User's Guide
Multimeter with IR Thermometer
Extech EX230
EX230-en-GB_1.4 4/15 2
Introduction
Congratulations on your purchase of the Extech EX230 Autoranging Multimeter. This meter measures
AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, Duty Cycle, Diode Test, and
Continuity plus non-contact InfraRed Temperature and contact thermocouple Temperature. Proper use
and care of this meter will provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds (in this case) 600 VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in which
measures are taken to limit the transient overvoltages to an appropriate low level.
Note β Examples include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be supplied from
the fixed installation.
Note β Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note β Examples include switches in the fixed installation and some equipment for industrial use
with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
Note β Examples include electricity meters and primary over-current protection equipment
WARNING
CAUTION
MAX
600V
EX230-en-GB_1.4 4/15 3
CAUTIONS
ξ Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
ξ Always remove the test leads before replacing the battery or fuses.
ξ Inspect the condition of the test leads and the meter itself for any damage before operating the
meter.
ξ Use great care when making measurements if the voltages are greater than 25 VAC rms or 35
VDC. These voltages are considered a shock hazard.
ξ
Warning! This is a Class A device. This dev
ice can cause interference in residential areas.
ξ
Always discharge capacitors and remove power
from the device under test before performing
Diode, Resistance or Continuity tests.
ξ
Voltage checks on electrical outlets can be di
fficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
ξ If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
ξ
This device must not be used by children. It contains hazardous objects
as well as small parts
that the children could swallow.
ξ
Do not leave batteries and packing material
lying around unattended; they can be dangerous
to children.
ξ
In the event that this device will be stored fo
r an extended period of time, remove the batteries.
ξ Expired or damaged batteries can be hazardous to skin. Use suitable hand gloves in such
cases.
ξ Do not short-circuit the battery. Do not place the battery near a fire.
Product specificaties
Merk: | Extech |
Categorie: | Multimeter |
Model: | EX230 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extech EX230 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Extech
27 November 2023
27 November 2023
27 November 2023
27 November 2023
10 Juni 2023
10 Juni 2023
10 Juni 2023
10 Juni 2023
7 Juni 2023
7 Juni 2023
Handleiding Multimeter
- Multimeter Abus
- Multimeter Aldi
- Multimeter Alecto
- Multimeter Altai
- Multimeter Amiko
- Multimeter Amprobe
- Multimeter Appa
- Multimeter Basetech
- Multimeter Beha-Amprobe
- Multimeter Benning
- Multimeter Brandson
- Multimeter Brennenstuhl
- Multimeter Bruder Mannesmann
- Multimeter Digitus
- Multimeter Elma
- Multimeter Elro
- Multimeter Ferm
- Multimeter Flir
- Multimeter Fluke
- Multimeter Gembird
- Multimeter Gossen Metrawatt
- Multimeter Greenlee
- Multimeter Hager
- Multimeter Hubinont
- Multimeter Ideal
- Multimeter Keithley
- Multimeter Kingcraft
- Multimeter Laserliner
- Multimeter Mastech
- Multimeter Maxwell
- Multimeter Megger
- Multimeter Metrel
- Multimeter Metrix
- Multimeter Micronta
- Multimeter Milwaukee
- Multimeter Monacor
- Multimeter Parkside
- Multimeter PCE Instruments
- Multimeter Perel
- Multimeter Plieger
- Multimeter Powerfix
- Multimeter Profile
- Multimeter Sanwa
- Multimeter Schneider
- Multimeter Silverline
- Multimeter Skandia
- Multimeter Stanley
- Multimeter TFA
- Multimeter Topcraft
- Multimeter Uni-T
- Multimeter Velleman
- Multimeter Voltcraft
- Multimeter Wiha
- Multimeter Workzone
- Multimeter Joy-it
- Multimeter Jung
- Multimeter Clas Ohlson
- Multimeter Steren
- Multimeter Klein Tools
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Biltema
- Multimeter REV
- Multimeter Etekcity
- Multimeter Testo
- Multimeter Somogyi
- Multimeter Testboy
- Multimeter Yato
- Multimeter Wago
- Multimeter GW Instek
- Multimeter Kyoritsu
- Multimeter Owon
- Multimeter Projecta
- Multimeter Cablexpert
- Multimeter HΓΆgert
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Kewtech
- Multimeter Sonel
- Multimeter Testec
- Multimeter Vimar
- Multimeter Strex
- Multimeter PeakTech
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Rigol
- Multimeter Chauvin Arnoux
- Multimeter Aim TTi
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Kurth Electronic
- Multimeter Weltron
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter WeidmΓΌller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nieuwste handleidingen voor Multimeter
17 November 2024
14 November 2024
11 November 2024
22 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
30 September 2024