Installation Manual
Type
Enclosed Type Switching Power Supply
(Families: G3, NE, LRS, SE, PFC, HSP, SPV, USP, RST, G5, MSP)
Introduction
Enclosed type switching power supplies possess a metal or plastic case for covering their internal PCB and will be
installed inside the case of the end system. Mean Well’s enclosed type power supplies include 2 different groups of
power supplies, with built-in fan and without built-in fan, depending on their rated power or design concept.
Installation
( )1 Before any installation or maintenance work, please disconnect your system from the utility.
Ensure that it can’t be re-connected inadvertently!
( )2 Keep enough insulation distance between mounting screws and internal components of power supplies. Please
refer to case drawing on specifications to receive the maximum length of mounting screw.
( )3 Mounting orientations other than standard orientation or operate under high ambient temperature may
increase the internal component temperature and will require a de-rating in output current. Please refer to
the specification sheets to receive the optimum mounting position and information about the de-rating curve.
( )4 Fans and ventilation holes must be kept free from any obstructions. Also a 10-15 cm clearance must be kept
when the adjacent device is a heat source.
( )5 Input and Output terminal
Terminal Screw
Series Screw Size Suggested
Torque
RSP-750 / 1000 / 1500 / 2000 / 2400 / 3000
SE-450 / 1000 / 1500
HEP-600 MSP-300 HRP-300HRPG-300
SP-480SP-750SPV-1500USP-500RST-10000
M4 10-12kgf-cm
HRP-075 / 100 / 150 / 200HRPG-150 / 200
LRS-035 / 050 / 075 / 100 / 150 / 150F / 200 / 350
MSP-100 / 200
NED-035 / 050 / 075 / 100NET-035 / 050 / 075
NES-025 / 035 / 050 / 075 / 100 / 150 / 200 / 350
QP-200 / 320 / 375
RD-050 / 065 / 085 / 125RID-050 / 065 / 085 / 125
RS-035 / 050 / 075 / 100 / 150
RSP-075 / 100 / 150 / 200 / 320
SP-075 / 100 / 150 / 200 / 240 / 320SPV-150/300
SE-100 / 200 / 350HSP-250PSP-600
M3.5 8-10 kgf-cm
RSP-1600
RD-035RT-050 / 065 / 085 / 125
RQ-050 / 065 / 085 / 125
TP-075 / 100 / 150QP-100 / 150
RS-015 / 025
NES-015USP-150
M3 6-8 kgf-cm
ERP-350
HDP-190 / 240
NEL-200 / 300
#6 8-10 kgf-cm
Installation Manual
Terminal Screw
Series
Input Output
Screw Size Suggested
Torque Screw Size Suggested
Torque
HRP-450 / 600
HRPG-450 / 600
MSP-450 / 600
SE-600
M3 6-8kgf-cm M4 10-12kgf-cm
HSP-150 / 200 /300
HSN-200 / 300 M3 6-8kgf-cm M3.5 8-10kgf-cm
RSP-500 M3.5 8-10kgf-cm M4 10-12kgf-cm
RST-5000 M4 10-12kgf-cm 10-12kgf-cm M8
NEL-400 #6 8-10kgf-cm M3 8-10kgf-cm
( )6 Recommended wires are shown as below.
AWG 18 16 14 12 10 8
Rated Current of
Equipment (Amp) 6A 6-10A 10-16A 16-25A 25-32A 32-40A
Cross-section of
Lead(mm2 ) 0.75 1.00 1.5 2.5 4 6
Note: Current each wire carries should be de-rated to 80% of the current
suggested above when using 5 or more wires connected to the unit.
Make sure that all strands of each stranded wire enter the terminal connection and the screw terminals are
securely fixed to prevent poor contact.
( )7 For other information about the products, please refer to www.meanwell.com for details.
Warning / Caution !!
( )1 Risk of electrical shock and energy hazard. All failure should be examined by a qualified technician. Please do
not remove the case of the power supply by yourself!
( )2 Please do not install power supplies in places with high moisture or near the water.
( )3 Please do not install power supplies in places with high ambient temperature or near fire source. The
maximum ambient temperature please refer to their specifications.
( )4 Output current and output wattage must not exceed the rated values on specifications.
( )5 The ground(FG) must be connected to earth ground.
( )6 All MW’s PSUs are designed in accordance with EMC regulations and the related test reports are available by
request. Since they are belong to component power supplies and will be installed inside system enclosure,
when they are integrated into a system, the EMC characteristics of the end system must be re-verified again.
Installation Manual
Manufacturer
MEAN WELL ENTERPRISES Co., LTD.
No.28, Wuquan 3rd Rd., Wugu Dist.,
New Taipei City 24891, Taiwan
Tel: +886-2-2299-6100
Web: www.meanwell.com
Branch Office
China
MEAN WELL (GUANGZHOU)
ENTERPRISES Co., LTD.
2F, A Building, Yuean lndustry Park,
Huangcun,Dongpu Yown, Tianhe
District, Gungzhou, China
Post Code:510660
Tel: +86-20-2887-1200
Web: www.meanwell.com.cn
U.S.A.
MEAN WELL USA, INC.
44030 Fremont Blvd., Fremont,
CA 94538, U.S.A.
Tel: +1-510-683-8886
Web: www.meanwellusa.com
Europe
MEAN WELL EUROPE B.V.
Langs de Werf 8, 1185XT
Amstelveen, The Netherlands
Tel: +31-20-758-6000
Web: www.meanwell.eu


Product specificaties

Merk: Hunter
Categorie: Ventilator
Model: Raefield

Heb je hulp nodig?

Als je hulp nodig hebt met Hunter Raefield stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ventilator Hunter

Hunter

Hunter Bennett Handleiding

11 November 2024
Hunter

Hunter Gravity Handleiding

11 November 2024
Hunter

Hunter Minimus Handleiding

11 November 2024
Hunter

Hunter Neuron Handleiding

11 November 2024
Hunter

Hunter Rogers Handleiding

11 November 2024
Hunter

Hunter Rhinebeck Handleiding

11 November 2024
Hunter

Hunter Hardwick Handleiding

11 November 2024
Hunter

Hunter Swanson Handleiding

11 November 2024

Handleiding Ventilator

Nieuwste handleidingen voor Ventilator

Livoo

Livoo DOM510 Handleiding

20 December 2024
Orava

Orava SF-13 Handleiding

18 December 2024
EMOS

EMOS P56PR2 Handleiding

14 December 2024
Midea

Midea FTS30-13AR Handleiding

14 December 2024
Midea

Midea FTS35-9AR Handleiding

14 December 2024
Midea

Midea FTS30-9AR Handleiding

14 December 2024