Etna 4421 RVS Handleiding

Etna Afzuigkap 4421 RVS

Lees hieronder de 📖 handleiding in het Nederlandse voor Etna 4421 RVS (18 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 32 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/18
3LI0C2.2
COOKER HOOD
USER INSTRUCTIONS
DUNSTABZUGSHAUBE
GEBRAUCHSANWEISUNG
HOTTE PER CUISINE
MANUEL DUTILISATION
GEBRUIKSAANWIJZING
AFZUIGKAP
MANUAL DE UTILIZACIÓN
CAMPANA EXTRACTORA
MANUAL DO USUÁRIO
CAPPA ASPIRANTE
MANUALE DUSO
VENTILATOR
BRUKERVEILEDNING
BRUGERVEJLEDNING
LIESITUULETIN
ODHGIES CRHSEWS
OKAP
INSTRUKCJE UZYTKOWNIKA
ODSAVAC
NÁVOD K POÙZITÌ
PARAELSZIVÓ
HASZNÁLATI ÚTMUTATÓ
GB
D
F
NL
E
I
P
S
N
GR
RUS
PL
CZ
H
FIN
DK
COIFA ASPIRANTE
- 3 -
587 490
102
824 : 1279
F
E
Fig.1
Fig.2
GBCDEA
1A
1B
Fig.5Fig.5
ABCDEF
Z
E
F
G
Y
Fig.3
B
C
3
13
352
203
460
65
D
20
A
235
253
Z
A
D
C
B
493
Fig.4
- 4 -
GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed as a exhausting version (external
exhaust) or as a filter version (internal air recycle) cooker hood.
SAFETY PRECAUTION
• Take care when the cooker hood is operating simultaneously
with an open fireplace or burner that depend on the air in the
environment and are supplied by other than electrical energy, as
the cooker hood removes the air from the environment which a
burner or fireplace need for combustion.
The negative pressure in the environment must not exceed 4 Pa (4
x 10 –5 bar).
Provide adequate ventilation in the environment for a safe operation
of the cooker hood.
Follow the local laws applicable for external air evacuation.
•WARNING!!
In certain circumstances electrical appliances may be a danger
hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch the light bulbs after appliance use
C) Flambè cooking is prohibited underneath the cooker hood
D) Avoid free flame, as it is damaging for the filters and a
fire hazard
E) Constantly check food frying to avoid that the overheated
oil may become a fire hazard
F) Disconnect the electrical plug prior to any maintenance.
INSTALLATION INSTRUCTIONS
The appliance has been manufactured as a class II, therefore no
earth cable is necessary.
The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral
If not provided, connect a plug for the electrical load indicated on
the description label. Where a plug is provided, the cooker hood
must be installed in order that the plug is easily accessible.
An omnipolar switch with a minimum aperture of 3mm between
contacts, in line with the electrical load and local standards, must
be placed between the appliance and the network in the case of
direct connection to the electrical network.
• The appliance must be installed at a minimum height of 650 mm
from an cooker stove.
If a connection tube composed of two parts is used, the upper part
must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conductor
used to circulate hot air or for evacuating fumes from other
appliances generated by other than an electrical source.
• Mounting the cooker hood to the wall
Drill holes A-B-C-D according to indications quoted in (fig. 3).
Use screws and screw anchors suitable for wall (e.g. reinforced
cement, plasterboard) for the mounting of the cooker hood.
Where screws and screw anchors are supplied ensure that they
are suitable for the type of wall where the cooker hood is to be
mounted.
Lock in the flange connector Y to the cooker hood (fig. 2).
Affix the bracket Z to the wall via the drill holes A (fig. 4).
Hang the cooker hood on the wall using the drill holes C (fig. 3).
Fasten the cooker hood using the fastening drill holes D (fig. 3).
• Exhausting Version
Connect the flange Y to the discharge opening with a connecting
tube (do not carry out for filter version).
Thread the upper connector E to the inside of the lower connector
F; hang the two connectors inserting them vertically on the cooker
hood locking the lower connector F to the wall using the drill holes
B (fig. 3), unthread the upper connector E towards the top, locking
it in with the appropriate screws in the drill holes G of the bracket
Z (fig. 2) previously affixed to the wall via the drill holes A (fig. 3).
In order to transform your cooker hood from exhausting version to
filter version, ask your local retailer for active carbon filters and
then carry out instructions for mounting filter version cooker hood.
•Filter Version
Install the cooker hood and the two connectors as described in the
paragraph mounting the exhausting version cooker hood.
To mount the filter connector refer to instructions included in the
kit.
If the kit is not supplied, then order the kit as an accessory from
your local dealer.
The filters must be fitted to the fan unit placed inside the cooker
hood. The air is replaced in the environment via the eyelets
impressed on the connector E.
USE AND MAINTENANCE
• It is recommended to operate the appliance prior to cooking.
It is recommended to leave the appliance in operation for 15 minutes
after cooking is terminated in order to completely eliminate cooking
vapours and odours.
The proper function of the cooker hood is conditioned by the
regularity of the maintenance operations, in particular, the active
carbon filter.
• The anti-grease filters capture the grease particles suspended
in the air, and are therefore subject to clogging according to the
frequency of the use of the appliance.
In order to prevent fire hazard, it is recommendable to clean the
filter at a maximum of 2 months by carrying out the following
instructions:
- Remove the filters from the cooker hood and wash them in a
solution of water and neutral liquid detergent, leaving to soak.
- Rinse thoroughly with warm water and leave to dry.
- The filters may also be washed in the dishwasher.
The aluminium panels may alter in colour after several washes.
This is not cause for customer complaint nor replacement of panels.
• The active carbon filters purify the air that is replaced in the
environment. The filters are not washable nor re-useable and must
be replaced at maximum every four months. The saturation of the
active carbon filter depends on the frequency of use of the
appliance, by the type of cooking and the regularity of cleaning the
anti-grease filters.
• Clean the fan and other surfaces of the cooker hood regularly
using a cloth moistened with denatured alcohol or non abrasive
liquid detergent.
• COMANDS: 1A)LUMINOUS_1B)MECHANICAL (Fig. 5) the
key symbols are explained below:
A = LIGHT
B = OFF
C = SPEED I
D = SPEED II
E = SPEED III
F = AUTOMATIC STOP TIMER - 15 minutes
G = MOTOR WORKING indicator
The "Automatic stop timer" delays stopping of the hood, which will
continue functioning for 15 minutes at the operating speed set at
the time this function is activated.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR
EVENTUAL DAMAGES CAUSED BY BREACHING THE ABOVE
WARNINGS.
ENGLISH


Product specificaties

Merk: Etna
Categorie: Afzuigkap
Model: 4421 RVS

Heb je hulp nodig?

Als je hulp nodig hebt met Etna 4421 RVS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Etna

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap