www.HunterFan.com 1.888.830.1326
PA G E
5
30 inches
7 feet
PA G E
2
What to Expect with
Your Installation Ceiling Bracket
Ladder
PA G E
3
Tools Needed
Troubleshooting
Table of Contents
PA G E
4
Mounting Options
?
?
?
PA G E
23
Congratulations on purchasing your new Hunter® ceiling fan! It will
provide comfort and performance in your home or ofce for many
years. This installation and operation manual contains complete
instructions for installing and operating your fan.
We are proud of our work and appreciate the opportunity to supply
you with the best ceiling fan available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
PA G E
15
Switch Housing
PA G E
7
PA G E
11
Wiring
PA G E
8
DownrodPreparation Blades
PA G E
14
Canopy
PA G E
13
Light Kit
PA G E
16
PA G E
20
Remote Control
PA G E
18
Operation, Maintenance
& Cleaning Uninstalling the
Light Kit
PA G E
22
Energy Star
PA G E
22
1
M3562-01 • 12/17/14 • © Hunter Fan Company
www.HunterFan.com
1.888.830.1326
M3562-01 • 12/17/14 • © Hunter Fan Company
1.888.830.13261.888.830.1326
What to Expect with Your Installation
2
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
76.2 cm / 30
in / 30 po
from blade tip
to nearest wall
or obstruction
2.15 m /
7 ft / 7 pi
from bottom
edge of blade
to the oor
Select a downrod lengthAssess ceiling angle
Must be able to
secure the fan to
building structure or
fan-rated outlet box
1
2
3
Standard Downrod
for ceilings 2.4-3 m / 8-10 ft /
8-10 pi high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 10 feet / 3 meters
or higher
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
w.1 - To reduce the risk of re, electrical shock, or personal
injury, mount fan directly from building structure and/or an
outlet box marked acceptable for fan support of 70 lbs (31.8 kg)
and use the mounting screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or
servicing your fan, disconnect the power by turning off the
circuit breakers to the outlet box and associated wall switch
location. If you cannot lock the circuit breakers in the off
position, securely fasten a prominent warning device, such as a
tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage,
use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade
brackets when installing the blade brackets, balancing the blades,
or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring,
use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and if not
installed and used in accordance with the instructions may cause
harmful interference to radio communications.
This product may cause interference to radio equipment and
should not be installed near maritime safety communications
equipment, ships at sea, or other critical navigation or
communications equipment operating between 0.45-30 MHz.
This device complies with Part 18 of the FCC Rules.
www.HunterFan.com
1.888.830.1326
Tools Needed
Ladder ScrewdriversPliers Wire Strippers
Power Drill
(optional)
.36 cm / 9/64 in /
9/64 po Drill Bit
(optional)
If mounting to a support structure, you will also need these tools.
.87 cm / 11/32
in / 11/32 po
Wrench
3
M3562-01 • 12/17/14 • © Hunter Fan Company


Product specificaties

Merk: Hunter
Categorie: Ventilator
Model: Sable Ridge

Heb je hulp nodig?

Als je hulp nodig hebt met Hunter Sable Ridge stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Hunter

Hunter

Hunter Bennett Handleiding

11 November 2024
Hunter

Hunter Gravity Handleiding

11 November 2024
Hunter

Hunter Minimus Handleiding

11 November 2024
Hunter

Hunter Neuron Handleiding

11 November 2024
Hunter

Hunter Rogers Handleiding

11 November 2024
Hunter

Hunter Rhinebeck Handleiding

11 November 2024
Hunter

Hunter Hardwick Handleiding

11 November 2024
Hunter

Hunter Swanson Handleiding

11 November 2024

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator