Please read this manual before using the air conditioner.
Keep this manual for future reference.
PACKAGED TYPE ROOM AIR CONDITION
OPERATION MANUAL AND INSTALLATION MANUAL
ER
h
s
i
l
g
n
E
This appliance is filled with R32.
AP71DFCHRA/1U71RECFRA
AP24DFCHRA/1U24RECFRA
0011509384
Contents
11
12
21
PARTS AND FUNCTIONS
OPERATION............................................................................................................................
INDOOR AND OUTDOOR UNIT INSTALLATION..................................................................
MAINTENANCE 25
19
CAUTIONS.............................................................................................................................
.......................................................................................................
TROUBLE SHOOTING........................................................................................................... 20
................................................................................
WARNING:
·If the supply cord is damaged, it must be replaced by the manufacturer,its service agent or
similarly qualified persons in order to avoid a hazard.
·
·All the cables shall have got the European authentication certificate. During installation, when the
·connecting cables break off, it must be assured that the grouding wire is the last one to be broken off.
The explosion-proof breaker of the air conditioner should be all-pole switch. Distance between its two
contacts should be not less than 3mm. Such means fordisconnection must be incorporated in the
·Make sure installation is done according to local wiring regulation by professional persons.
·
·A leakage explosion-proof breaker must be installed.
Make sure ground connection is correct and reliable.
Read the precautions in this manual
carefully before operating the unit. This appliance is filled with R32.
Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
·
Keep this manual where the user can easily find it.
The appliance must be stored in a room without continuously operating ignition sources (for
example: open flames, an operating gas appliance or an operating electric heater).
Do not pierce or burn.
·
·Be aware that refrigerants may not contain an odour.
·The appliance must be installed, operated and stored in a room with a floor area larger than
3m.
·
·Do not use a refrigerant other than the one indicated on the outdoor unit(R32) when installing,
moving or repairing. Using other refrigerants may cause trouble or damage to the unit, and
personal injury.
wiring.
2
1
This appliance can be used by children aged 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and
knowledge if they have been given superivision or instruction concering use of the
appliance in a safe way and understand the hazards involved. Children shall not play with
the appliance.
The appliance shall be installed in accordance with national wiring regulations
h
s
i
l
g
n
E
AND WIFI FUNCTION
Loading and Unloading/Transporting Management/Storage Requirements
1) The products shall be carefully handled during loading and unloading.
2) Rude and barbarous handling such as kicking, throwing, dropping, bumping, pulling and rolling is not
allowed.
3) The workers engaged in loading and unloading must be subject to necessary trainings on the potential
hazards caused by barbarous handling.
4) Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped at the loading and unloading site.
5) The untrained personnel cannot be engaged in loading and unloading of flammable refrigerants air
conditioner.
6) Before loading and unloading, anti-static measures shall be taken, and phones cannot be answered during
loading and unloading.
7) Smoking and open fire are not allowed around the air conditioner.
Transporting Management Requirements
1) The maximum transporting volume of finished products shall be determined as per local regulations.
2) The vehicles used for transporting shall be operated as per local laws and regulations.
3) Dedicated after-sales vehicles shall be used for maintenance, and exposed transporting of refrigerant
cylinders and the products to be maintained is not allowed.
4) The rain cover or similar shielding material of transporting vehicles shall be provided with certain flame
retardancy.
5) Leakage warning device of flammable refrigerant shall be installed inside the closed-type compartment.
6) Anti-static device shall be equipped inside the compartment of transporting vehicles.
7) Dry powder extinguishers or other suitable fire extinguishing apparatus within the period of validity shall be
equipped inside the driver's cab.
8) Orange-white or red-white reflective stripes shall be pasted on the sides and tail of the transporting vehicles,
to remind the vehicles behind of keeping distance.
9) The transporting vehicles shall run at a constant speed, and heavy acceleration/deceleration shall be avoided.
10) Combustibles or the static articles cannot be transported simultaneously.
11) High-temperature area shall be avoided during transporting, and necessary radiating measures shall be taken
in case the temperature inside the compartment is too high.
Storage Requirements
1) The storage package of equipment used shall be such that no leakage of refrigerant will be caused due to
mechanical damage of the equipment inside.
2) The maximum quantity of the equipment allowed to be stored together shall be determined as per local
regulations.
Installation Instructions
WARNING!
The area of the room in which R32 refrigerant air conditioner is installed cannot be less than the minimum
area specified in the table below, to avoid potential safety problems due to out-of-limit of refrigerant
concentration inside the room caused by leakage of refrigerant from refrigeration system of the indoor unit.
Once the horn mouth of connecting lines is fastened, it may not be used again (the air tightness may be
affected).
A whole connector wire shall be used for indoor/outdoor unit as required in the operation specification of
installation process and operation instructions.
Minimum Room Area
Type LFL
kg/m3
Total Mass Charged/kg
Minimum Room Area/m2
R32 0.306
1.224 1.836 2.448 3.672 4.896 6.12 7.956
3 6 13 23 36 60
2
The maximum refrigerant charge amount (M)
Unit model M kg Unit model M kg Unit model M kg Unit model M kg
1U20YEEFRA 0.62 1U25S2SM1FA 0.85 1U35MEEFRA 0.82 1U50JEFFRA-TCS 1.35
1U25BEEFRA 0.74 1U25YEMFRA 0.67 1U35S2PJ1FA 1.15 1U50MEE/MFRA 1.30
1U25BEFFRA 0.90 1U35BEEFRA 0.82 1U35S2SM1FA 1.14 1U50S2SJ2FA 1.35
1U25BEFFRA-TCS 0.90 1U35BEEFRA-TCS 0.82 1U35YEMFRA 0.70 1U68REE/F/MFRA 1.60
1U25S2PJ1FA 1.15 1U35BEFFRA 0.92 1U50JEFFRA 1.35 1U71S2SR1FA 1.60
1U42S2SM1FA 1.14 1U50S2PR1FA 1.60 1U25JEJFRA 1U35JEJFRA
1U50REJFRA 1.60
0.94 0.94
1U71REAFRA
1.60
h
s
il
g
nE
1U71RECFRA