INSTALLATION INSTRUCTIONS
Read these instructions completely
and carefully.
IMPORTANT- Save these
instructions for local inspector s use.
IMPORTANT- Observe all
governing codes and ordianaces.
Note to Consumer-Keep these
instructions for futrue reference.
Note to Installer-Be sure to leave these
instructions with the Consumer.
Completion time-Approximately 1 hour.
Skill level-Installatio of this appliance
requires basic mechanical skills.
We recommend that two people install
this product.
Proper installation is the responsibility
of the installer.
Product failure due to improper installation
is not covered under the Warranty.
You MUST use all supplied parts and use
proper installation procedures as described
in these instructions when installing this air
conditioner.
BEFORE YOU BEGIN
Do not, under any circumstances, cut or
remove the third (ground) prong from the
power cord.
CAUTION
Do not change the plug on the power cord
of the air conditioner.
Aluminum house wiring may present special
problems- consult a qualified electircian.
When handling unit, be careful to avoid cuts from
sharp metal edges and aluminum fins on front and
rear coils.
TOOLS YOU WILL NEED
Screwdriver
Level
TOOLS YOU MAY USE
Screwdriver
Pencil
Ruler or tape measure
Scissors or knife
Save Carton and these Installation Instructions
for future reference. The carton is the best way
to store unit during winter, or when not in use.
NOTE:
H
Your air conditioner is designed to install in
standard double hung windows with opening
widths of 23 to 36 inches(584mm to 914mm) .
WINDOW REQUIREMENTS
Model
H
600 0~8000Btu/ h 10000~12000Btu/h
14 (356mm) 15-1/2 (394mm)
Table 1
Fig.C
NOTE: The top rail hardware and the Fig.A,
Fig.B and Fig.C are not applicable to the units
more than 10000B tu/h.Before installing unit,
the top rail must be assembled on the unit (For
<10000Btu/h models only).
5
INSTALLATION INSTRUCTIONS
Lower sash must open sufficiently to allow a clear
vertical opening (H) of following size (see Table 1).
Side louvers and the rear of the AC must have clear
air space to allow enough airflow through the
condenser,for heat removal. The rear of the unit must
be outdoors, not inside a building or garage.
PREPARE THE WINDOW
3/4 (or 1/ )
Scre ws
(7)
2Lock Frame
(2)
Sash Lock
(1)
Mounting Hardware
Wind ow sash
seal foam
(1)
PREPARE AIR CONDITIONER
A: Remove the air conditioner from the carton and
place on a flat surface.
B: Remove top rail from the packaging material as
shown in Fig. A.
Top Rail Hardware
3/8 Scre ws
(4)
Top Rail
(1)
Packaging
Fig.A
Top Rail
C: Align the hole in the top rail with those in the top
of the unit as shown in Fig.B
D: Secure the top rail to the unit with the 3/8 Screws
as shown in Fig.C.
For safety reasons, all four(4) screws MUST
be securely fastened.
NOTE:
INSTALL THE ACCORDION PANELS
NOTE: Top rail and Sliding Panels at each side are
offset to provide the proper pitch to the rear of (5/16 ).
This is necessary for proper condensed water
utilization and drainage. If you are not using the Side
Panels for any reason, this pitch to the rear must be
maintained.
A.Place unit on floor, a bench or
a table. Hold the Accordion
Panel in one hand and gently
pull back the center to free the
open end. See Fig.1
Fig.1
Fig.B
6
INSTALLATION INSTRUCTIONS
SECURE THE ACCORDION PANE LS
B. Slide the free end " " section of the panel directly
into the cabinet as shown in Fig. 2. Slide the panel
down. Be sure to leave enough space to slip the
top and bottom of the frame into the rails on the
cabinet.
â… 
Fig. 2
" "s ectionâ… 
C. Once the panel has been installed on the side of
the cabinet, make sure it sits securely inside the
frame channel by making slight adjustments.
Slide the top and bottom ends of the frame into the
top and bottom rails of the cabinet. Fig.3.
D. Slide the panel all the way in and repeat on the
other side.
Top Rail
Bottom Rail
Fig.3
A.Keep a firm grip on the air conditioner, carefully
place the unit into the window opening so the bottom
of the air conditioner frame is against the window
sill (Fig.5). Carefully close the window behind the top
rail of the unit.
Fig.5
NOTE: Check that air conditioner is tilted back about
H (Fig.5)(tilted about 3 to 4 downward to the outside).
After proper installation, condensate should not drain
from the overflow drain hole duringnor mal use, correct
the slope otherwise.
O O
B.Extend the side panels out against the window
frame (Fig.6).
window
frame
Fig.6
INSTALL SUPPORT BRACKET
A.Place the frame lock between the frame
extensions and the window sill as shown(Fig.7).
Drive 3 / 4 (19mm)o r 1 locki ng screw s
through the frame lock and into the sill .
: To prevent window sill from splitting,drill
1 / 8" (3mm) pilot holes before driving screws.
NOTE
/ 2 "(12.7mm)
"
Fig.7
If storm w indow bl ocks AC, see Fig. 11.NOTE:
Top Rail
Bottom Rail
Top left
Top right
Fig.4
Wooden Windows
INSIDE
OUTSIDE
H:A bout 3 /4 to 1 for 5 to 8K );(
Measure from the cabinet edge
H:Abo ut 1 to 1 / for 10 to12K );
3
8
(
H