GE Profile PD900DPBB Handleiding

GE Fornuis Profile PD900DPBB

Lees hieronder de 📖 handleiding in het Nederlandse voor GE Profile PD900DPBB (24 pagina's) in de categorie Fornuis. Deze handleiding was nuttig voor 23 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
1
31-10829GE10-11
BEFORE YOU BEGIN
Read these in struc tions care ful ly and completely.
IMPORTANT Savetheseinstructionsfor
localinspector’suse.
IMPORTANT Observeallgoverning
codesandordinances.
Note to Installer Besuretoleavethese
instructionswiththeconsumer.
Note to Consumer Keeptheseinstructionsfor
futurereference.
Skill level –Installationofthisappliancerequiresa
qualifiedinstallerorelectrician.
Properinstallationistheresponsibilityoftheinstaller.
ProductfailureduetoimproperinstallationisNOT
coveredunderthewarranty.
30” Electric
Drop-In Ranges
Installation
Instructions
Questions?Call800.GE.CARES(800.432.2737)orVisitourWebsiteat:www.GEAppliances.com.
InCanada,call1.800.561.3344orvisitwww.GEAppliances.ca.
ATTENTION INSTALLER: Allelectricdrop-inrangesmustbehardwired(directwired)intoan
approvedjunctionbox.AplugandreceptacleisNOTpermittedontheseproducts
.
FOR YOUR SAFETY
WARNINGBeforebeginningtheinstallation,switchpoweroffattheservicepanelandlockthe
servicedisconnectingmeanstopreventpowerfrombeingswitchedonaccidentally.Whentheservice
disconnectingmeanscannotbelocked,securelyfastenaprominentwarningdevice,suchasatag,totheservice
panel.
WARNINGTheinformationinthismanualmustbefollowedtominimizetheriskoffire,electricshock,
ortopreventpropertydamage,personalinjuryorlossoflife.
MATERIALS YOU MAY NEED
JunctionBox
WireNuts
StrainReliefClampfor1/2”Conduit
TOOLS YOU MAY NEED
1/8”DrillBitandElectricDrill PhillipsScrewdriver
Level FlatheadScrewdriver
TapeMeasure 1/4”NutDriver
StraightedgeorSquare Hammer
HandorSaberSaw Pencil
SafetyGlasses
A child or adult can tip the range and be killed.
Verify the anti-tip bracket has been properly installed
and engaged.
Ensure the anti-tip bracket is -engaged when the range re
is moved.
Do not operate the range without the anti-tip bracket in
place and engaged.
Failure to follow these instructions can sult in death or re
serious burns children or adults.to
Tip-Over Hazard
WARNING
Oven
Anti-Tip Bracket
Countertop or
Wood Block
Rear
Wall
2
InstallationInstructions
Failuretoremovepackagingmaterialscouldresultindamagetotheappliance.Removeallpackingpartsfrom
oven,racks,andheatingelements.Removeprotectivefilmandlabelsontheouterdoorandcontrolpanel.
Alsoremoveplasticontrimsandpanelandalltapearoundtheoven.Openovendoorandremoveliterature
packandovenracks.Removethebottomtrimfromthesideoftheoven.Itwillbeinstalledattheendofthe
installationprocess.Thetrimiswrappedseparatelyinaplasticbagwhichwillalsocontainthe4screwsto
securethebottomtrimandthe2shoulderscrewsusedtosecuretheproducttothecabinet.
1REMOVE PACKAGING MATERIALS
Allow30”minimumclearance
betweensurfaceunitsandbottom
ofunprotectedwoodormetal
cabinet.Allowa24”minimum
whenbottomofwoodormetalis
protectedbynolessthan1/4”thick
flameretardantmillboardcovered
withnotlessthanNo28MSGsheet
metal(.015”),.015”thickstainless
steel,.024”aluminumor.020”
copper.
NOTE: Drop-In Ranges are designed to hang
from the countertop only. Do not install on a
platform or sup port rails.
2PREPARING THE OPENING (FOR INDOOR USE ONLY)
3
InstallationInstructions
2 PREPARING THE OPENING (Continued)
TheStandardInstallationofthisDrop-InRangeistohang
bythecountertoponthesidemetalflangesunderglass
cooktop.This Range must not be installed on a base or
sub structure (2”x 4” support).
Iftheconstructionofyourcabinetcannotprovidea
1/4”flatareaatthebackofthecountertopopening,
considerchangingthecountertoptoaccommodatethis
dimension.Iftheareaisnotflat,excesstensionmay
beappliedtotheglasscooktop,causingbreakageand
voidingthewarranty.
•Countertopthickness1-1/4”min.isrequiredtosupporttheproduct.Bracesmustbeinstalledbetweenthe
undersideofthecountertopandthecabinetifrequiredtoobtain1-1/4”minimumthickness(eachside).
•Makesurethewallcoverings,countersandcabinetsaroundtheovencanwithstandtheheat(upto200°F
(93.3°C)generatedbytheoven.
•Thisappliancehasbeenapprovedfor0”spacingtoadjacentsurfacesabovethecooktop.However,a6”
minimumspacingtosurfaceslessthan15”abovethecooktopandadjacentcabinetisrecommendedto
reduceexposuretosteam,greasesplatterandheat.
•Locatethewiringjunctionboxattherearofthecutout.Thedimensionfromthetopofthewiringjunction
boxtothecountertopmustbeaminimumof28-1/2”.Theboxmustnotextendmorethan3”offtheplane
ofthewall.Thejunctionboxmustbelocatedwhereitwillallowconsiderableslackintherangeconduit,so
thattherangecanbepulledoutforserviceifnecessary.
Wall
1/4”min.flat
23-3/16”
9/16”min.
flat
9/16”min.
flat
29-15/16”–30-1/16”
smoothcut
25”
typically 1/4”
R
Flat
area
Countertop
Rangesupport


Product specificaties

Merk: GE
Categorie: Fornuis
Model: Profile PD900DPBB

Heb je hulp nodig?

Als je hulp nodig hebt met GE Profile PD900DPBB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Fornuis GE

GE

GE EER3000HKC Handleiding

7 December 2024
GE

GE EER3000LBB Handleiding

7 December 2024
GE

GE EER2000MBB Handleiding

7 December 2024
GE

GE EER2002MBS Handleiding

7 December 2024
GE

GE EER3000HBB Handleiding

7 December 2024
GE

GE EER3000LKC Handleiding

7 December 2024
GE

GE EER3001HSS Handleiding

7 December 2024
GE

GE EER3000LTW Handleiding

7 December 2024
GE

GE EER3000HTW Handleiding

7 December 2024

Handleiding Fornuis

Nieuwste handleidingen voor Fornuis