9
Install In-Blower System
NOTE: The blower motor housing can be mounted using
4 holes from either the inlet side or the outlet side of the
blower.
A
A
A
A
A
A
A. Mounting holes
1 Position the in-line blower motor housing in its mounting
location and mark the 4 mounting hole locations.
2 Drill 4 mounting pilot holes using a ³⁄₁₆” (0.5 cm) drill bit.
3 Attach the in-line blower motor housing to the mounting
location with mounting (4) 6.3x60 mm screws and
(4)4x1.8 washers(Parts are included with the range hood
motor kit)
4 If removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5 If removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1 Determine and make all necessary cuts for the vent
system. IMPORTANT: When cutting or drilling into the
ceiling or wall, do not damage electrical wiring or other
hidden utilities.
2 Determine the location where the ¹⁄₂” (1.3 cm) wiring
conduit will be routed through the ceiling or wall between
the in-line blower and the range hood.
3 Drill a 1¹⁄₄” (3.2 cm) hole at this location.
4 Locate the electrical terminal boxes in the in-line blower
housing and range hood Remove the terminal box covers .
and set the covers and screws aside.
A
B
A. Terminal Box Cover
B. Knockout
5 Remove the electrical knockout from the in-line blower
housing and range hood (see the range hood installation
instructions) to prepare for the installation of the UL
listed or CSA approved ¹⁄₂” (1.3 cm) wiring conduit and
conduit connector.
6 With the range hood mounted (see the range hood
installation instructions), run the ¹⁄₂” (1.3 cm) wiring
conduit between the in-line blower motor housing and the
range hood. Pull enough ¹⁄₂” wiring conduit to allow for
easy connection to the terminal boxes in the in-line blower
housing and range hood.
A
B
C
D
F
E
A. In-Line Blower Kit
B. Range Hood Terminal
Box
C. Power Supply wiring
Conduit
D. In-Line Blower Wiring
Conduit (not included)
E. In-Line Blower Terminal
Box
F. In-Line Motor Electrical
Plug Cable
11
Make Electrical Connection Inside Range Hood
Between In-Line Blower System
and Range Hood
1 With the range hood mounted (see the range hood
installation instructions), locate the wiring cable connector
inside the range hood.
C
D
A
B
A. Range Hood Junction Box
B. Range Hood knockout for Wire
Connector Assembly
C. Wire Connector Assembly (provided
in the In-Line Blower Kit)
D. Power Supply Wiring Conduit
2 Connect the 6 wire connector assembly supplied with
the in-line blower motor system to the mating connector
from the range hood.
BA
A. Wire Connector Assembly (provided in
the In-Line Blower Kit)
B. Hood Insert Blower Connector
3 Install UL listed or CSA approved strain reliefs. Run
through the strain reliefs the 6 wire connector
and the In-Line Blower wiring conduit (not incluided
leaving enough wire length to make the wiring
connections.
4 Tighten the strain relief screws.
5 Connect the wires from the 6- wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
Connect the green (or green/yellow) ground NOTE:
wire from the wiring conduit to the green (or bare)
ground wire from the home power supply and to the
and to the green/yellow ground wire from the 6-wire
connector assembly (H) using UL listed wire connectors
(see the “Make Electrical Power Supply Connections
to Range Hood” section in the range hood installation
instructions).
A
B
C
D
E
F
G
H
I
A. Strain relief
B. UL listed wire
connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or yellow/
green) and green /
yellow wires
I. Motor electrical plug
cable
6 Connect the home power supply wiring to the range
hood following the instructions that are supplied with the
range hood.
7 Reinstall the range hood terminal box cover.
8 Reconnect power.