Frigidaire FFTA1422R2 Handleiding

Frigidaire Airco FFTA1422R2

Lees hieronder de πŸ“– handleiding in het Nederlandse voor Frigidaire FFTA1422R2 (10 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 25 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
Hardware
2
2
3
Tapered Spacer (17” Long)
4
4
1
2
3
4
5
1
6 2
7 3
8
No. Qty.
2
9
Centering/Support Blocks ( )”4 x 3 x 1 ” ”
1
2
1
2
1
2
Plastic Divider ( )γ€€
1/8 x 4 x 14 ” ” ”
1
2
1
2
Stuffer Seal ( )
1 x 1 x 84” ” ”
1
2
Seal ( )
1 x 1 x 25” ” ”
1
2
Seal ( )
1 x 1 x 14” ” ”
1
2
Seal ( )
1 x 3/8 x 25” ” ”
Seal( )
1 x 3/8 x 14” ” ”
Seal ( )
1 x 3/4 x 14” ” ” 2
Hardware
2
1
1
Ground Wire (green)
2
13
10
11
12
14 Grounding Screw
15 1
16 1
17
No. Qty.
4
18
Trim Frame (top & bottom legs)
Grille (plastic)
Grille Aluminum
Nuts (plastic)
Screw w/washer 4
Trim Frame (side legs)
Tooth washer for grounding screw 2
READ BEFORE INSTALLING UNIT
For Through-the-Wall Air Conditioners
1
Installation Instructions
NOTE:
DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE
Note that the air conditioner dimensions are: 24" wide,14" high, and 19" deep (without front). Install air conditioner
according to these installation instructions to achieve the best performance. Save these installation instructions for
future reference.
Do This First (for existing sleeve)
You may not need all parts in the kit. Discard unused parts.
Items in Kit
16120300A04644
INSTALLATION WARNINGS AND CAUTION
Carefully read the installation manual before beginning. Follow each step as shown.
Observe all local, state, and national electrical codes and by qualified, licensed, authorized personnel only.
Pay attention to danger and safety notices.
To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that
may be exposed.
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and
install the unit. Wear protective gloves whenever lifting or carrying the unit. AVOID the sharp metal fins of front and rear coils.
To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
Carefully inspect location where air conditioner will be installed. Be sure it will support the weight of the unit over an extended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
Common Wall-Sleeve Dimensions
IMPORTANT
All wall sleeves used to mount the new air conditioner must be in sound structural condition and have a rear
grille that securely attached to the sleeve, or rear flange that serves as a stop for the air conditioner.
For new or replacement installations, a Frigidaire Sleeve Kit (EA108T) is recommended.
1. Identify the wall-sleeve brand for your installation, from the chart below.
β€’ Remove old air conditioner from wall sleeve and prepare wall sleeve as follows:
1. Clean interior (do not disturb seals)
2. Check to see that sleeve is securely fastened in wall. Add additional screws or nails as required.
3. Retouch wall sleeve painted surface if needed.
4. If a ground wire or mounting hole does not exist, drill a pilot hole for a grounding screw through the left hand
side of the sleeve. Drill in a clear area about 3 inches back from the front edge a 3/16” pilot hole for the ground
screw. Pull the loose end of the ground wire out of the front of the sleeve and bend it away from the opening.
This will be attached to the air conditioner once installed.
NOTE:
When installation is complete, replacement unit must have rearward slope as shown in Fig 1.
1/4” to 5/16”
Wall Sleeve
Front
Rear
Fig.1 Fig.2
Level
Sleeve
3/16” Pilot Hole
Wall sleeve to unit
Grounding.
3”
Max
1”
GE/Hotpoint/Amana
Friedrich (USC)
Fedders/Emerson/Friedrich (WSE)*
For larger sleeves, an adaptor trim kit (EA120T) is available.
16”, 17 ½”, or 22”
16”, 17 ½”, or 22”
16”, 17 ½”, or 22”
16 ”
78
17 ” or 23”
18
18
”
58
18
”
58
16
”
34
25 ”
78
15 ”
12
16 ”
78
16 ”
78
15 ”
58
25 ”
78
2
Installation Instructions
Existing Frigidaire sleeves may have older single sided intake grilles
New Dual Intake Grille
IMPORTANT
This units increased performance characteristics is the result of having two rear intakes.
If there is an existing sleeve and rear grille, it should be replaced with the one shipped with the unit in the
accessory kit.
It is very important that these installation instructions are followed so your unit can operate at maximum efficiency.
1. Remove the existing grille and save the mounting
screws.
2. Place the grille included with your new air conditioner
towards the inside rear of the sleeve.
3. Attach the new grille by aligning the four mounting
holes.
4. Re-insert the self-tapping screws into the nylon
retainers.
β€’ These grilles should be replaced with the dual intake grille supplied with the air conditioner.
Left Intake Grille
Left Intake
Right Intake Grille
Right Intake
3
Installation Instructions


Product specificaties

Merk: Frigidaire
Categorie: Airco
Model: FFTA1422R2

Heb je hulp nodig?

Als je hulp nodig hebt met Frigidaire FFTA1422R2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Frigidaire

Handleiding Airco

Nieuwste handleidingen voor Airco