CHRONOTHERMOSTAT (PROGRAMMABLE THERMOSTAT) OVERVIEW
1
2
3
10
9
8
4 5 6 7
14 15 16 17 11 20 12 13 18 1921
22
23
CHRONOTHERMOSTAT CONFIGURATION AND ACTIVATION IN 4 EASY STEPS
Step 1. Installing the batteries
Note: Follow the instructions in this section only if the Chronothermostat display activates the symbol or if
the display is off (symbols or numbers do not appear). Otherwise go straight to Step 2 : Correct setting of time
and day.
To install the batteries:
1. With the Chronothermostat xed to the wall: to access the batteries remove the front by prising with a screwdriver
at points A and B, as shown in the fi gure.
2. Insert the two AA LR6 type 1.5 V alkaline batteries supplied with the Chronothermostat, making sure to t them
in the right direction (as shown on the inside of the front).
3. Refi t the front part of the Chronothermostat. (Make sure to centre the front on the rear part to ensure correct
insertion of the contacts)
Step 2. Correct setting of time and day
1. Press the button
DAY
. The day indication starts fl ashing: press the buttons to set the correct day,
considering that DAY 1 is Monday and DAY 7 is Sunday.
2. Press the button
DAY
. The hour indication starts fl ashing: press the buttons to set the correct hour
from 00 to 23.
3. Press the button
DAY
. The minutes indication starts ashing: press the buttons to set the correct
minutes from 00 to 59.
4. Press the button
DAY
.
Step 3. Setting the weekly automatic programme
After setting the time and day, the chronothermostat will carry out the preset automatic programme.
The heating programme provides for 6 daily temperature time bands, numbered 1 to 6. The bands can be set between
00:00h and 24:00h, adjusting them by increments of 10 minutes. Each temperature level can be set between 7°C
and 32.5°C, adjusting it by increments of 0.1°C. Any combination of time and temperature during the day can be
programmed, and each day of the week can be different from the others.
The preset automatic programme is as follows:
Carry out the following instructions to modify the preset automatic programme.
1. Press the button . The 6 daily time bands fl ash and the number 1 of DAY 1 in a box indicates that the time
band 1 of Monday can be modifi ed.
2. Press the button . The hour and minutes indication starts fl ashing: press the buttons to modify the
time band start hour by increments of 10 minutes. Keep the button pressed and the hours and minutes will
change quickly.
3. Press the button . The indication of room temperature inside the home starts ashing: press the buttons
to modify the temperature level by increments of 0.1°C. Keep the button pressed and the temperature
will change quickly.
4. Press the button . The 6 daily time bands fl ash.
5. Then press the button to display time band 2 of Monday, which can be modifi ed by repeating points 2 to
4.
6. The other time bands can be displayed by selecting bands 3, 4, 5 or 6 with the buttons , repeating
point 5.
7. The programme setting for the next day can now be selected:
a. Press the button
DAY
to display DAY 2. The programme for Tuesday can be modifi ed by repeating points
2 to 6.
b. Press the button to copy Monday's programme in Tuesday. To copy the same programme even on the
next days of the week, press the button repeatedly.
A
B
Important! Set the programme, making sure that each band has a different start time.
Step 4. Operation mode selection
Heating automatic mode
Press the button , displaying the symbol . The chronothermostat will work according to the weekly
automatic programme, displaying the 6 time bands: the one in a box will be active at that moment. If the display
does not show the box, it means that the current time is between 00:00h and the start of time band 1.
Exclusion of set temperature level
During automatic mode, press the
buttons
to temporarily change the room temperature value by
increments of 0.1°C. Keep the button pressed and the temperature will change quickly. The exclusion function,
indicated on the display by fl ashing of the symbol , will be cancelled at the fi rst change of time band.
Heating manual mode
To use the chronothermostat with a xed room temperature level press the button , displaying the
symbol (the 6 time bands are not displayed). Then press the
buttons
to set the room temperature
value, by increments of 0.1°C. Keep the button pressed and the temperature will change quickly. Manual
mode will be maintained until another operation mode is selected.
Turning off heating
In case of a prolonged absence from the home (also see Vacation Function) or simply to turn the heating off,
press the button , displaying the symbol (the symbol is not displayed). Heating is turned off, and
activated only if the room temperature falls below 5°C: function for protection against freezing in the home.
To reactivate heating and return to the previously set operation mode, press the button again.
SPECIAL FUNCTIONS
Vacation Function
This function turns the heating off for a fi xed period of time, from 1 hour to 45 days, adjusting it by increments of
1 hour. This offers savings in energy and related costs when away from home, whereas the previously set operation
mode resumes when the Vacation function ends. Heating is activated only if the room temperature falls below 5°C:
function for protection against freezing in the home.
Carry out the following instructions to activate and set the Vacation function.
1. Press the button . The symbol starts fl ashing and the hour and minutes indication becomes –00:01,
which is the time remaining until the end of the Vacation function.
2. Press the buttons to prolong the time remaining until the end of the Vacation function, by increments
of 1 hour (-00:01 means 1 hour; -45:00 means 45 days). Keep the button pressed and the time and days will
change quickly.
3. During the Vacation function, the display will continue to indicate the time remaining until the function ends.
To cancel the Vacation function, press the button or any other button associated with a different operation
mode.
Party Function
This function adjusts the heating to a room temperature level, which can be set between 7°C and 32.5°C, adjusting
it by increments of 0.1°C, for a xed time period of 1 hour to 24 hours, adjusted by increments of 1 hour. This is
useful especially for maintaining or increasing the temperature during a special occasion, such as a party or when
there are guests. The function can also be used to lower the temperature when away from the home for a short time
(e.g. for shopping, visiting friends, etc.), saving energy and money; the previously set operation mode resumes
when the Party function ends.
Carry out the following instructions to activate and set the Party function.
1. Press the button . The symbol starts ashing and the hour and minutes indication becomes –01:00,
which is the time remaining until the Party function ends.
Press the buttons to modify the temperature level by increments of 0.1°C. Keep th e
button pressed and the temperature will change quickly.
3. Press the button
DAY
to prolong the time remaining until the end of the Party function by increments of 1
hour (-01:00 means 1 hour; -24:00 means 24 hours).
4. During the Party function, the display will continue to indicate the time remaining until the functions ends.
To cancel the Party function, press the button or any other button associated with a different operation
mode.
Holiday Function
This function temporarily carries out the Sunday heating automatic programme, for the current day or the next day.
It is useful when there is a holiday during the week or when staying home on a work day in case of sickness, etc.;
the previously set operation mode resumes when the Holiday function ends.
Carry out the following instructions to activate and set the Holiday function.
1. Press the button . The symbol starts fl ashing together with the current day of the week and the DAY
symbol, indicating that heating will be controlled according to the Sunday heating automatic programme until
23:59 on the current day.
2. Press the button again. The symbol ashes together with the next day of the week and the DAY symbol,
indicating that heating will be controlled according to the Sunday heating automatic programme from 00:00h
until 23:59h on the next day.
To cancel the Holiday function, press the button or any other button associated with a different operation
mode.
1 Heating On/Off button
2 Heating automatic/manual mode button
3 Heating programming button
4 Time and day setting button
5 Party function button
6 Holiday function button
7 Information/user settings button
8 Vacation function/copy heating programme day
button
9 Manual room temperature decrease button
10 Manual room temperature increase button
11 Heating programme time bands
12 Day of the week indication
13 Hours and minutes indication
14 Heating turning off indication
15 Heating manual mode indication
16 Heating automatic mode indication
17 Vacation function indication
18 Boiler lighting request indication
19 Batteries low indication
20 Room temperature indication
21 Heating mode indication
22 Room antifreeze operation indication
23 Fault indication
From Monday to Friday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time 06:30 08:00 12:00 14:00 18:00 22:30
Temperature level 21°C 18°C 21°C 18°C 21°C 16°C
From Saturday to Sunday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time 08:00 10:00 12:00 14:00 18:00 22:30
Temperature level 21°C 21°C 21°C 21°C 21°C 16°C
Personal programme note
Monday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Tuesday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Wednesday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Thursday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Friday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Saturday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
Sunday Band 1 Band 2 Band 3 Band 4 Band 5 Band 6
Start time
Temperature level
If the batteries are not com-
pletely at, the chronother-
mostat will activate all the
symbols of the display.
EN
USER PARAMETER EDITING
Duration of On/Off cycle
When the room temperature tends to approach the programmed room temperature, the Chronothermostat starts
controlling, activating and deactivating heating in a cyclic way. The sum of activation and deactivation times is
constant within a cycle. If the activation time increases, that of deactivation decreases and vice versa, propor-
tionally. Cycle duration can be modifi ed from 5 to 60 minutes, adjusting it by increments of 1 minute.
1. Press the button for 3 seconds
2. The display shows parameter P1
Press the buttons to modify the cycle duration by increments of 1 minute. Keep the button
pressed and the time will change quickly.
3. Press any other button to exit the menu.
Control of Heating/Cooling
Carry out the following instructions to use the Chronothermostat for controlling heating or cooling.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button .
4. The display shows parameter P2.
Set to 0 using the buttons to control heating.
Set to 1 using the buttons to control cooling.
5. Press any other button to exit the menu.
Pump antiblocking function
When the function is enabled, the Chronothermostat relay is powered for 5 seconds near 12:00h every day,
if it was not activated in the previous 24 hours.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button twice.
4. The display shows parameter P3.
Set to 0 using the buttons to deactivate pump antiblocking. Set to 1 using the buttons
to activate pump antiblocking.
5. Press any other button to exit the menu.
Pre-heating function
The function is active only if heating automatic mode was selected.
When set to Automatic, the function anticipates the heating system start time (not before 00:00h on the same day)
so that the room temperature set by the user is reached at the start of the programmed band. The Chronothermostat
calculates a rst hypothetical Pre-activation time: if the programmed room temperature is reached sooner than the
calculated time, the Pre-heating time is decreased and vice versa. In this way a self-learning process is created to
determine the shortest necessary pre-heating time.
The Chronothermostat also offers the possibility of setting a fi xed Pre-heating slope: in this case, the room tempe-
rature will be increased by 3°C an hour.
Therefore the heating automatic programme must be programmed according to the time heating is required, and
not that of starting of the heating system.
Carry out the following instructions to activate or deactivate the function.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button 3 times.
4. The display shows parameter P4.
Set to 0 using the
buttons
to deactivate Pre-heating. Set to 1 using the
buttons
to activate
Automatic Pre-heating. Set to 2 using the
buttons
to activate Pre-preheating with a xed slope
of 3°C an hour.
5. Press any other button to exit the menu.
During the pre-heating function the room temperature °C symbol fl ashes.
The pre-heating function ends when the difference between the programmed room temperature and the actual
temperature is less than 0.5 °C.
Maximum number of daily time bands
The heating programme provides for 6 daily temperature level time bands numbered 1 to 6. If necessary
they can be reduced to a minimum of 2.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button 4 times.
4. The display shows parameter P5.
Press the buttons to modify the number of daily time bands between 2 and 6.
5. Press any other button to exit the menu.
Temperature measurement unit selection
Carry out the following instructions to use the Chronothermostat in °C or in °F.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button 5 times.
4. The display shows parameter P6.
Set to 0 using the buttons to select °C.
Set to 1 using the buttons to select °F.
5. Press any other button to exit the menu.
Correction of room temperature reading
Carry out the following instructions to correct the room temperature reading between –2°C and + 2°C by steps
of 0.1°C.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button 6 times
4. The display shows parameter P7.
Use the buttons to adjust the parameter by increments of 0.1°C.
5. Press any other button to exit the menu.
Telephone contact input
Normal Chronothermostat operation is guaranteed as long as the telephone contact remains open. Closing of this
contact, indicated on the display with the symbols (), can be used to force the Chronothermostat to turn off the
heating or to adjust the room temperature to a preset fi xed value.
Carry out the following instructions to set the two functions.
1. Press the button for 3 seconds
2. The display shows parameter P1
3. Press the button 7 times
4. The display shows parameter P8.
Set to 0 using the buttons to turn off heating on closing of the contact. Set to 1 using the buttons
to adjust the room temperature to a preset xed value (through the next parameter P9) on closing of
the contact.
5. Press the button .
6. The display shows parameter P9.
Set the room temperature value that the Chronothermostat will adjust on closing of the contact (if parameter
P8 was set to 1), pressing the buttons by increments of 0.1°C. Keep the button pressed and the
temperature will change quickly.
7. Press any other button to exit the menu.
Modifi cation of Chronothermostat operation mode on opening or closing of the telephone contact can occur with a
maximum time of 60 seconds.
OTHER FUNCTIONS
Chronothermostat information
1. Press the button .
2. The display shows parameter t1 which indicates the activation time (in minutes) inside the On/Off cycle calculated
by the Chronothermostat.
3. Press the button .
4. The display shows the parameter v which indicates the Chronothermostat software version.
5. Press any other button to exit the menu.
Room temperature probe fault
In case of a Chronothermostat room temperature probe fault, the display activates fault E92 and the symbol
. Heating is turned off.
Restoring factory settings
Important! With this procedure all the Chronothermostat parameters will be restored to the factory-set value,
except for the time and day setting. Therefore it will be necessary to repeat the procedure for the weekly automatic
programme and reset the user parameters.
Press the buttons together for 10 seconds: only the message RE ashing is displayed. The procedure is
interrupted on releasing the buttons at any time before the 10 seconds are up. Whereas once reset, the chronother-
mostat activates all the symbols on the display.
INSTALLATION
The Chronothermostat must be xed to the wall
at a height of approx. 1.5 m from the oor, in a
place away from doors, windows or heat sources
that can affect the room temperature. Disconnect
the power to the boiler before carrying out instal-
lation. Remove the front of the Chronothermostat
by prising with a screwdriver at points A and B.
Then fi x the back of the Chronothermostat to the
wall with the set of screws supplied, making sure
to pass the 2 wires inside the middle hole: remove
the cover protecting the relay contact and make
the electrical connection. If necessary, connect
the telephone contact (voltage-free contact) using
the terminals on the back of Chronothermostat
near the batteries.
Refi t the front of the Chronothermostat.
TECHNICAL CHARACTERISTICS AND DEFAULT SETTINGS
Setting the time 12:00
Setting the day Day 1=Monday
Operation mode Automatic
Heating manual temperature 20°C
Room antifreeze temperature 5°C
P1 Duration of On/Off cycle 20 minutes
P2 Heating/Cooling control 0=Heating
P3 Pump antiblocking function 0=Deactivated
P4 Pre-heating function 0=Deactivated
P5 Maximum number of daily time bands 6
P6 Temperature measurement unit selection 0=°C
P7 Correction of room temperature reading 0
P8 Telephone contact input operation selection 0=Turning off heating
P9 Manual temperature on closing of telephone contact input 20°C
Relay contacts rating 24... 230 Vac 5A resistive load
Wiring Terminal block for receiving
wires of up to 2.5 mm
Guaranteed average battery life 1 year
A
B


Product specificaties

Merk: Ferroli
Categorie: Niet gecategoriseerd
Model: Oscar W

Heb je hulp nodig?

Als je hulp nodig hebt met Ferroli Oscar W stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Ferroli

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd