READ BEFORE INSTALLING UNIT
For Through-the-Wall Air Conditioners
Installation Instructions
N
O
TE
:
DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE
Note that the air conditioner dimensions are: 24" wide,14" high, and 19" deep (without front). Install Air Conditioner
according to these installation instructions to achieve the best performance. Save these installation instructions for
future reference.
Do This First (for existing sleeve)
You may not need all parts in the kit. Discard unused parts.
Items in Kit
2020213A1639
Hardware
2
2
3
Tapered Spacer Blocks (17” Long)
Plastic Divider ( )
4
Stuffer Seal ( )
4
1
2
3
4
5 ( )seal
1
6 2
7 3
8
No. Qty.
2
9
Centering/Support Blocks ( )4 x 3 x 1” ”
1
2
1
2
1
2
” ” x 4 x 14
1
8
1
2
1
2
1 x 1 x 84 ” ”
1
2
1 x 1 x 25 ” ”
1
2
seal ( )1 x 1 x 14 ” ”
1
2
seal ( )
1 x x 253/8” ”
seal ( )1 x x 143/8” ”
seal ( )1 x x 143/4” ” 2
Hardware
2
1
1
Ground Wire (green)
2
13
10
11
12
14 Grounding Screw
15 1
16 1
17
No. Qty.
4
18
Trim Frame (top & bottom legs)
Grille (plastic)
Grille Aluminum
Nuts (plastic)
Screw w/washer 4
Trim Frame (side legs)
Toothed washer for grounding screw 2
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may
be exposed:
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils. To
prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit overan extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
Carefully read the installation manual before beginning.
Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
INSTALLATION WARNINGS AND CAUTION
2
Installation Instructions
How to Install
1. Identify the wall-sleeve brand for your installation, from the chart below.
Brand Wall Sleeve Dimensions
Width Height Depth
General Electric/Hotpoint 26 15581578
Sears/Kenmore 253416781858
Carrier (51S Series) 1858
1678
2534
Friedrich* 1634
1634
27
Emerson/Fedders* 15
1534
2634
Whirlpool 2578161217 18or 23
Fedders/Emerson* 27 163416 341934
or
White-Westinghouse 2512151416, 17 or 22
12
Frigidaire 2512151416, 17 or 22
12
Carrier (52F Series) 2512151416, 17 or 22
12
C
A
U
TI
O
N
:
When installation is complete, replacement unit MUST have a rearward slope as shown in Fig.1.
2. Remove old Air Conditioner from wall sleeve and prepare wall sleeve as follows:
Clean interior (do not disturb seals).
Wall sleeve must be securely fastened in wall before installing Air Conditioner. Drive more nails or screws through
sleeve, into wall, if needed.
Retouch wall sleeve painted surface if needed.
Wall
sleeve
REAR
1/4" to 5/16"
FRONT
LEVEL
UNIT
Fig.1
3. If not existing, drill a 3/16" clearance hole for grounding screw through left side of wall sleeve, in a clear area about
3 inches maximum back from front edge of sleeve, using grounding screw and toothed washer. Pull loose end
of ground wire out front of sleeve, and temporarily bend it down and around lower edge of sleeve (Fig.2). This
ground wire will later be attached to frame of air conditioner once it is installed.
Wall sleeve to unit
sleeve grounding
Max.
Hole
Fig.2
IMP
O
RTAN
T
All wall sleeves used to mount the new Air Conditioner must be in sound structural condition and have a rear
grille that securely attaches to sleeve, or rear flange that serves as a stop for the Air Conditioner.
For new installations, a Frigidaire Sleeve Kit (EA108T) is recommended.
For larger sleeves, an adaptor trim kit (EA120T) is available.
3
Installation Instructions
1. Remove the existing grille.
2. Place the grille included with the new air conditioner towards the rear of the sleeve.
3. Mark through the hole positions.
4. Drill through the sleeve flanges with a 1/8" drill bit.
5. Attach the new grille with self-threading screws and washers(not included).
6. It is VERY IMPORTANT that the grille is placed exactly as shown.
7. Most decorative exterior grilles may be left in place as long as the proper interior air direction grille is installed.
FOR INCREASED EFFICIENCY, UTILIZE THE PROVIDED LOUVERED REAR PANEL
4. Prepare the wall sleeve for installation of the new unit per the following Brand instructions.
#1 Emerson
#2 Fedders
#3 Fedders or Friedrich
#4 General Electric/Hotpoint
#5 Sears or Carrier(51S Series)
15 DeepƎ
19 DeepƎ
16 DeepƎ
16 DeepƎ
18 DeepƎ
34
34
78
58
#6 Whirlpool
#7 Whirlpool
#8 White-Westinghouse/Frigidaire/
Carrier(52F Series)
#9 White-Westinghouse/Frigidaire
17 DeepƎ
23 DeepƎ
16 + 17 DeepƎ Ǝ
22 DeepƎ
18
12
MP
RTAN
This unit's increased performance characteristics result from having two rear air intakes.
It is very important that these installation instructions are followed so your unit can operate at maximum
efficiency.
If there is an existing sleeve, and there is an existing rear grille, it needs to be replaced by one that has been
shipped with the unit in the accessory kit.
5. Identify your wall sleeve type and follow the instructions for that type in the following pages.
Installation of new grille provided with unit
NOTE: If the provided grill is not used, it may lead to product damage and possible failure.