Gree 26TTW09AC115V1A Handleiding

Gree Airco 26TTW09AC115V1A

Lees hieronder de đź“– handleiding in het Nederlandse voor Gree 26TTW09AC115V1A (16 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 38 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
TTW Air Conditioner
Thank you for choosing our product.
For proper operation, please read and keep this manual carefully.
26TTW09AC115V1A 26TTW09HP115V1A
26TTW12AC115V1A 26TTW09AC230V1A
26TTW09HC230V1A 26TTW07HP230V1A
26TTW09HP230V1A 26TTW12AC230V1A
26TTW12HC230V1A 26TTW12HP230V1A
Models
2
TABLE OF CONTENTS
Important Note to Homeowner ................................................... 2
Important Note to Servicer .......................................................... 2
Operating Instructions ................................................................ 2
Unit Features .............................................................................. 2
Installation Instructions .............................................................. 3
Wiring .......................................................................................... 6
Air Conditioner Features ............................................................ 7
Remote Control .......................................................................... 7
Additional Information .............................................................. 13
Normal Operating Sounds and Conditions ............................. 13
Obtaining Service ..................................................................... 13
IMPORTANT NOTE TO THE HOMEOWNER
This manual is to be used by qualified, professionally trained HVAC
technicians only. Gree does not assume any responsibility
for property damage or personal injury for improper service proce-
dures or services performed by an unqualified person.
IMPORTANT NOTE TO THE SERVICER
Read this manual and familiarize yourself with the specific items
which must be adhered to before attempting to service this unit.
The precautions listed in this Installation Manual are intended as
supplemental to existing practices. However, if there is a direct
conflict between existing practices and the content of this manual,
the precautions listed here take precedence.
OPERATING INSTRUCTIONS
Check the data specification plate and ensure the proper voltage
and current rating is available for the type power plug on the unit.
DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER
CORD. Note the types of acceptable plugs on the following figure.
Refer to the data specification plate for electrical requirements.
UNIT FEATURES
This unit has many features which are different than those found
on conventional units. The servicer must be familiar with these
features in order to properly service the unit.
Check the data specification plate and ensure the proper voltage
and current rating is available for the type power plug on the unit.
DO NOT REMOVE THE GROUNDING PRONG FROM THE POWER
CORD. Note the types of acceptable plugs in Figure 1. Do not use
an extension cord for the installation of this product. Refer to the
data specification plate for electrical requirements.
120V
15 Amp
208/230V
1 Amp5
208/230V
20 Amp
Figure 1
•LCDI or AFCI Power Cords - Underwriters Laboratories and
the National Electric Code (NEC) now require power cords
that sense current leakage and can open the electrical cir-
cuit to the unit on units rated at 250 volts or less. In the event
that unit does not operate, check the reset button located on
or near the head of the power cord as part of the normal
troubleshooting procedure.
LCDI Power Cord
Figure 2
Product Warranty .......................................................................14
3
VOLTAGE MEASUREMENTS
Before connecting the unit, measure the supply voltage. Voltage
must fall within the voltage utilization range given in the following
table.
Unit Voltage
Rating Minimum Maximum
230/280 187 253
115 103 126
Voltage Utilization Range
Operating Voltage
INSTALLATION INSTRUCTIONS
To ensure that the unit operates safely and efficiently, it must be
installed, operated, and maintained according to these installa-
tion and operating instructions and all local codes and ordinances,
or, in their absence, with the latest edition of the National Electrical
Code. The proper installation of this unit is described in the follow-
ing sections. Following the steps in the order presented should
ensure proper installation.
SLEEVE INSTALLATION
In order for condensate water to drain properly inside the unit, the
sleeve must be installed properly:
• Level from right to left.
• A slight downward pitch from the indoor side to the outdoor
side as shown in Figure 3.
Refer to the Installation Instructions supplied with the wall sleeve
for a complete description of the installation procedure.
NOTE: Wall sleeve is not shipped with chassis and
must be purchased separately.
Wall
Sleeve
Outside
Wall
OutsideInside Level
1/4 Bubble
Tilt To
Outside
Figure 3
CHASSIS INSTALLATION
1. Remove front grille. See Figure A.
Filter Handle
Lift up on
Figure A
The front grille can be removed for more thorough cleaning or to
make the model and serial numbers accessible. To remove, pull
the filter out and remove the four grille screws.
Grille
Tab
Pull the grille out from the bottom and lift up from the tabs on the
top of the case.
2. Remove the grounding screw and wire next to the grounding
symbol on right side of chassis control panel (Figure 3). At-
tach other end of ground wire to the hole in the bottom right
side of the sleeve with #8 x 3/8” blunt point sheet metal screw.
The hole on the sleeve is indicated by grounding symbol on
the sleeve. Slide chassis part of the way into the sleeve and
reattach the ground wire back to the hole on the right side on
the control panel area next to the grounding symbol.