Frigidaire FAD504TDDW Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Frigidaire FAD504TDDW (10 pagina's) in de categorie Ontvochtiger. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
TA B L E O F C O N T E N T S
www.frigidaire.com USA 1-800-944-9044 www.frigidaire.ca Canada 1-800-265-8352
All about the
Use&Care
of your Dehumidifier
2020266A0107 (June 2009)
Location
.......................................................
2
How It Works 2
..............................................................
Important Safety Instructions ............................... 2 Care And Cleaning .............................................. 8
Storage .............................................................
Before You Call ................................................... 9
Major Appliance Warranty ................................... 10
8
3-7Operating Instructions ..........................................
Important Safety Instructions, Location & How It Works
22009 Electrolux Home Products, Inc. All rights reserved.
WARNING
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance. Read product labels for flammability and other warnings.
Discard water from bucket. Water is not potable and cannot be used for drinking.
WARNING
Child Safety Precautions
Destroy the carton, plastic bags, and any packing materials immediately after the
dehumidifier is unpacked. Children should never use these items for play.
Do not leave children unattended in an area where the appliance is operating.
Do not allow them to sit or stand on the appliance.
Power supply cord
with 3-prong grounding
plug
Grounding type wall
receptacle
Do not, under any
circumstances, cut,
remove, or bypass the
grounding prong.
WARNING
Avoid fire hazard or electric shock. Do not
use an extension cord or an adaptor plug. Do
not remove any prong from the power cord.
For your safety and protection, this dehumidifier is equipped with a three-prong grounding
plug on the power cord. Do not, under any circumstances, cut or remove the round ground
prong from the plug.
Your dehumidifier must be plugged directly into a properly grounded and polarized
three-prong receptacle. lf the wall receptacle you intend to use will not accept a
three-prong plug, or if you are not sure the outlet is adequately grounded or protected
by a time delay fuse or circuit breaker, have a qualified electrician install the proper outlet
according to the National Electrical Code and applicable local codes and ordinances. Do not
use an extension cord or an adapter plug.
Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly
and pull straight out from the receptacle.
WARNING
Electrical Information
Do not pinch, bend, or knot the power cord.
NOTE:
This USE & CARE MANUAL provides specific operating instructions for your model. Use the room air conditioner only as instructed in this USE &
CARE MANUAL. These instructions are not meant to cover every possible condition and situation that may occur. Common sense and caution
must be practiced when installing, operating, and maintaining any appliance.
The coils condense or draw moisture from the air, and air flows through the side louvers into the
room as dry, warm air. Moisture removed from air is collected in a bucket on the front of the
dehumidifier.
4. The dehumidifier must be installed on a level floor that will support it with a full bucket of
water.
5. There should be a minimum of 12 inches clearance around the dehumidifier.
2. Place dehumidifier in a location that does not restrict airflow through the front of the unit or
out of the louvers on the left side of cabinet.
3. A dehumidifier operating in a basement will have little or no effect in drying an adjacent
enclosed storage area, such as a closet, unless there is adequate circulation of air in and out
of the area. lt may be necessary to install a second dehumidifier in the enclosed area for
satisfactory drying.
1. Dehumidifier must be operated in an enclosed area to be most effective. Close all doors,
windows, and other outside openings to the room. The effectiveness of the dehumidifier
depends on the rate at which new moisture-laden air enters the room.
Location Selecting a Location
IMPORTANT:
How It Works When the unit is started, the fan begins to pull moisture-laden air across the dehumidifying coils.
The unit is designed to operate between 41 °F (5 °C), and 96 °F(35 °C).
The "Compressor" circuit has an automatic 3 minute time delayed start if the unit is turned off
and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.
Make sure the tank is fitted correctly otherwise unit will not turn on.
Operating Instructions
Operating Instructions
3
2009 Electrolux Home Products, Inc. All rights reserved.
Allow the unit to reach room temperature before operating.
To begin operating the dehumidifier, follow these steps:
1. Plug the power cord into a properly grounded 115 volt AC outlet. The POWER indicators will illuminate.
If the "BUCKET FULL" light is on, remove the bucket and re-install to reset the float switch.
NOTE:
Unit must be upright for one hour prior to operating.
NOTE:
2. To turn the unit on press the ON/OFF button. The unit will run in the factory setting of CONTINUOUS and high fan speed.
In the Continuos Mode the unit will only display CO and not the room humidity. It is recommended you leave the unit
running in the CONTINUOUS setting for the first three or four days until the sweating and dampness odors have stopped.


Product specificaties

Merk: Frigidaire
Categorie: Ontvochtiger
Model: FAD504TDDW

Heb je hulp nodig?

Als je hulp nodig hebt met Frigidaire FAD504TDDW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ontvochtiger Frigidaire

Handleiding Ontvochtiger

Nieuwste handleidingen voor Ontvochtiger