INSTALLATION MANUAL
AIR CONDITIONER
• Please read this installation manual completely before installing the product.
• Installation work must be performed in accordance with the national
wiring standards by authorized personnel only.
• Please retain this installation manual for future reference after reading
it thoroughly.your set and retain it for future reference.
P/NO : MFL67221402
www.lg.com
MODELS : ARUN Series
ARUV Series
ARUN/ARUV Series Outdoor unit Installation Manual
TABLE OF CONTENTS
Safety Precautions................................................................................................................3
Installation Process ..............................................................................................................7
Outdoor units Information....................................................................................................8
Environment-friendly Alternative Refrigerant R410A .....................................................14
Select the Best Location ....................................................................................................14
Installation Space................................................................................................................15
Lifting method .....................................................................................................................17
Installation ...........................................................................................................................18
Refrigerant piping installation ...........................................................................................23
Pipe connections between indoor and outdoor unit.......................................................27
Electrical Wiring ..................................................................................................................53
Test Run ...............................................................................................................................85
New Function ....................................................................................................................111
Caution For Refrigerant Leak...........................................................................................120
Installation guide at the seaside......................................................................................122
2Outdoor Unit2Outdoor Unit
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
nIncorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
nMeanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
Be sure not to do.
Be sure to follow the instruction.
n
n
n
nn Installation
Have all electric work done by a licensed
electrician according to "Electric Facility
Engineering Standard" and "Interior Wire
Regulations" and the instructions given in
this manual and always use a special circuit.
• If the power source capacity is inadequate or
electric work is performed improperly, electric
shock or fire may result.
Ask the dealer or an authorized technician to
install the air conditioner.
• Improper installation by the user may result in
water leakage, electric shock, or fire.
Always ground the product.
• There is risk of fire or electric shock.
Always intstall a dedicated circuit and breaker.
• Improper wiring or installation may cause fire or
electric shock.
For re-installation of the installed product,
always contact a dealer or an Authorized
Service Center.
• There is risk of fire, electric shock, explosion, or
injury.
Do not install, remove, or re-install the unit
by yourself (customer).
• There is risk of fire, electric shock, explosion, or
injury.
Do not store or use flammable gas or
combustibles near the air conditioner.
• There is risk of fire or failure of product.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Prepare for strong wind or earthquake and
install the unit at the specified place.
• Improper installation may cause the unit to
topple and result in injury.
Do not install the product on a defective
installation stand.
• It may cause injury, accident, or damage to the
product.
Installation Manual 3


Product specificaties

Merk: LG
Categorie: Airco
Model: ARUN180LN3

Heb je hulp nodig?

Als je hulp nodig hebt met LG ARUN180LN3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco LG

LG

LG LW1514ER Handleiding

22 November 2024
LG

LG LP1220GSR Handleiding

22 November 2024
LG

LG LW7010HR Handleiding

22 November 2024
LG

LG LP0818WNR Handleiding

22 November 2024
LG

LG LW1011CR Handleiding

22 November 2024
LG

LG C142CM Handleiding

4 November 2024
LG

LG A122CB Handleiding

4 November 2024
LG

LG C182CM Handleiding

4 November 2024
LG

LG C122CC Handleiding

4 November 2024
LG

LG C182CC Handleiding

4 November 2024

Handleiding Airco

Nieuwste handleidingen voor Airco