Made in Italy AC 2784 Rev. 04 - 12/11
UK
INSTALLATION AND
USE MANUAL
INSTALLATION CERTIFICATE
The undersigned qualified installer attests having personally fitted the here described vehicle
security system following the manufacturer instructions.
................................................
..........................................................................................................................
By :
Sold on : T :ype of product
V :ehicle
SERIE 933
933
932
933
932
GEMINI Technologies S.p.A.
Via Luigi Galvani 12 - 21020 Bodio Lomnago (VA) - Italia
Tel. +39 0332 943211 - Fax +39 0332 948080
Web site: www.gemini-alarm.com
Reg. n.532-A
UNI EN ISO 9001:2008
PAGE 02
1.0 - PRELIMINARY ADVICE
Dear Customer, th
.
same as 933 without self-powered battery.
:
GEMINI 932:
e present manual illustrates the most fully featured alarm system; not all functions,
electrical connections etc. will therefore apply to all models.
Before installing, identify your alarm model and refer to it for the correct instructions
The following signs, intended for the installer or the user, indicate particular functions or connections
as follows
USER MANUAL - PAGE 03
TABLE OF CONTENTS
For the installer.
This sign indicates that the system will work according to the connections and the
programming selected or it simply provides useful installation tips.
!
For the user.
This sign highlights useful information.
UK
1.0
2.0
4.0
5.0
6.0
7.0
8.0
14.0
15
16.0
17.0
- PRELIMINARY ADVICE.............................................................................................
- OPERATING DESCRIPTION.....................................................................................
2.1 - Complete system arming..........................................................................................
2.2 - System arming with sensor and comfort control exclusion.......................................
2.3 - Passive arming.........................................................................................................
2.4 - Arming inhibit time....................................................................................................
2.5 - System armed..........................................................................................................
2.6 - Alarm, inhibit time between alarms and alarm cycles...............................................
2.7 - System disarming.....................................................................................................
2.8 - Emergency disarming by electronic key...................................................................
2.9 - Alarm memory...........................................................................................................
WARRANTY CONDITIONS ...................................
- WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE) DIRECTIVE.......
- CONNECTORS TABLES............................................................................................
5.1 - 20-way connector.....................................................................................................
5.2 - 8-way connector.......................................................................................................
- COMPLETE ELECTRIC DIAGRAM...........................................................................
- C ............
..........................................................................................
..........................................................
7.3 - Connection to hazard push-button...........................................................................
- SELECTION OF CONNECTIONS TO ARM/DISARM THE SYSTEM........................
..........................
..............................................
8.3 - Connections to turn indicators..................................................................................
8.4 - โMixedโ connection option........................................................................................
SYSTEM PROGRAMMING.............. ....................................
.....................................................................................
.........................................................................
11.3 - Passive arming.......................................................................................................
11.4 - Enabling 5) ........................................................................
11.5 - Door switch polarity selection.................................................................................
11.6 - Optical pulse signal/self-powered siren.
11.7 - Negative output s ................
..............................................
ADDING NEW DEVICES..........................................................................................
- DELETING PROGRAMMED DEVICES...................................................................
..........................................................
..........................................................................
..........................................................................................
- SYSTEM RESET......................................................................................................
- TECHNICAL SPECIFICATIONS...............................................................................
USER MANUAL
INSTALLER MANUAL
3.0
9.0
10.0
11.0
12.0
13.0
.0
- .....................................................
ONNECTION FOR TURN SIGNALS ACTIVATION......................................
7.1 - Standard connections.....
7.2 - Connections for vehicles with separate lines..
8.1 - Connections and management by CAN-BUS line..........................
8.2 - Connections to door lock motor unit...........................
- VEHICLE CODE PROGRAMMING............................................................................
- SELF-LEARNING OF TURN INDICATORS FLASHES............................................
- ....................................
11.1 - Optical signals...................
11.2 - Acoustic signals.............................
of siren (art. 772 output
.................................................................
election (during alarm) for horns or additional siren...
- SYSTEM PROGRAMMING EXAMPLE......................
-
- ULTRASONIC VOLUMETRIC PROTECTION
15.1 - Connections and positioning........
15.2 - Sensor adjustment........
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 03
PAGE 04
PAGE 04
PAGE 04
PAGE 04
PAGE 04
PAGE 05
PAGE 05
PAGE 06
PAGE 06
PAGE 06
PAGE 07
PAGE 08
PAGE 08
PAGE 12
PAGE 12
PAGE 12
PAGE 12
PAGE 12
PAGE 12
PAGE 13
PAGE 13
PAGE 14
PAGE 15
PAGE 16
PAGE 16
PAGE 16
PAGE 16
PAGE 17
PAGE 08
PAGE 08
PAGE 09
PAGE 09
PAGE 09
PAGE 09
PAGE 09
PAGE 10
PAGE 11
PAGE 12
2.0 - OPERATING DESCRIPTION
Exclusion of sensors and comfort feature is bound to each single arming
cycle.
USER MANUAL
2.1 - COMPLETE SYSTEM ARMING
2.2 - SYSTEM ARMING WITH SENSOR AND COMFORT CONTROL EXCLUSION
Press the lock button on the
).
.
To activate this feature, the system should be disarmed and the ignition key turned โOFFโ position;
proceed as follows.
.
.
.
!
!
vehicle original remote control; system arming is confirmed by a siren
chirp (if feature has been modified) and a flash of the turn indicators.
The system has a 30โ pre-arming โneutral timeโ (indicated by the LED turned on steady
The driver can arm the system and exclude the internal volumetric protection and comfort function
Show the electronic key to its receptacle; the LED gives out a quick flash
Close all vehicle doors and press the lock button on the original remote control
System activation is confirmed by the standard optical/acoustic signals!
2.3 - PA
When this function is programmed, the system passively arms approx. 60โ after ignition switch off and
after the last door is closed.
System activation is confirmed by the standard optical/acoustic signals.
SSIVE ARMING
If passive arming is activated, functioning of internal sensors and comfort output
(automatic window roll-up) are excluded.
Opening a door 60โ before the system is armed causes the procedure to interrupt; it is
resumed once the door is closed.
2.4 - ARMING INHIBIT TIME
System inhibit arming time lasts approximately 30โ and is signalled by the LED on;
.
it is possible to exit
the vehicle without triggering any alarm
Product specificaties
Merk: | Gemini |
Categorie: | Auto alarm |
Model: | 933 |
Heb je hulp nodig?
Als je hulp nodig hebt met Gemini 933 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Auto alarm Gemini
15 Januari 2023
13 Juni 2023
12 Juni 2023
9 Juni 2023
15 Januari 2023
15 Januari 2023
7 Juni 2023
15 Januari 2023
4 Juni 2023
3 Juni 2023
Handleiding Auto alarm
- Auto alarm HP
- Auto alarm Audiovox
- Auto alarm Eufab
- Auto alarm GT
- Auto alarm Spy
- Auto alarm Technaxx
- Auto alarm Viper
- Auto alarm Waeco
- Auto alarm Jablotron
- Auto alarm Olympia
- Auto alarm Cobra
- Auto alarm Clifford
Nieuwste handleidingen voor Auto alarm
7 Februari 2024
7 Februari 2024
7 Februari 2024
6 September 2023
30 December 2022
20 Maart 2023
25 April 2023
10 Juli 2023
10 Juli 2023
10 Juli 2023