If you have questions,call 800.626.2000 or visit our website at: www.monogram.com
Installation
Instructions
36” Chimney Vent Hood
ZV800
Safety Information
2
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT —Save these instructions for
local inspector’s use.
• IMPORTANT —Observe all governing
codes and ordinances.
•Note to Installer —Be sure to leave these
instructions with the Consumer.
•Note to Consumer —Keep these instructions
with your Owner’s Manual for future reference.
•Skill Level —Installation of this appliance requires
basic mechanical and electrical skills.
•Completion Time — 1 to 3 Hours.
•Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered
under the warranty.
For Monogram local service in your area, 1.800.444.1845.
For Monogram service in Canada 1.888.880.3030
For Monogram Parts and Accessories, call 1.800.626.2002.
CAUTION:
Due to the weight and size of these vent hoods and to
reduce the risk of personal injury or damage to the product,
TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION.
PRUDENCE :
Ă€ cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION
CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create an
electrical safety hazard.
ADVERTISSEMENT :
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse Ă©lectronique externe. Toute modification de ce
type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
ADVERTISSEMENT :
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES
REGLES SUIVANTES:
A. Utiliser cet appareil uniquement de la maniére prévue
par le fabricant. En cas de question, consulter le
fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour Ă©viter la mise sous
tension accidentelle. S’il n’est pas possible de
verrouiller le panneau du disconcteur, attacher un
placard ou une étiquette trés visible au panneau.
•For general ventilating use only. Do not use to exhaust
hazardous or explosive materials or vapors.
•Structural framing, installation work and electrical
wiring must be done by qualified person(s).
In accordance with all applicable codes and
standards including fire-rated construction.
•Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
•Local codes vary. Installation electrical connections and
grounding must comply with applicable codes. In the
absence of local codes, the vent should be installed in
accordance with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
properly exhaust air, be sure to duct air outside – do not
vent exhaust air into spaces within walls or ceilings or into
attics, crawl spaces, or garages.
PRUDENCE : Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque d’incendie
et pouvoir évacuer l’air correctement. Il ne faut pas évacuer
l’air correctement. Il ne faut pas évacuer l’air dans l’espace
entre les parois d’un mur, un plafond ou un grenier,
un espace sanitaire ou un garage.
INSTALLATION OPTIONS
WALL-MOUNTED INSTALLATIONS
This hood may be installed onto a wall and vented to the
outdoors, or it can be installed for recirculating operation.
All necessary parts for a recirculating operation are shipped
with the hood. No kits required.
UNDER-CABINET INSTALLATIONS
The hood may be installed beneath a cabinet. The cabinet must
measure at least 20” from the bottom frame to the inside top.
See page 19.
•Both vented and recirculating operation can be accomplished
in an under-cabinet installation
.
(Custom cabinet modification
is required for recirculating operation.)
Design Information
3
CONTENTS
Design Information
Product Dimensions and Clearances ..................................................3
Installation Options ................................................................................3
Advance Planning, Ductwork, Framing ..............................................4
Power Supply ..........................................................................................4
Duct Fittings..............................................................................................5
Installation Preparation
Tools and Materials Required ..............................................................6
Remove the Packaging ..........................................................................6
Wall Mount Installations ........................................................................7
Installation Below a Wall Cabinet ........................................................7
Check Installation Hardware ................................................................8
Ductwork, Wiring Locations..................................................................9
Wall-Mounted Installation – Vented to the Outside
Step 1, Install Framing for Hood Support............................................9
Step 2, Install Mounting Bracket........................................................10
Step 3, Install Duct Bracket ................................................................10
Step 4, Prepare the Hood ....................................................................11
Step 5, Mount the Hood ......................................................................11
Step 6, Connect Ductwork ..................................................................12
Step 7, Connect Electrical....................................................................12
Step 8, Install Duct Covers ..................................................................13
Step 9, Install Filters..............................................................................13
Step 10, Finalize Installation ................................................................13
Wall-Mounted Installation – Recirculating
Ductwork, Wiring Locations................................................................14
Step 1, Install Framing for Hood Support..........................................14
Step 2, Install Mounting Bracket........................................................15
Step 3, Prepare the Hood ....................................................................15
Step 4, Mount the Hood ......................................................................16
Step 5, Size and Cut Duct Piece ........................................................16
Step 6, Connect Electrical....................................................................17
Step 7, Install Duct Covers ..................................................................17
Step 8, Install Filters..............................................................................18
Step 9, Finalize Installation ..................................................................18
Under-Cabinet Installation
Cabinet Requirements ..........................................................................19
Ductwork, Wiring ..................................................................................19
Step 1, Install Framing for Hood Support..........................................20
Step 2, Prepare the Hood ....................................................................20
Step 3, Cut the Opening........................................................................21
Step 4, Install Side “L” Brackets ........................................................21
Step 5, Remove Side Screw ................................................................21
Step 6, Mount the Hood ......................................................................22
Step 7, Complete Installation and Connect Ductwork....................22
Step 8, Connect Electrical....................................................................23
Step 9, Install Rear Mounting Screws ..............................................23
Step 10, Install Filters............................................................................23
PRODUCT DIMENSION AND
CLEARANCE
The vent hood must be installed 24” min., and 30” max. above
the cooking surface. The telescopic duct cover conceals the
ductwork running from the top of the hood to the ceiling.
The duct cover is sized to reach 8 ft. to 10 ft. ceiling heights.
The hood installation height, from the cooking surface to the
bottom of the hood, depends upon ceiling height.
24” Min.
30” Max.
*24” Min.
* Height to
Ceiling
1-1/2”
12-15/16” at Sides,
13-11/16” at Center
35-7/8”
* The Supplied Duct Cover Fits 8 ft. to 10 ft.
Ceiling Heights
*Depending on Cabinet Height
NOTE: The vent hood
canopy extends
forward 5-7/8”.


Product specificaties

Merk: GE
Categorie: Afzuigkap
Model: ZV800BJBB

Heb je hulp nodig?

Als je hulp nodig hebt met GE ZV800BJBB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap GE

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024