain the unit as the figure.
Lower Maintenance Hole (750 x 450)
Side Maintenance Hole
(750 x 450)
Drainage hole
Unit: mm
Unit: mm
C
I
F
L
G
E
J
A
B
D
K
Dimension
Chassis name
A B C D E F G H I J K L
M1 933.4 971.6 619.2 700 30 270 15.2 858 201.4 900 980 279
M2 1283.4 1321.6 619.2 700 30 270 15.2 1208 201.4 1250 980 279
M3 1283.4 1321.6 619.2 700 30 360 15.2 1208 291.4 1250 980 279
3 Installer Setting
At the field, select this function when UVnano Filter Box newly installed to the indoor unit or when
UVnano Filter Box is removed.
• Set the following setting values by pressing <, > button.
Function Value
UVnano
Not install / Install
Filter Box
4 User Setting
UVnano is a function that sterilizes fans or filters using UV LEDs at regular intervals during air
conditioning operation.
• Set the following setting values by pressing <, > button.
Function Value
UVnano Not use / Use
CAUTION
!
Make sure to set the 2 functions by proceeding with installer mode.
If you set incorrectly, the air conditioner may malfunction.
UVnano Filter Box
Indoor Unit


Product specificaties

Merk: LG
Categorie: Airco
Model: PBM13M1UA0

Heb je hulp nodig?

Als je hulp nodig hebt met LG PBM13M1UA0 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco LG

LG

LG PM12EP Handleiding

21 December 2024
LG

LG LW1514ER Handleiding

22 November 2024
LG

LG LP1220GSR Handleiding

22 November 2024
LG

LG LW7010HR Handleiding

22 November 2024
LG

LG LP0818WNR Handleiding

22 November 2024
LG

LG LW1011CR Handleiding

22 November 2024
LG

LG C142CM Handleiding

4 November 2024
LG

LG A122CB Handleiding

4 November 2024
LG

LG C182CM Handleiding

4 November 2024
LG

LG C122CC Handleiding

4 November 2024

Handleiding Airco

Nieuwste handleidingen voor Airco