Elica Calabria ECL142S3 Handleiding

Elica Niet gecategoriseerd Calabria ECL142S3

Lees hieronder de 📖 handleiding in het Nederlandse voor Elica Calabria ECL142S3 (44 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 39 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/44
Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
Guía de
instalación, uso y
mantenimiento
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0141105A
Printed in Mexico
01/19
Models: ECL630S4
ECL136S4
ECL142S4
ECL148S4
2
ENGLISH
Contents
Important safety notice................................................................................................................................................................................................. 3
Electrical & installation requirements ................................................................................................. ............................................................... 4
Before installing the hood ...................................................................................................................................................................................... 4
Dimensions and clearances......................................................................................................................................................................................... 5
List of materials................................................................................................................................................................................................................. 6
Parts supplied .............................................................................................................................................................................................................. 6
Parts not supplied ...................................................................................................................................................................................................... 6
Ducting options and examples.................................................................................................................................................................................. 7
Installation ......................................................................................................................................................................................................................... 8
Venting methods......................................................................................................................................................................................................... 8
Wall installation........................................................................................................................................................................................................... 9
Electrical connection................................................................................................................................................................................................ 11
Complete the installation........................................................................................................................................................................................ 11
Description of the hood................................................................................................................................................................................................. 11
Control.................................................................................................................................................................................................................................. 11
Maintenance ...................................................................................................................................................................................................................... 12
Warranty ........................................................................................................................................................................................................................... 13
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn o power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.
3
I IMPORTANT SAFETY NOTICE
I CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR
VAPOURS.
I WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning the unit, switch power o
at service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally.
When the service disconnecting means cannot be
locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
C. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable
codes & standards, including fire-rated construction.
D. Sucient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting.
Follow the heating equipment manufacturers guideline
and safety standards such as those published by the
national fire protection association (NFPA), the american
society for heating, refrigeration and air conditioning
engineers (ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
F. Ducted fans must always be vented to the outdoor.
I CAUTION
To reduce risk of fire and to properly exhaust air, be sure to
duct air outside - do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
I WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT
WORK.
Install this hood in accordance with all requirements specified.
I WARNING
To reduce the risk of fire or electric shock, do not use this
hood with any external solid state speed control device.
I WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (I.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
I WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:a
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or other metal tray, then turn o the gas burner or the
electric element. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL
THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and
you already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
aBased on “Kitchen Fire Safety Tips” published by NFPA.
CAUTIONI
Automatically Operated Device - To Reduce The Risk Of
Injury Disconnect From Power Supply Before Servicing.
I WARNING
To Reduce The Risk Of Fire And Electric Shock, Install This Rangehood Only With Integral, In Line, and External Blower Models
Rated Maximum 7.7 A/ 920 W Or Integral Blowers Manufactured by Elica (for model references, see optional accessories table).
Integral Blower
(already included
with the hood)
In Line
Blower Kit 1200
KIT0154387
External
Blower Kit 1200
KIT0153054
Heat Lamps Kit
(See accessories
table for reference)
Heat Lamps Kit +
In Line Blower Kit
Heat Lamps Kit +
External Blower Kit
HOOD MODEL A W A W A W A W A W A W
ECL630S4 3.9 913 884 6.8 583 10.4 1020 10.2 991463 7.7 7.4
ECL136S4 913 913 884 10.5 1033 10.4 1020 10.2 9917.6 7.6 7.4
ECL142S4 913 913 884 10.5 1033 10.4 1020 10.2 9917.6 7.6 7.4
ECL148S4 10.6 1040 10.4 1020 10.2 9917.7 7.7 7.5920 920 891