Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
Guía de
instalación, uso y
mantenimiento
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0152213
Printed in Mexico
10/18
Models: KIT0154387
2
ENGLISH
Contents
Important safety notice................................................................................................................................................................................................. 3
Installation Requirements ................................................................................................. ........................................................................................... 4
Tools & Parts ................................................................................................................................................................................................................ 4
Location Requirements ........................................................................................................................................................................................... 5
Product Dimension ................................................................................................................................................................................................... 5
Venting Requirements ............................................................................................................................................................................................. 5
Electrical Requirements .......................................................................................................................................................................................... 6
Installation Instructions ................................................................................................................................................................................................ 6
Prepare the location ................................................................................................................................................................................................ 6
Install In-Blower System .......................................................................................................................................................................................... 9
Make electrical connection for the In-Line Blower System...................................................................................................................... 10
Make electrical between the In-Line Blower System and Range Hood .............................................................................................. 11
Warranty ........................................................................................................................................................................................................................... 14
Wiring Diagram .............................................................................................................................................................................................................. 43
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn o power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.
8
3 Remove the motor mounting plate by setting free the
spring clip. NOTE: The spring clip should be outside the
slot in the mounting plate.
A. Mounting plate
B. Spring Clip
A
B
A. Mounting plate
B. Spring Clip
A
B
4 Run out the power supply wires and connector through
the hole in the right end of the motor mounting plate.
5 Slide out the left mounting plate from under the motor
mounting bracket.
A
B
A. Motor mounting plate
B. Motor mounting bracket
6 Install the grease filters.
Prepare for Mounting the In-Line Blower System
The In-Line Blower System must be fastened to a secure
structure of the roof, ceiling, wall, floor, or new or existing
frame construction. The 4 holes on either the inlet (bottom)
side or the outlet (top) side of the blower must be used to
mount the in-line blower system to the structure.
NOTE: The mounting hole locations must span the studs.
Additional stud framing may be required. Plywood may be
used to span open areas between ceiling joists or roof rafters
to aid installation. This structure must be strong enough to
support the weight of the in-line blower system (50 lb [22.6
kg] min).
Prepare the In-line Blower System
I WARNING
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
1 Disconnect power.
2 Determine which venting method to use: roof or wall
exhaust.
3 Using two or more people, move the in-line blower motor
system to the mounting location.
4 Remove the 10 screws from the front cover of the in-line
blower motor housing and set them aside.
5 Remove the front cover of the in-line blower motor
housing and set it aside.
NOTE: To make the in-line blower motor housing easier to
mount, the blower motor assembly can be removed.
6 Disconnect the motor electrical plug from the blower
motor assembly.
7 Remove the screws that secure the blower motor
assembly to the in-line blower housing and set them aside.
8 Pull the spring clip to release the blower motor assembly.
Remove the blower motor assembly from the housing and
place it on a covered surface.
A
BC
D
A. Front cover
B. Blower mounting
screws
C. Spring clip
D. Motor electrical
plug


Product specificaties

Merk: Elica
Categorie: Afzuigkap
Model: Vavano EVV648S1