GE UPK3 Handleiding

GE Ijsmachine UPK3

Lees hieronder de 📖 handleiding in het Nederlandse voor GE UPK3 (12 pagina's) in de categorie Ijsmachine. Deze handleiding was nuttig voor 8 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
Questions? Call 800.GE.CARES (800.432.2737) or visit our Web site at: GEAppliances.com
Installation Drain Pump
Instructions Kit UPK3
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill you or hurt you and others.
All safety messages will follow the safety alert symbol and the word “DANGER, “WARNING, or “CAUTION. These
words are defined as:
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
DANGER
WARNING
CAUTION
BEFORE YOU BEGIN WHAT YOU WILL NEED:
Read these instructions completely and carefully.
IMPORTANT Save these instructions for
local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer Be sure to leave these
instructions with the Consumer.
Note to Consumer Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires basic
mechanical skills.
Proper installation is the responsibility of installer.
Product failure due to improper installation is not
covered under the Warranty.
3/8” open/box wrench or adjustable wrench
#2 Phillips screwdriver
Slip joint pliers
Side cutting pliers
NOTE: This pump can be installed in a gourmet cube ice
machine or a nugget ice machine.
17-3588-01 31-49092 10-15 GE
5
7
2
3
8
6
10
11
4
1
9
KIT CONTENTS:
1 - Pump and motor with check valve
2 - Switch mounting bracket assembled to
switch assembly
3 - Wire harness
4 - Pressure hose (clear)
5 - Drain hose (white preformed)
6 - Stainless steel shield (for use in cube
models only)
7 - Snap fit clamp
8 - Hose clamp
9 - 2 Screws with lock washers
10- 2 Nuts
11- 2 Washers
REMOVE BACK PANEL
A. Remove all ice if applicable.
B. Drain reservoir by removing reservoir drain
cap. Replace cap when water has drained.
C. Remove the screws from the back panel
(19 for gourmet cube models; 15 for nugget
models).
REMOVE FRONT PANELS
A. Open the ice machine door all the way.
B. Remove the Service Panel.
C. Remove the Kickplate by removing the 2
screws securing it to the base.
REMOVE EXISTING DRAIN HOSE
Remove the existing drain hose. The drain hose
is the white tube with a white snap fit clamp
on it in the upper left hand corner of the side
service panel access area. Save the snap fit
clamp. It will be used to install the new drain
hose.
Installation Instructions
INSTALLING PUMP KIT
1
2
3
4
DISCONNECT ELECTRICAL POWER
Service Panel
Kickplate Screws
(Gourmet Cube
Machine Shown)
Drain Cap - Gourmet Cube Model
Drain Cap - Nugget Model
2
1
Existing Drain Hose
Snap Fit Clamp
2
D. Remove the side service panel. Pull out on the
left side (1) and back (2) to remove.
UCC15
Gourmet
Cube Model
Screw
Locations
UNC15
Nugget Model
Screw
Locations
Electrical Shock Hazard
Death or serious injury can result from failure to
follow these instructions.
Service by a qualified service technician only.
Disconnect power before servicing this product.
Reconnect all grounding devices after service.
Replace all parts and panels before operating.
WARNING
3
Installation Instructions
INSTALL THE PUMP KIT
A. Uncoil the 10-foot long discharge tubing. Push
one end completely onto the barbed discharge
elbow of the pump and securely fasten it with
the small metal hose clamp. Use pliers to open
the hose clamp.
B. Route the other end of the discharge tubing
through the routing panel in the back of the
unit. Put the end of the discharge tube into a
drain.
C. Place the pump over the bolts located on the
base of the ice machine and secure with the
two nuts and washers provided in the kit.
5
Hose
Clamp
Discharge
Elbow
Discharge
Tubing
D. Route the straight portion of drain tube through
the hole in switch assembly bracket.
E. Connect drain tube to pump inlet and secure
with the white snap fit clamp from the kit.
F. Connect the pressure switch hose to the drain
hose.
G. Mount the switch assembly bracket to the base
using two provided sheet metal screws and lock
washers.
H. Trace the black and white power cord from the
switch assembly to the black and white power
cord coming from the unit near the compressor.
Make sure that the wires lay on the left side of
the pump if you are facing the unit from behind.
Unplug the current black and white wire’s
connection. Plug the black and white wire’s
connector from the unit into the black and white
connector from the switch assembly. Repeat
with the red and white connections. It is not
necessary to replace the wire tie that is removed
to disconnect the connector. Connect the 3-pin
connector from the switch assembly bracket to
the 3-pin connector on the pump.
Pump drain
discharge tubing
Bolts Nut & Washer
Pump drain
discharge tubing
Drain tube
Snap fit
clamp
Switch
assembly
bracket
Pump
inlet
Pressure
switch
hose
Drain hose
Switch
assembly
bracket
Sheet metal
screws &
lock washers


Product specificaties

Merk: GE
Categorie: Ijsmachine
Model: UPK3

Heb je hulp nodig?

Als je hulp nodig hebt met GE UPK3 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ijsmachine GE

Handleiding Ijsmachine

Nieuwste handleidingen voor Ijsmachine