Indesit IP 641 S C IX Handleiding

Indesit Fornuis IP 641 S C IX

Lees hieronder de 📖 handleiding in het Nederlandse voor Indesit IP 641 S C IX (12 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 36 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
HOB
IP 640 S UK
IP 641 S C UK
IP 751 S C UK
Contents
Installation, 2-5
Positioning
Electrical connection
Gas connection
Data plate
Burner and nozzle specifications
Description of the appliance, 6
Overall view
Start- anup d use, 7
Practical advice on using the burners
Precautions an tid ps, 8
General safety
Disposal
Maintenance and care, 9
Switching the appliance off
Cleaning the appliance
Gas tap maintenance
Troubleshooting, 10
Operating Inst tionsruc
GB
Eng hlis , 1
GB
GB
2
Before operating your new appliance please read this
instruction booklet carefully. It contains important information
for safe use, installation and care of the appliance.
Please keep these operating instructions for future
reference. Pass them on to possible new owners of the
appliance.
Positioning
Keep packaging material out of the reach of children. It
can become a choking or suffocation hazard (see
Precautions and tips).
The appliance must be installed by a qualified professional
according to the instructions provided. Incorrect installation
may cause harm to people and animals or may damage
property.
This unit may be installed and used only in permanently
ventilated rooms in accordance with British Standard Codes
Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S. 6891
Current Editions. The following requirements must be
observed:
The room must be equipped with an air extraction system
that expels any combustion fumes. This may consist of a
hood or an electric fan that automatically starts each time
the appliance is switched on.
The room must also allow proper air circulation, as air is
needed for combustion to occur normally. The flow of air
must not be less than 2 m3/h per kW of installed power.
The air circulation system may
take air directly from the outside
by means of a pipe with an inner
cross section of at least 100 cm2;
the opening must not be
vulnerable to any type of
blockages.
The system can also provide the
air needed for combustion
indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as
described above. However, these
rooms must not be communal
rooms, bedrooms or rooms that
may present a fire hazard.
Liquid petroleum gas sinks to the floor as it is heavier
than air. Therefore, rooms containing LPG cylinders must
also be equipped with vents to allow gas to escape in
the event of a leak. As a result LPG cylinders, whether
partially or completely full, must not be installed or
stored in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the
cylinder being used in the room, positioned so that it is
not subject to heat produced by external sources
(ovens, fireplaces, stoves, etc. ) which could raise the
temperature of the cylinder above 50°C.
Fitting the appliance
Gas and mixed hobs are manufactured with type X
degree protection against overheating. The following
precautions must be taken when installing the hob:
Kitchen cabinets adjacent to the appliance and taller
than the top of the hob must be at least 600 mm from
the edge of the hob.
Hoods must be installed according to their relative
installation instruction manuals and at a minimum
distance of 650 mm from the hob.
Place the wall cabinets adjacent to the hood at a
minimum height of 420 mm from the hob (see figure).
If the hob is installed beneath a
wall cabinet, the latter must be
situated at a minimum of 700 mm
above the hob (see figure).
The installation cavity should have the dimensions
indicated in the figure. Fastening hooks are provided,
allowing you to fasten the hob to tops that are between
20 and 40 mm thick. To ensure the hob is securely
fastened to the top, we recommend you use all the
hooks provided.
555
mm
475
mm
55
mm
Hoo fastening diagrak m
Hooking position Hooking position
for top H=20 mm for top H=30 mm
Installation
Enlarging the ventilation slot
between window and floor.
Adjacent
Room
Room to be
Vented
A
Examples of ventilation holes
for comburant air.
In a chimney stack or branched flue.
(exclusively for cooking appliances)
Directly to
the Outside
600mm min.
600mm min.
700mm min.
G B
3
Front
Hooking position Back
for top H=40 mm
Use the hooks contained in the accessory pack
Where the hob is not installed over a built-in oven, a
wooden panel must be installed as insulation. This
must be placed at a minimum distance of 20 mm from
the lower part of the hob.
Ventilation
To ensure adequate ventilation, the back panel of the
cabinet must be removed. It is advisable to install the
oven so that it rests on two strips of wood, or on a
completely flat surface with an opening of at least 45 x
560 mm (see diagrams).
! The hob can only be installed above built-in ovens with a
cooling ventilation system.
Electrical onne c ction
The cooktops fitted with a tripolar electrical supply
cord are designed to be be used with alternating
current according to the indications on the rating
plate located under the cooktop. The earthing wire
can be identified by its yellow-green colour.
In the case of installation over a built-in electric
oven, the electrical connections for the cooktop and
oven should be independent, not only for safety
purposes, but also to facilitate removal of one or
both in the future.
Elec rical ec Gast Conn t oion f r Coo tokp
Fit the supply cord with a standard plug for the
demand rate indicated on the rating plate or connect
it directly to the electrical mains. In the latter case, a
single pole switch must be placed between the
appliance and the mains, with a minimum opening
between the contacts of 3 mm in compliance with
current safety codes (the earthing wire must not be
interrupted by the switch). The power supply cord
must be positioned so that it does not reach a
temperature in excess of 50°C above room
temperature at any point.
The installer must ensure that the correct electrical
connection has been made and that it is compliant
with safety regulations.
Before making the actual connection, make sure
that:
The fuse and electrical system can withstand the
load required by the appliance;
That the electrical supply system is equiped with
an efficient earth hook-up according to the norms
and regulations prescribed by law;
That the plug or switch is easily accessible.
The wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
As the colours of the wires in the mains lead may
not correspond with the coloured markings
identifying the terminals in your plug, proceed as
follows:
Connect the Green & Yellow wire to the terminal
marked Eor or coloured Green or Green &
Yellow.
Connect the Brown wire to the terminal marked Lor
coloured Red.
Connect the Blue wire to the terminal marked Nor
coloured Black.
The cable must not be bent or compressed.
The cable must be checked regularly and replaced
by authorised technicians only (see Assistance).
The manufacturer declines any liability should
these safety measures not be observed.
Gas onne c ction
The appliance should be connected to the main gas supply
or to a gas cylinder in compliance with current national
regulations. Before carrying out the connection, make sure
the cooker is compatible with the gas supply you wish to
560 mm.
45 mm.


Product specificaties

Merk: Indesit
Categorie: Fornuis
Model: IP 641 S C IX
Apparaatplaatsing: Ingebouwd
Soort bediening: Draaiknop
Kleur van het product: Roestvrijstaal
Breedte: 590 mm
Diepte: 510 mm
Hoogte: 33 mm
Vermogen brander/kookzone 2: 1650 W
Vermogen brander/kookzone 3: 3500 W
Vermogen brander/kookzone 1: 1650 W
Aantal branders/kookzones: 4 zone(s)
Type kookplaat: Gaskookplaat
Electronische ontsteking: Ja
Type brander/kookzone 1: Regulier
Type brander/kookzone 2: Regulier
Type brander/kookzone 3: Wok
Aantal gaspitten: 4 zone(s)
Aantal elektronische kook zones: 0 zone(s)
Vermogen: 7800 W
Veiligheidsklep: Ja
Type brander/kookzone 4: Sudderen
Vermogen brander/kookzone 4: 1000 W
Voedingsbron brander/kookzone 1: Gas
Voedingsbron brander/kookzone 2: Gas
Voedingsbron brander/kookzone 3: Gas
Voedingsbron brander/kookzone 4: Gas
Positie brander/kookzone 1: Links voor
Diameter brander/kookzone 1: 75 mm
Positie brander/kookzone 2: Links achter
Diameter brander/kookzone 2: 75 mm
Positie brander/kookzone 3: Rechts achter
Diameter brander/kookzone 3: 110 mm
Positie brander/kookzone 4: Rechts voor
Diameter brander/kookzone 4: 55 mm
Kookzone 1 vorm: Rond
Kookzone 2 vorm: Rond
Kookzone 3 vorm: Rond
Kookzone 4 vorm: Rond