2
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
•
IMPORTANT³ Save these instructions for
local inspector’s use.
•
IMPORTANT³Observe all governing
codes and ordinances.
• Note to Installer³Be sure to leave these
instructions with the Consumer.
• Note to Consumer³ Keep these instructions
with your Owner’s Manual for future reference.
• Completion Time³1 to 3 hours.
• Proper installation is the responsibility of
the installer. Product failure due to improper
installation is not covered under the warranty. See
Owner’s Manual for warranty information.
WARNING
This appliance must be properly grounded.
Follow
directions in ”Electric Supply” of this manual. Failure to do so
may result in electric shock.
For Monogram local service in your area,
1.800.444.1845.
For Monogram Service in Canada, call
1.800.561.3344.
For Monogram Parts and Accessories, call
1.800.626.2002.
If you received a damaged rangetop, you should
contact your dealer.
In the Commonwealth of Massachusetts:
• This product must be installed by a licensed
plumber or gas fitter.
• When using ball type gas shut o valves, they
shall be T-handle type.
• A flexible gas connector, when used, must not
exceed 3 feet.
Vent hood Combinations:
It is recommended that these rangetops be installed
in conjunction with a suitable overhead vent hood.
• Install a hood with at least 1200 CFM above a 48”
wide rangetop.
• Install a hood with at least 600 CFM above a 36”
rangetop.
Due to the high heat capacity of this unit, particular
attention should be paid to the hood and ductwork
installation to assure it meets local building codes.
WARNING:
Do not install this product with an air curtain hood or
other range hood that operates by blowing air down on
the cooktop. This airflow may interfere with operation of
the gas burners resulting in fire or explosion hazard.
Clearances to horizontal surfaces above the range,
measured to the cooking surface are below. Failure to
comply may result in fire hazard.
• Installations without a hood require 48” minimum
to combustibles.
• A custom hood installation with exposed
horizontal combustibles surfaces must have an
Auto-On feature.
• For other installations with a hood, refer to
hood installation instructions for specic hood
clearances.
CAUTION:
These rangetops are extremely heavy. Due to the
weight and size of the rangetop and to reduce the
risk of personal injury or damage to the product:
TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
Installation must conform with local codes. In the
absence of local codes, the rangetop must comply
with the National Fuel Gas Code, ANSIZ223.1/
NFPA 54, latest edition and National Electrical
Code ANSI/NFPA 70 latest addition. In Canada,
installation must conform with the current Natural
Gas Installation Code, CAN/CGA-B149.1 or the current
Propane Installation Code, CAN/CGA-B149.2, and
with local codes where applicable. This rangetop has
been design-certified by CSA International according
to ANSI Z21.1, latest edition and Canadian Gas
Association according to CAN/CGA-1.1 latest edition.
Leak testing of the appliance shall be conducted
according to the manufacturer’s instructions.
If sold outside the U.S. and Canada:
WARNING: If you wish to use this
product with Liqueed Petroleum (LP) gas
containing greater than 10% butane, you must
purchase the butane conversion kit
#WB28K10589. To order, please call
1.888.664.8403 or 1.787.276.4051.
Failure to do so
may result in carbon monoxide or fire hazard.
CONTENTS
Design Information
Models Available ......................................................................3
Backsplash Accessories .......................................................3
Product Dimensions and Clearances
for 48” Wide Models ...............................................................4
Product Dimensions and Clearances
for 36” Wide Models ...............................................................5
Installation Options ...............................................................6
Installation Preparation
Tools and Materials Required ...........................................7
Power Supply Locations .....................................................7
Remove Packaging .................................................................8
Installation Instructions
Step 1, Cut the Countertop Opening ..............................9
Step 2, Install the Rangetop ............................................10
Step 3, Connect Rangetop to Gas ................................10
Step 4, Connect Electrical .................................................11
Step 5, Check Burners .......................................................11
Finalize Installation ..............................................................11
Installation Checklist ...........................................................11
Install the Rangetop Backsplash Accessory............12
Install the Adjustable
Backsplash Accessory ................................................ 13, 14
Gas Conversion ............................................................. 15–17
MODELS AVAILABLE
Monogram rangetops are factory set for natural
gas or LP gas. Order the model for your installation
situation.
48” Natural Gas Models:
ZGU484NG – 4 gas burners, grill and griddle
ZGU486NR – 6 gas burners and grill
ZGU486ND – 6 gas burners and griddle
48” LP Gas Models:
ZGU484LG – 4 gas burners, grill and griddle
ZGU486LR – 6 gas burners and grill
ZGU486LD – 6 gas burners and griddle
36” Natural Gas Models:
ZGU364ND – 4 gas burners and griddle
ZGU364NR – 4 gas burners and grill
ZGU366N – 6 gas burners
36” LP Gas Models:
ZGU364LD – 4 gas burners and griddle
ZGU364LR – 4 gas burners and grill
ZGU366L – 6 gas burners
3
Design Information
30” to 36” Adjustable Height
Backsplash With Shelf
ZXADJB48PSS, for 48” wide rangetops
ZXADJB36PSS, for 36” wide rangetops
12” High Backsplash
ZX12B48PSS, for 48” wide rangetops
ZX12B36PSS, for 36” wide rangetops
BACKSPLASH ACCESSORIES
All models require 12” minimum clearance to a
vertical combustible surface at the rear. If clearance
is less than 12”, the entire surface of the back wall
above the countertop and the full width of the
rangetop must be protected by a backsplash. The
backsplash must be constructed of non-combustible
material, such as metal, ceramic tile, brick, marble
or other stone.
Two Backsplash Accessories Available:
• The 12” high stainless steel backsplash accessory
is available. Use this backsplash in combination
with a custom, non-combustible backsplash built
beyond the 12” height. The combined height of the
backsplash accessory and the custom backsplash
must reach the bottom of a hood, or when there is
no hood, to 48” above the cooking surface.
• An adjustable 30” to 36” high backsplash with
shelf is also available. This backsplash î‹Šlls in the
space between the top of the rangetop and the
bottom of the hood. The shelf is positioned so
that heat lamps from the bottom of a Monogram
professional hood are directed towards the shelf.


Product specificaties

Merk: GE
Categorie: Fornuis
Model: ZGU364LRPSS

Heb je hulp nodig?

Als je hulp nodig hebt met GE ZGU364LRPSS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis GE

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis