Lab Gruppen IPX 1200 Handleiding


Lees hieronder de πŸ“– handleiding in het Nederlandse voor Lab Gruppen IPX 1200 (4 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 42 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Third Party Instructions
IPX Series
Item no. TP CI - IPX
V 1.0.0
2IPX Series
Introduction
The Lab.gruppen IPX Series of ampliers can be controlled directly from a Telnet
client over TCP/IP, without running the IPX Controller software. This document
describes how.
Telnet clients
In this document we assume you know the IP address of the unit you want to
address, as well as the telnet user name and password.
If you are running e.g. Windows 10 you might rst need to turn on your Windows
Telnet feature. Please see link for further instructions:
https://social.technet.microsoft.com/wiki/contents/articles/38433.windows-10-
enabling-telnet-client.aspx
Windows
1. Open a Windows Command prompt
2. Type: telnet [unit’s IP address] 23
3. Enter the user name and password
4. Now you are connected.
MAC OS-X
1. Open a Terminal window
2. Click Shell – New Remote Connection...
3. Type: telnet [unit’s IP address] 23
4. Enter the user name and password
5. Now you are connected.
Other platforms
For specic information on how to access IPX Series ampliers using other
platforms, we refer to the associated platforms user manual. Communicating
with IPXs require the use of Telnet protocol.
Controlling Settings
Some examples are available in the help menu from the interface itself.
Type β€œh<enter>” for help, or β€œx<enter>” for some examples.
All settings are addressed by 4 parameters to identify the setting,
as well as a value.
The parameters are:
β€’ Channel: The channel you wish to apply the setting to. Input channels start
at 0 (so input one will be channel 0), output channels start at channel 128
(so output one will be channel 128). For settings that do not need a channel,
set it to zero. Set the channel by typing β€œc[channel] <enter>”, e.g. β€œc0”
then hit enter.
β€’ Index: Some settings have multiple values per channel, and in some cases the
index is used for special cases. When in doubt, set it to zero. Set the index by
typing β€œi[index] <enter”.
β€’ Item: the top level category of the setting. Set it by β€œm[item] <enter>”
β€’ Sub-item: The lower level category of the setting. Set it by β€œn[item] <enter>”
The available settings are:
β€’ Gain: Item 1, sub-item 1. Values are set in steps of 0.01dB, so to set the gain to
1dB, set the value to 100.
β€’ Mute: Item 2, sub-item 2. 1=mute, 0=unmute.
β€’ Command: Item 3, sub-item 3. The command is selected by setting the index
to the command number. See below for available commands.
β€’ Select Preset: Item 4, sub-item 4. To load a preset, select the preset number
using this setting, then send the β€œLoad Preset” command.
The available commands are:
β€’ Go to standby: 4
β€’ Exit standby: 5
β€’ Load preset: 1
β€’ Locate (Ping): 6
To enter the value, type β€œv[value] <enter>”.
After setting the desired item and value,
it must be executed by typing β€œe <enter>”
Third Party Instructions 3
Comand matrix > > > > > >
Function Item Sub item Channel Index number Value Execute
Gain: m1 n1 e.g. β€œc128” – e.g. β€œv120” (1,2 dB) e
Mute m2 n2 e.g. β€œc128” – ev1
Unmute m2 n2 e.g. β€œc128” – ev0
Go to standby – – em3 n3 i4
Exit standby – – em3 n3 i5
Locate (ping) m3 n3 – – ei6
Select preset m4 n4 – – β€œv1 - 100” e
Load preset m3 n3 – – ei1
Input channel 1 Input channel 2 No specic channelOutput channel 1 Output channel 2
Channels c0 c0c1 c128 c129
Gain values Values are set in steps of 0.01 dB, so to set the gain to 1,2 dB, set the value to 120.


Product specificaties

Merk: Lab Gruppen
Categorie: Receiver
Model: IPX 1200

Heb je hulp nodig?

Als je hulp nodig hebt met Lab Gruppen IPX 1200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Lab Gruppen

Handleiding Receiver

Nieuwste handleidingen voor Receiver