MICROWAVE/ WALL OVEN COMBINATION
INSTALLATION INSTRUCTIONS
B
B
B
BB
A
A
A
AA
D
D
D
DD
F
F
F
FF
I
I
I
II
H
H
H
HH
G
G
G
GG
11½”
(29.2 cm)
11½”
11½”
11½”
11½”
(29.2 cm)
(29.2 cm)
(29.2 cm)
(29.2 cm)
1¼”
(3.2 cm)
Min.
1¼”
1¼”
1¼”
1¼”
(3.2 cm)
(3.2 cm)
(3.2 cm)
(3.2 cm)
Min.
Min.
Min.
Min.
3” (7.6 cm)
Max.
3” (7.6 cm)
3” (7.6 cm)
3” (7.6 cm)
3” (7.6 cm)
Max.
Max.
Max.
Max.
1” (2.5 cm)
Min.
1” (2.5 cm)
1” (2.5 cm)
1” (2.5 cm)
1” (2.5 cm)
Min.
Min.
Min.
Min.
40-15/16
(104 cm)
40-15/16
40-15/16
40-15/16
40-15/16
(104 cm)
(104 cm)
(104 cm)
(104 cm)
C
C
C
CC
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Your new wall oven has been designed to fit a limited variety of cutout sizes to make the job of installing
easier. The first step of your installation should be to measure your current cutout dimensions and
compare them to the cutout dimensions chart below for your model. You may find little or no cabinet
work is necessary.
P/N 318201521 (0503) Rev. A
English pages 1-6
Español páginas 7-12
All dimensions are stated in inches and (cm).
Do not remove spacers (if equipped) on the side walls and/or on the back of the built-in
oven. These spacers center the oven in the space provided. The oven must be centered to prevent
excess heat buildup that may result in heat damage or fire.
2" (5 cm) Wide Wood
Spacer if Needed
PRODUCT DIMENSIONS
CUTOUT DIMENSIONS AND CABINET WIDTH
Min. F Max. Min. H Max.
MODEL
27" (68.6 cm) Wall Oven
30" (76.2 cm) Wall Oven
MODEL
27" (68.6 cm) Wall Oven
30" (76.2 cm) Wall Oven
A
27 (68.6)
30 (76.2)
B
42¾ (108.6)
42¾ (108.6)
G (Min.)
23½ (59.7)
23½ (59.7)
C
245/8 (62.5)
28¼ (71.8)
D
24½ (62.2)
24½ (62.2)
I
271/8 (68.9) Min
301/8 (76.5) Min
247/8 (63.2)
28½ (72.4)
25¼ (64.1)
29 (73.7)
411/8 (104.5)
411/8 (104.5)
41¼ (104.8)
41¼ (104.8)
NOTES:
1. Base must be capable of supporting 225 pounds (102 kg).
2. Allow at least 21" (53.3 cm) clearance in front of oven for door
depth when it is open.
3. Dimension G (cutout depth) is
critical to the proper installation of
the built-in oven. If the oven
decorative trim does not butt
against the cabinet verify
dimension G to assure it is the
required depth.
Door Open
(see note 2) Spacer Electrical
Junction Box
(right or left side)
Hole for
Cable
(right or
left side
depending
on model)
* Suggested distance from floor
is 11½" (29.2 cm).
Minimum required distance is 4
½" (11.4 cm) Figure 1
Printed in United States
2
MICROWAVE/ WALL OVEN COMBINATION
INSTALLATION INSTRUCTIONS
Important Notes to the Installer
1. Read all instructions contained in these installation
instructions before installing the combination oven.
2. Remove all packing material from the oven
compartments before connecting the electrical supply
to the wall oven.
3. Observe all governing codes and ordinances.
4. Be sure to leave these instructions with the consumer.
5. Oven door may be removed to facilitate installation.
6. THIS COMBINATION OVEN IS NOT APPROVED FOR
STACKABLE OR SIDE-BY-SIDE INSTALLATION.
Important Note to the Consumer
Keep these instructions with your Owner's Guide for future
reference. Do not discard oven removal tools found in the
literature bag.
IMPORTANT SAFETY INSTRUCTIONS
Be sure your combination oven is installed and
grounded properly by a qualified installer or
service technician.
This wall oven must be electrically grounded in
accordance with local codes or, in their absence,
with the National Electrical Code ANSI/NFPA
No.70- latest edition in United Sates, or with CSA
Standard C22.1, Canadian Electrical Code, Part 1, in
Canada.
Stepping, leaning or sitting on the
door of this wall oven can result in serious injuries
and can also cause damage to the wall oven.
Never use your wall oven for warming or heating
the room. Prolonged use of the wall oven without
adequate ventilation can be dangerous.
The electrical power to the oven must
be shut off while line connections are being made.
Failure to do so could result in serious injury or
death.
1. Carpentry
Refer to figure 1 for the dimensions applicable to your
appliance, and the space necessary to receive the
combination oven. The oven support surface may be
solid plywood or similar material, however the surface
must be leveled from side to side and from front to rear.
2. Electrical Requirements
This combination oven must be supplied with the proper
voltage and frequency, and connected to an individual,
properly grounded branch circuit, protected by a circuit
breaker or fuse, having amperage as noted on the rating
plate (the rating plate is located on the side trim).
Observe all governing codes and local ordinances
1. A 3-wire or 4-wire single phase 120/240 or 120/208
Volt, 60 Hz AC only electrical supply is required on
a separate circuit fused on both sides of the line
(time-delay fuse or circuit breaker is recommended).
DO NOT fuse neutral. The fuse size must not exceed
the circuit rating of the appliance specified on the
nameplate.
2. The combination oven can consume up to 5200W
when both ovens are operating. Use a circuit
breaker of 30 Amp with wire gauge #10 AWG.
NOTE: Wire sizes and connections must conform with
the fuse size and rating of the appliance in accordance
with the American National Electrical Code ANSI/NFPA
No. 70-latest edition, or with Canadian CSA Standard
C22.1, Canadian Electrical Code, Part 1, and local codes
and ordinances.
An extension cord should not be used
with this appliance. Such use may result in a fire,
electrical shock, or other personal injury.
3. This combination oven should be connected to the
fused disconnect (or circuit breaker) box through
flexible armored or nonmetallic sheathed cable. The
flexible armored cable extending from the appliance
should be connected directly to the junction box. The
junction box should be located as shown in Figure 1
and with as much slack as possible remaining in the
cable between the box and the appliance, so the
latter can be moved if servicing is ever necessary.
4. A suitable strain relief must be provided to attach
the flexible armored cable to the junction box.
3
MICROWAVE/ WALL OVEN COMBINATION
INSTALLATION INSTRUCTIONS
In cold weather shipping and storage
conditions, make sure that oven is in final location at
least three (3) hours before switching on power.
Switching on power while oven is still cold may damage
the oven controls.
3. Electrical connection
It is the responsibility and obligation of the consumer to
contact a qualified installer to assure that the electrical
installation is adequate and is in conformance with the
National Electrical Code ANSI/NFPA No. 70-latest
edition, or with CSA Standard C22.1, Canadian
Electrical Code, Part 1, and local codes and ordinances.
Electrical ground is required on this appliance.
This appliance is equipped with a copper conductor
flexible cable. If connection is made to aluminum house
wiring, use only special connectors which are approved
for joining copper and aluminum wires in accordance
with National Electrical Code and local codes and
ordinances.
This appliance is manufactured with a white neutral
power supply wire and a frame connected green or bare
copper grounding wire.
Where local codes permit connecting the appliance-
grounding conductor to the neutral (white) wire
(see figure 2):
1. Disconnect the power supply.
2. In the circuit breaker, fuse box or junction box:
connect appliance and power supply cable wires as
shown in Figure 2.
Improper connection of aluminum
house wiring to copper leads can result in a short
circuit or fire. Use only connectors designed for
joining copper to aluminum, and follow the
manufacturer's recommended procedure closely.
You may not ground the oven
through the neutral (white) wire if oven is used in
a new branch circuit installation (1996 NEC), mobile
home, recreational vehicle, or where local codes do
not permit grounding through the neutral (white)
wire. When grounding through the neutral (white)
wire is prohibited, you must use a 4-wire power
supply cable. See Figure 3. Failure to heed this
warning may result in electrocution or other
serious personal injury.
Electrical Shock Hazard
Electrical ground is required on this appliance.
Do not connect to the electrical supply until
appliance is permanently grounded.
Disconnect power to the junction box before
making the electrical connection.
This appliance must be connected to a
grounded, metallic, permanent wiring system,
or a grounding connector should be connected
to the grounding terminal or wire lead on the
appliance.
Do not use a gas supply line for grounding the
appliance.
Failure to do any of the above could result in a
fire, personal injury or electrical shock.
Figure 2
3-WIRE GROUNDED JUNCTION BOX
Cable from Power Supply
Black
Wires
Junction
Box
Cable from appliance
Ground Wire
(Bare or Green Wire)
White Wire
(Neutral)
U.L.-Listed Conduit
Connector (or CSA listed)
Red
Wires
White Wire
(Neutral)


Product specificaties

Merk: Frigidaire
Categorie: Oven
Model: GLEB27M9FB

Heb je hulp nodig?

Als je hulp nodig hebt met Frigidaire GLEB27M9FB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Oven Frigidaire

Handleiding Oven

Nieuwste handleidingen voor Oven

Smeg

Smeg SFP6101VS Handleiding

21 November 2024
Smeg

Smeg SFP6101TVB Handleiding

21 November 2024
Smeg

Smeg SFP6401TVN Handleiding

21 November 2024
Smeg

Smeg SFP6401TVX Handleiding

21 November 2024
Smeg

Smeg SFP6401TVS Handleiding

21 November 2024
Smeg

Smeg SF6101VB Handleiding

21 November 2024
Smeg

Smeg SF6101TVS Handleiding

21 November 2024
Miele

Miele H 2755 B Handleiding

21 November 2024
Smeg

Smeg SF6922BPZE1 Handleiding

21 November 2024
Smeg

Smeg SFC6100VSFR Handleiding

21 November 2024