GE JVX5365SJSS Handleiding

GE Afzuigkap JVX5365SJSS

Lees hieronder de 📖 handleiding in het Nederlandse voor GE JVX5365SJSS (4 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 9 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Installation
Instructions
BEFORE YOU BEGIN
Read these instructions carefully and completely.
IMPORTANT Save these instructions
for local inspector’s use.
IMPORTANT Observe all governing
codes and ordinances.
Note to Installer Be sure to leave these
instructions with the consumer.
Note to Consumer Keep these instructions for
future reference.
Proper installation is the responsibility of the installer
Product failure due to improper installation is not
covered under the Warranty.
Range Hood Connection to
Wall Switch
JVX3240, JVX3300, JVX5305 and JVX5365
TOOLS NEEDED
If you have questions, call GE Appliances at 800.GE.CARES (800.432.2737).
31-11120-1 09-17 GEA
1/4” Nutdriver
Flat blade and Phillips
Head Screwdrivers
FOR YOUR SAFETY
WARNING Before beginning the installation,
switch power o at service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel.
WARNING TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
A Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re-rated construction.
B When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
POWER SUPPLY
IMPORTANT (Please read carefully)
WARNING FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National Electrical Codes or
prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp circuit
breaker or time delay fuse.
Wiring must be 2 wire with ground.
If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
Route house wiring as close to the installation
location as possible in the ceiling or wall.
Connect the wiring to the house wiring in
accordance with local codes.
Grounding instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING The improper connection of the
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or service representative if you are in doubt whether
the appliance is properly grounded.
Wire cutter/stripper
231-11120-1
Installation Instructions
CONNECTION METHOD FOR JVX3240 AND JVX3300
PARTS NEEDED
■ 2-Position and 3-Position wall switches.
■ Electrical wire to connect to wall switch in accordance
with local codes.
■ Wire nuts. Use appropriate wire nuts for size of the
electrical wire.
■ 18 gage white wire.
MOTOR
C30 DX
0
3
BLK
1
ORG
2
VLT
1
GREY
WHT
PINK
ORG
1
VLT
VLT
3
REDRED
OFF
1
WHT
2
WHT
BLK
BLK
BLK
LINE
120Vac
60Hz
HOOD INTERNAL CONTROL
WHT
2
WHT
LAMP
VLT
MOTOR
C30 DX
0
3
BLK
HOOD EXTERNAL CONTROL
ORG
1 2
VLT
1
ORG
1
VLT
RED
OFF
WHT
WHT
BLK
BLK
LINE
120Vac
60Hz
WHT
2
WHT
VLT
LAMP
EXTERNAL
CONTROL
COM S2
G
S1
SPEED2
SPEED1
CONTROL
L
LIGHT
CONTROL
LIGHT
LIGHT
L
WIRING
BOX
GREY
WHT
PINK
WIRING
BOX
312
MOTOR
This connection method allows full control of the range hood using wall switches. However, the rocker switch on the
range hood will be disconnected if this method is used for connection of range hood to wall switch.
Step 1: To establish connection of hood fan to wall
switch, locate the hood junction box and remove its cover.
Step 2: Disconnect the pink wire in the junction box
coming from the motor from the wire coming from red
3-position rocker switch on the range hood. Cap the red
wire coming from 3-position rocker using appropriate
size wire nut.
Step 3: Connect the pink wire in the junction box
coming from the motor to a 3-position wall switch. This
will allow control of high fan speed.
Step 4: Disconnect the grey wire in the junction box
coming from the motor from the wire coming black
from 3-position rocker switch on the range hood. Cap
the black wire coming from 3-position rocker using
appropriate size wire nut.
Step 5: Connect the grey wire in the junction box
coming from the motor to a 3-position wall switch. This
will allow control of low fan speed.
Step 6: Connect a black wire from hot on 3 position wall
switch for fan to the hot wire in the junction box.black
Step 7: Disconnect the orange wire in the junction box
from the wire coming from the motor and cap the white
orange wire using appropriate size wire nut.
Step 8: Connect an 18 gage white wire to the white wire
coming from the motor using appropriate size wire nut
at one end. At the other end connect the 18 gage white
wire to the neutral wire in the junction box using white
appropriate size wire nut.
Step 9: To establish connection of hood lights to wall
switch, connect a wire from hot on 2 position wall black
switch for light to the hot wire in the junction box.black
Step 10: Disconnect the violet wire in the junction box
coming from the lamps from the wire coming violet
from 2 position rocker switch on the range hood. Cap
the violet wire coming from 2 position rocker using
appropriate size wire nut.
Step 11: Connect the violet wire in the junction box
coming from the lamps to the 2 position wall switch.
Step 12: Re-install the junction box cover using the
screws.
Wiring Diagram 991.0438.344
Before getting started, check the wiring diagram number on your hood to make sure
these install instructions apply to your model
31-11120-1 3
Installation Instructions
CONNECTION METHOD FOR JVX5305 AND JVX5365
PARTS NEEDED
■ 2-Position wall switch - Qty (2).
■ Electrical wire to connect to wall switch in accordance
with local codes.
■ Wire nuts. Use appropriate wire nuts for size of the
electrical wire.
■ 18 gage black wire.
0
RED
1b 1a
BLKWHT
M8/35 2V
1
VLT
1
BLK
1
RED
BLK
BLK
TE N
LINE
120Vac 60Hz
2
F
LAMP
VLT
0
(WHT-GRY)
1
WIRING BOX
1 OFF
EXTERNAL
CONTROL
ON-OFF
MOTOR
2
OFF
BLK
VLT
BLK
BLK
BLK
BLK
RED
LAMP
VLT
LAMP
LAMP
1b
G
LINE
120Vac
60Hz
RED
WHT
BLK
RED
WHT
BLK
RED
WHT
BLK
W
HT
BLK
WHT
BLK
BLK
WHT
WHT
ON-OFF
LIGHTING
(WHT-GRY)
(BLU)
WIRING BOX
(BLU)
M8/35 2V
HOOD INTERNAL CONTROL HOOD EXTERNAL CONTROL
1b 1 1a 1b 1 1a 1b 1 1a
This connection method allows switching fan and lights on or o on the range hood using wall switch only. The
rocker switch on the range hood will function and must be kept in on position to allow control of range hood using
wall switch. For fan, the wall switch will turn the fan to speed pre-selected on range hood rocker.
Step 1: To establish connection of hood fan to wall
switch, locate the hood junction box and remove its cover.
Step 2: Remove the access panel in the hood to access
the wiring attached to the range hood rockers.
Step 3: Connect the black wire in the junction box
coming from the fan range hood rocker to 2 position wall
switch.
Step 4: Run power to the 2 position wall switch to
control the fan using wall switch.
Step 5: To establish connection of hood lights to wall
switch, cut the wire coming from the light range black
hood rocker to the middle connector on fan range hood
rocker and cap the end attached to the fan range hood
rocker using appropriate size wire nut.
Step 6: Connect a black 24” min. length 18 gage wire to
the black wire that was cut coming from the light range
hood rocker using appropriate size wire nut. Run the
black wire through the conduit into the junction box to
make sure the wire is not exposed to any sharp edges.
Step 7: Connect the black wire added into the junction
box to 2 position wall switch.
Step 8: Run power to the 2 position wall switch to
control the lights using wall switch.
Step 9: Re-install the access panel and junction box
cover using the screws.
Wiring Diagram 991.0438.625


Product specificaties

Merk: GE
Categorie: Afzuigkap
Model: JVX5365SJSS

Heb je hulp nodig?

Als je hulp nodig hebt met GE JVX5365SJSS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap GE

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024