1 MOUNTING SPACE
This Over the Range Microwave Oven requires a mounting
space on a wall as shown in Figure 1. It is designed to be used
with standard 12" wall cabinets. The maximum depth is 13".
316902446
February 2011
TINSEB294WRRZ-EL01
Printed in Thailand
Backsplash
Figure 1
15.5"
30" or more
from cooking
surface
30"
At least 2"
13” max depth.
BEFORE YOU BEGIN
IMPORTANT Save these instructions for local
inspectors use.
IMPORTANT Observe all governing codes and
coordinates.
NOTE TO INSTALLER – Be sure to leave these
instructions with the Consumer.
NOTE TO CONSUMER Keep these instructions for
future reference.
SKILL LEVEL – Installation of this appliance requires
basic mechanical and electrical skills.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered
under the Warranty.
Please read all instructions thoroughly before installing
the Over the Range Microwave Oven. Two people are
recommended to install this product.
If a new electrical outlet is required, its installation should
be completed by a qualifi ed electrician before the Over the
Range Microwave Oven is installed. See 3 ELECTRICAL
GROUNDING INSTRUCTIONS on page 2.
Read these instructions completely and carefully.
66" or more
from oor
NEED HELP?
For customers in the United States and Canada
United States: 1-800-944-9044
Canada: 1-800-265-8352
READ CAREFULLY. KEEP THESE INSTRUCTIONS.
2 WALL CONSTRUCTION
This Over the Range Microwave Oven should be mounted
against and supported by a at vertical wall. The wall must
be at for proper installation. If the wall is not at, use spacers
to ll in the gaps. Wall construction should be a minimum of
2" x 4" wood studding and 3/8" or more thick dry wall or plaster/lath.
The mounting surfaces must be capable of supporting weight
of 110 pounds—the oven and contents—AND the weight of
all items which would normally be stored in the top cabinet
above the unit.
The unit should be attached to a minimum of one 2" x 4"
wall stud.
To nd the location of the studs, one of the following methods
may be used:
A. Use a stud finder, a magnetic device which locates the
nails in the stud.
B. Use a hammer to tap lightly across the mounting surface
to find a solid sound. This will indicate stud location.
The center of the stud can be located by probing the wall with
a small nail to nd the edges of the stud and then placing a
mark halfway between the edges. The center of any adjacent
studs will normally be 16" or 24" to either side of this mark.
INSTALLATION INSTRUCTIONS
Over The Range Microwave Oven
As a guide to installation, see page 8 for Mounting
Template Information.
E
INSTALLATION INSTRUCTIONS
2
3 ELECTRICAL GROUNDING INSTRUCTIONS
This appliance must be grounded. This oven is equipped with
a cord having a grounding wire with a grounding plug. It must
be plugged into a wall receptacle that is properly installed and
grounded in accordance with the National Electrical Code and
local codes and ordinances. In the event of an electrical short
circuit, grounding reduces risk of electric shock by providing
an escape wire for the electric current.
WARNING - Improper use of the grounding plug can result
in a risk of electric shock.
ELECTRICAL REQUIREMENTS
The oven is equipped with a 3-prong grounding plug. DO
NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE
THE GROUNDING PIN FROM THE PLUG.
DO NOT USE AN EXTENSION CORD. If the power supply
cord is too short, have a qualifi ed electrician or serviceman
install an outlet near the appliance.
The Power Supply Cord and plug must be connected to
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch
circuit, single grounded receptacle. The receptacle should
be located inside the cabinet directly above the Microwave
Oven mounting location as shown in Figure 2.
NOTE:
1. If you have any questions about the grounding or
electrical instructions, consult a qualifi ed electrician or
serviceperson.
2. Neither Electrolux nor the dealer can accept any liability for
damage to the oven or personal injury resulting from failure
to observe the correct electrical connection procedures.
4 HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct
is required. All ductwork must be metal; absolutely do not use
plastic duct. Check that all connections are made securely.
Please read the following carefully:
EXHAUST CONNECTION: The hood exhaust has been designed
to connect to a standard 3 1/4" x 10" rectangular duct. If round
duct is required, a rectangular-to-round adapter must be
used.
REAR EXHAUST: If a rear or horizontal exhaust is to be used,
care should be taken to align the exhaust with the space
between the studs, or wall should be prepared at the time it
is constructed by leaving enough space between wall studs
to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the
total duct length of 3 1/4" x 10" rectangular or 6" diameter round
duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present additional
resistance to air ow and are equivalent to a section of straight
duct which is longer than their actual physical size. When
calculating the total length, add the equivalent lengths of all
transitions and adapters plus the length of all straight duct
sections. Figure 3 shows the approximate feet of equivalent
length of some typical ductwork parts. Use the values in
parentheses for calculating air ow resistance equivalent,
which should total less than 140 feet.
NOTE:
Furnace duct sealing tape is recommended to seal duct
connections to the Exhaust Dampener Assembly.
Opening for
Power Cord
Figure 2
Ground
Receptacle
Figure 3
45° Elbow (5 ft.) Roof cap (24 ft.)
10" Wide Elbow (10 ft.)
Wall cap (40 ft.)
Adaptor (5 ft.)
90° Elbow (10 ft.)
90° Elbow (25 ft.)
45° Elbow (5 ft.)
E
INSTALLATION INSTRUCTIONS
3
5 TOOLS RECOMMENDED FOR
INSTALLATION
Phillips Screwdriver
Electric Drill
1/ ", 25/ " and 83/32" Drill Bits
1 1 / " Wood Bit or Metal Hole Cutter 2
(if metal cabinet is used)
Saw to cut exhaust opening (if needed)
Protective Drop Cloth for product and range -
you may also use carton for protection
Scissors
Pencil
Measure
Tape
6 INSTALLATION HARDWARE
The INSTALLATION HARDWARE items - are in a small
bag. All items are in a bag packed below the oven.
Item Name Quantity
qWood Screw 5 x 35 mm 6
wToggle Bolt 3/ "16 4
eTop Cabinet Screw 5 x 93 mm 2
rFlat Washer 30 mm diameter 2
tGrommet 1
yTapping Screw 4 x 8 mm 4
uExhaust Damper Assembly 1
iGrease Filter 2
oRear Cushion 1
a Installation Instructions 316902446 1
s Top Template 316902447 1
d Wall Template 316902448 1
9
7 PREPARATION OF THE OVEN
1. Open the bottom of the carton, bend the carton flaps
back and tilt the oven over to rest on plastic foam pad.
Lift carton off oven and remove all packing materials,
Installation Instructions, Wall Template, Top Template,
Turntable and Turntable Support; however, DO NOT
REMOVE THE WAVEGUIDE COVER, which is located
on the ceiling in the oven cavity. SAVE THE CARTON AS
IT MAY MAKE INSTALLATION EASIER.
2. CHECK THE OVEN.
Check the oven for any damage, such as misaligned or
bent door, damaged door seals and sealing surfaces,
broken or loose door hinges and latches and dents inside
the cavity or on the door. If there is any damage, do not
operate the oven and contact your dealer or Electrolux
AUTHORIZED SERVICER.
Figure 4
Parts shown not to common scale.
Figure 5
Mounting Plate
Use with metal cabinets. Surround
the power cord opening. Cut to fi t.


Product specificaties

Merk: Frigidaire
Categorie: Magnetron
Model: FGMV205KW

Heb je hulp nodig?

Als je hulp nodig hebt met Frigidaire FGMV205KW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Magnetron Frigidaire

Handleiding Magnetron

Nieuwste handleidingen voor Magnetron