Electrolux EWE351LB-DAX1 Handleiding

Electrolux Ketel & boiler EWE351LB-DAX1

Lees hieronder de 📖 handleiding in het Nederlandse voor Electrolux EWE351LB-DAX1 (2 pagina's) in de categorie Ketel & boiler. Deze handleiding was nuttig voor 45 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
EN ELECTRIC WATER HEATER USER MANUAL
1. PARTS IDENTIFICATION
1. Front Cover
2. LED Indicators
i) Earth LED Indicator
ii) Power/ELCB LED Indicator
3. Test / Reset Button
4. Rating Label
5. Pump Button*
6. Temperature Control Knob
7. 3 in 1 Stop Valve
i) Stop Valve Lever
ii) Flow Regulator Valve Adjustment
iii) Built-in-Filter
8. Mesh Filter
9. Rain Shower Head
10. Rail Bracket
11. Handshower
12. Adjustable Shower Holder
13.
PVC Hose (1.5 meter)
14. Soap Tray
15. Slider Rail
16. PVC Hose (1.0 meter)
17. Selector Valve
18. Heater Base
19. Terminal Block
20. Thermostat (Double-Action)
21. Heater Tank
22. PCB Board (Test & Reset)
23. VR Board
24. Main/ELCB Board**
25. Water Outlet Connection
26. D.C. Silent Pump*
27. TRIAC
28. Reed Switch Assy***
29. Water Inlet Connection***
30. SMPS PCB Board
Fig 1.
18
19
21
22
25
24
27
28
29
20
7
8
18
19
21
22
25
24
30
27
28
29
20
7
8
26
9
10
11
12
13
14
15
17
16
7
8
1
3
6
4
31
No Pump Model DC Pump Model
2. SAFETY INFORMATION
2.1 Pr uc ma fa ur b afe od ts nu ct ed y Electrolux are s
provided t y are inst l , us and ma tained he al ed ed in
in wor ing good k order accordance th o in wi ur
ins ru on andt cti s reco tions. Al s ref mmenda way er
to t s ma l if you have any do t. hi nua ub
2.2 The E at ter be t d. lectric W er Hea must ear he
Impro grper oundi ulng co d cause electrical k.shoc
2.3 If any o followi tion occ as f the ng condi s ur
shown below, im diat y swi h ofme el tc f the power
s y c tac heuppl and on t t Elect x rolu Consumer
2.6 e the ic Wh n Electr Water Heater s i
u y some e such as c d, e erly sed b on hil ld
p on, sick a i y ers person nd phys call
ha ed p thendi ppca erson, person
concerne s k y re ted to ay d i indl ques p
atte ecknt a chion nd the shower
temp ureerat by ha from time t time.nd o
2.7 ng l t g/t der, tch off the r Duri igh nin hun swi powe
supply to the E at ter to protect lectric W er Hea in advance
t Whe E tlec ric at ter against s e da ge.er Hea po sibl ma
2.8 The h c t uity c uctor of the ele ical eart on in ond ctr
inst at n stall io mu be effe ively co t a ct nnected o ll
ex sed metal p s of other a lian a po art pp ces nd
serv cei s the rin oo wh Electr aterm, ich in the ic W
Heater is to be linsta le to c fo t l d on rm o loca
re s and ensure pr ng/gr gulation oper earthi ounding
for t e i . ELCB o b effect ve
NOTE : W rem ng the hen ovi E at terlectric W er Hea
from package, a sma a nt of ter ma be ll mou wa y
f . This is normal as the ound inside E at lectric W er
Heater is te risted du ng anu m fact ng process. uri
WARNING !
.
.
.
.
.
If the E t at ter begins to make an lec ric W er Hea
odd noise, smell or smoke.
If ELCB trips and E at ter Indicator lectric W er Hea
does not light up.
Water temperature cannot be controlled.
If the E t at ter shows signs of a lec ric W er Hea
distinct change in performance.
If water leaks from inside.
2.10 Insta ation mu e carried out by a ll st b
qu er nnalified p so el a n compliance lo l nd i ca
2.11 This mu be Electric r Water Heate st
p manently c ed to the irect mainer onnect d line
s ply. A plug up a socket is not recommended nd
to be used.
2.12 For the correct size of wire c uctor ond
corresponding to different ele i l loa s, ctr ca ding
2.13 This operates at a Electric r Water Heate
minimum w r ate ow te f 2.0 litre/minra o
a maximum worknd ing
pre ure of 6 s. For direct c ne ion from ss bar on ct
the water nk, the ta
2.14 The ll t f ion Electric r Water Heate wi no unct
if there is insuf cient wa r ow (min 2.0 litre/min) te
2.15
The ilt- auto i y cut bu in EL will CB mat call off
the s ply power up in case there is a current
2.16
The thermo will automati lly cut off the stat ca
power s ply if it has sense an abnormal rise up d in
water p ure.tem erat
CAUTION !
aut ri ho ty regulations.
please refer t a e 1.o T bl
Electr ater Heateic W r must
have an stallati minimum 1.0m below the in on
w nk.ater ta
to igger the tr ow switch.
leakage over 15mA.
Care terCen . Never a o c ttempt t repair t Ehe lectri
Wat ter y s f: er Hea our el
2.5 i i c F Por ump Model, t s highly re ommended
to at o connec het t W er I tnlet Connection tank
st ot se i se orage supply, herwi t may cau damage
to t . t Phe ump Mo or
User se is advi d to t a a the tes nd djust
water temp ure before sing.erat u
2.9 WARNING : Metallic / chromed hose and
conductive control valve shall not be used.
Fig.3
RAIL BRACKET COVER & CAP DISMANTLE STEPS
1
RAIL BRACKET
2
OPEN THE RAIL
BRACKET COVER
B TURNING ANTI Y
CLOCKWISE &
USING SCREW
DRIVER O OPEN T
THE CAP
3
RAIL BRACKET
COVER
COME-OUT
3.
ELECTRIC WATER HEATER UNIT INSTALLATION
RAIN SHOWER SET INSTALLATION PROCEDURES
connect to
water outlet
connection
ELECTRIC WATER HEATER
UNIT INSTALLATION DIAGRAM
Fig. 2
Screw
A
3 in 1
stop valve
inlet
Wall
285.5mm
Washer
connect to
water inlet
connection
Min.
80 mm
150mm
3.1 Select a suitable position in the bathroom.
3.2 Remove the screw (A) at the bottom of the
E t at terlec ric W er Hea
. (Fig. 2)
3.3 Remove the Front Cover from the bottom and then lift up the front cover.
3.4 Mark 3 Screw points of the Heater Base on the wall. The
E t at terlec ric W er Hea
position
should be 1.5m above the bathroom floor. (Fig. 2)
3.5 Use 6mm diameter drill and make the wall plug holes in depth of 34mm.
3.6 Insert the wall plugs and mount the
E t at terlec ric W er Hea
firmly in position with the
screws provided.
shower
holder
rail bracket
slider rail
selector valve
38mm
38mm
1300mm 650mm
wall plug hole
screw
mounting terminal
1. 2.
3. 4.
STEP 1
Insert the Top Rail Bracket, Adjustable
Shower Holder , & Bottom Soap Tray
Rail Bracket to the Slider Rail.
STEP 2
Connect the Selector Valve to the
bottom of Slider Rail.
STEP 3
Select a suitable position for the Rain Shower
Set then mark 4 screws point (2 on top and 2
on bottom).The gap of 2 screw hole was 38mm.
It is recommended that the Top Rail Bracket
position at height of 1950mm to the floor and
Bottom Rail Bracket 1300mm to the floor.
wall plug
STEP 4
Use 6mm diameter drill and make the wall plug
holes in depth of 34mm. Insert the wall plugs
and mounting terminal firmly in position with
the screw provided.
RAIN SHOWER SET INSTALLATION
PROCEDURES (CONT’D)
soap
tray
rail
bracket cap
hexagon tool
plastic nut
STEP 5
Mount the Slider Rail (connected with Rail
Bracket, Adjustable Shower Holder and Selector
Valve) to the mounting terminal by turns the
terminal cover.
5. 6.
STEP 6
Remove the cover and cap from the Rail Bracket
(Fig. 3A) and screw the rail bracket by turning the
cover clockwise. Using hexagon tool to tighten the
plastic nut to the desire position and then replace
the cover.
1200mm
650mm
100mm
PVC hose
rain
shower
head
shower
head
7. 8.
STEP 7
Connect the Rain Shower Head to the top of
Slider Rail, 1.5Meter PVC Hose to Hand Shower
Head and 1Meter PVC Hose to the Heater.
Connected be sure to put in the Rubber Washer.
STEP 8
Recommended Height for Rain Shower Set.
rail bracket
cover
rubber
washer
RAIN SHOWER SET INSTALLATION
PROCEDURES (CONT’D)
1 2
3 4 5
EWE351LB-DAX1
EWE601LX1DIX1
REV 1
(2.5 litre/min for 6.0kW)
/ 2.5 litre/min for 6.0kW)
2
5
*
*
* For Pump Model only
** Pump Model VR Board & Main/ELCB Board combine.
* **
**
2.4 If the Red (POWER) Indicator does not go off
when you turn off the water, switch OFF the
mains supply and contact Electrolux Consumer
Care Centre for repair service.Special skill is
required for repairing.
NEVER try to repair the unit by yourself.
31. Pump Board
23
32
32. Temperature Knob LED Light
***
***
*** No pump Model 6.0kW using Flow Sensor Assembly.
4. PLUMBING PROCEDURE
CAUTION! IMPORTANT
This Electric Water Heater is a single point
system and the “Water Outlet” can only be
fitted to the Hose and Handshower set
provided. MUST NO O CONNECT T T
CONTROL VALVE OR FITTING CAN BE
FITTED O THE WATER OUTLET. T
WARNING!
4.1 Connect the 3 in 1 Stop Valve to the Water
Inlet with washer. Use correct tools to tighten
and be careful not to over tighten and damage
the plastic nut.
4.2 Connect the incoming water piping to the 3 in
1 Stop Valve (1/2” BSP).
Make sure to put the Mesh Filter between 3
in 1 Stop Valve and incoming water piping.
4.3
If in any case, the 3 in 1 Stop Valve is not use or
omitted, make sure to put the Mesh Filter
between the Electric Water Heater inlet pipe
and incoming water pipe.
4.4 Turn on the water mains to drain out all plumbing
dirts before connecting the water supply to the
Electric Water Heater, the water supply to the
Electric Water Heater must be free from mud and
dirt. Always KEEP the water supply to the Electric
Water Heater free from mud and dirt at all time
during usage.
4.6 Hook the Handshower to the Slider Rail
Shower Holder and adjust to your ideal position.
4.7 Check if any water leakage.
4.8 Do not use sealing tape during piping
installation.
THE HEATER TANK MUST BE FILLED UP WITH
WATER BEFORE TURNING ON THE POWER
SUPPLY TO PREVENT ANY DRY BURNT DAMAGE
TO THE HEATING ELEMENT.
4.5 Connect the Hose and Handshower to the
outlet of Electric Water Heater, be sure to put in the
Washer in between the connection. (Fig. 2)
4.10 DO NOT APPLY PLUMBING CEMENT ON
CONNECTION. WHENEVER NECESSARY, USE
ONLY THREAD OR SEALING TAPE.
4.9 THE WATER INLET AND OUTLET MUST BE
INSTALLED CORRECTLY, OTHERWISE ELECTRIC
WATER HEATER WILL NOT FUNCTION.
5. ELECTRICAL INSTALLATION
WARNING! PROCEDURE :
5.6 ns I er het t wall embedded cable through
S nt ‘A’ u a a ce ide E ry by c tting hole t the sour
cord rubber holder and lead he able Cable t c to
B c ‘B (F 6)ra ket . ig.
5.7 : cConnec het t able as following
BR N RED )OW or --LIVE (L
B LAC EUTRAL )LUE or B K --N (N
GR N R N RTH ( )EE or G EE /YELL --EAOW
5.8 o sit . tClamp he cable t the correct po ion
CH G NN TIOEC H RINK IF T E WI CO EC N IS
CO EC ce .RR T and repla t che over
5.9 , When putting bac hek t Front Cover
plea ake nose t te o hef t
pro edure shown belowc :
-Ens t i ure the posi ion s correc urnt, t the
T t t o empera ure Con rol K Inob nsert t OFF
posi ion hown in ig.A t as s F (At the Heater ase B )
Cable
Fig. 4
Brown or Red = Live (L)
Blue or Black = Neutral (N)
Green or Green/ Yellow = Earth ( )
Fig. 5
Fuse Distributor Board
Miniature Circuit Breaker (MCB)
ON/OFF Double Pole Switch
Double PVC cable
NOTE:
Refer to TABLE 1 for electrical loading and
correct size of wire conductor
METHOD OF ALIGNMENT WHEN REPLACING FRONT COVER
5.1 This Electric Water Heater must be
earthed. Improper grounding could cause
electrical shock.
5.2 Remember to SWITCH OFF the power
supply before carrying out any electrical work.
5.3 Refer to TABLE 1 for the correct cable
size.
5.4 Use double insulation cable of over
2.5mm² for 3.5kW and 4.0mm² for 6.0.kW.
5.5 Lead the power cable from MCB to a
“ON/OFF’’ double pole Linked Switch
having a contact separation of at least 3mm
in all poles outside the bathroom, then lead
a cable to the terminal block inside the
Instant Hot Shower. (Fig. 4)
Front CoverFig A Fig B
Fig. 6
A
B
Position
this Way
Position
this Way
6. TABLE 1 - CABLE SIZE TABLE
7.
TEST RUN
Voltage Power Current
(AC) (kW) (A)
3.5 15.9 2.5 7 / 0.67mm 50/ 0.25 mm 20 20
220V ~
50/60 Hz
Conductor Size (csa)
mm Conduit Cable Flexible Cable
On/ Off Fuse /
Switch (A) MCB (A)
2
7.1 Turn on the water supply and 3 in 1
Stop Valve, the water will flow through the
Handshower.
7.2 Switch on the power supply. The 3
LED Indicator light shall run ON/OFF 3
times in sequences to indicate the set are
self checking.
If the
Electric Water Heater
is not earthed
properly, the Earth Led indicator light will
OFF, during usage or standby. Earth Led
indicator light also OFF if Live & Neutral
reverse connection.
7.4 The
Electric Water Heater
might not be
hot enough even at the ‘MAX’ position if
incoming water supply from the mains is too
cold or the pressure of water is too high. In
this case, you may adjust the 3 in 1 Stop Valve
to reduce the water inflow in order to get the
desired showering temperature. (Recommended
flow rate of below 6litre/min)
7.5 Check the Built-in ELCB as following:
- Press the “TEST” Button, the Built-in ELCB
should trip and cut off the power supply, ELCB
and Power Indicators should light off.
-Press the “RESET” Button, the 3 LED Indicator
light shall run ON/OFF 3 times in sequences to
indicate self checking as in 7.2 above and the
Electric Water Heater
should resume normal
function, the Green LED Indicator should light on.
If procedures stated above prevailed, the ELCB is
functioning in normal condition.
7.6 The height and direction of Shower
Holder are adjustable by releasing the shower
holder knob clockwise and anticlockwise.
7.7 Move the Handshower to the desired
angle. ratchet mechanism in the Shower A
Holder will hold the Handshower in selected position.
7.8 It is unnecessary to turn the Temperature
Control Knob to “OFF” position when the
Instant Hot Shower is not in use.
7.9 Switch OFF the power supply after shower.
7.10 For Pump model:
The pump will auto ON when power ON and
3 in 1 stop valve open (and there is water supply)
7.11 Booster Pump Function:
After incoming power supply is ON, and water
supply flow through 3 in 1 stop valve while open
position but the water flow rate is not sufficient to
activate the flow sensor, Booster Pump Function
can be useful to help to increase the incoming water
flow rate. Press the pump button to activate the booster
pump function. The booster pump function will be ON to
increase the incoming water flow rate. While the Booster
Pump Function is working and the incoming water flow
rate can be maintained above flow sensor activation level,
the Electric Water Heater will be resumed working
continuously as normally. If the incoming flow rate can
not be maintained above flow sensor activation level,
the Booster Pump Function will be auto OFF and the
Electric Water Heater will not be able to function normally
due to incoming flow rate is too low. (Advisable to avoid
applying Booster Pump Function to increase the incoming
water flow rate more than 3 times of each showering).
8. HANDSHOWER SPRAY
9. MAINTENANCE
Clean the Handshower Head holes by using the soft brush from time to time.
(Recommended once a week)
Note: Take care not to damage the holes of the Handshower Head during cleaning.
Fig. 8 Fig. 9
FILTER UNIT CLEANING
CLOSEOPEN
INTERNAL
STRAINER
OPEN CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
This Innovative adjustable Handshower has 5 different spray patterns (STANDARD, JUMBO, SOOTHE, MIX
and MASSAGE. The patterns are described as following:
Fig. 7
STANDARD SPRAY SOOTHE SPRAY JUMBO SPRAY MIX SPRAY MASSAGE SPRAY
9.1 TES THE ‘ELCB’ REGULARLY T
(This procedure is highly recommended test at
least once a month)
9.2 CLEAN THE FILTER REGULARLY
Clean the Mesh Filter regularly to prevent
blockage (Fig. 8) . Remove the Built-in Filter by
turning its cap anticlockwise. Whenever need to
Read the section ‘ SAFETY INFORMATION ’ first.
WARNING!
9.3 If the Red (POWER) Indicator does not
go off when you press the ELCB Test Button,
switch OFF the mains supply and contact
Electrolux Consumer Care Centre for repair
service. Special skill is required for repairing.
NEVER try to repair the unit by yourself.
9.4 CLEANING PRECAUTION !
Do not use thinner,alcohol,petrol or any other
organic solutions to clean the set. Use only
damped cloth with mild detergent.
flush the internal stainer with water to remove
any trapped sediments. Whenever fixing back
the Built-In Filter, beware of the alignment of
Internal Strainer. Use the protruded guideline
within Stop Valve to position the Internal
Strainer.
10. WIRING DIAGRAM
* Manual Reset (90° C Thermostat)Thermostat
For Models rated 4.8kW and below, thermostat is manually resetable.
For models rated 6.0kW and above, thermostat needed to be replaced once permanently tripped.
11.
ELECTRICAL SPECIFICATION
Note : The specification, actual product’s cosmetic design and accessories parts shown are
correct at the time of printing and may be subjected to change without prior notice.
1.5 kg - ELCB , DPDT , NO PUMP / 1.7 kg for 6.0kW Models
2 Litre / min (2.5 Litre/Min for 6.0kW model only)
ELECTRONIC POWER CONTROLTYPE
ELECTRICAL LOADING
Min. WATER FLOW RATE
WATER CONNECTION
DIMENSIONS
NETt WEIGHT
3.5kW to 6.0kW 220V a.c. 50/60Hz
1/2” BSP SINGLE POINT SYSTEM
220 (W) X 401 (H) X 90 (T) mm
6.0 Bar (0.6 MPa ; 87.02 psi)
Max. INLET WATER PRESSURE
Min. INLET WATER PRESSURE
0.1 Bar (10 kPa ; 1.45 psi)
2.0 kg - ELCB , DPDT , DC PUMP
CONSUMER CARE
Indonesia
Hotline service: 08041119999
PT. Electrolux Indonesia
Electrolux Building
Jl.Abdul Muis No.34, Petojo Selatan,
Gambir Jakarta Pusat 10160
Email:customercare@electrolux.co.id
SMS & WA : 0812.8088.8863
Malaysia
Consumer Care Center Tel: 1300-88-11-22
Electrolux Home Appliances Sdn. Bhd.
Corporate Office Address: Unit T2-7, 7th Floor, Tower 2 ,
Jaya33 Hyperoffice, No. 3, Jalan Semangat, Seksyen 13,
46100 Petaling Jaya, Selangor
Office Tel : (+60 3) 7843 5999
Office Fax : (+60 3) 7955 5511
Consumer Care Center Address: Lot C6, No. 28,
Jalan 15/22, Taman Perindustrain Tiong Nam,
40200 Shah Alam, Selangor
Consumer Care Center Fax : (+60 3) 5524 2521
Email : malaysia.customercare@electrolux.com
Philippines
Consumer Care Center Toll Free : 1-800-10-845-CA RE 2273
Consumer Care Hotline : (+63 2) 845 CARE 2273
Electrolux Philippines, Inc.
10th Floor. W5th Avenue Building
5th Avenue Corner 32nd Street
Bonifacio Global City,
Taguig Philippines 1634
Trunkline: +63 2 737- 4756
Website : www.electrolux.com.ph
Email : wecare@electrolux.com
Singapore
Consumer Care Center Tel: (+65) 6727 3699
Electrolux S.E.A. Pte Ltd.
1 Fusionopolis Place,
#07-10 Galaxis, West Lobby
Singapore 138522.
Office Fax : (+65) 6727 3611
Email : customer-care.sin@electrolux.com
Thailand
Consumer Care Tel : (+66 2) 725 9000
Electrolux Thailand Co., Ltd.
Electrolux Building 14th Floor
1910 New Phetchaburi Road,
Bangkapi, Huai Khwang, Bangkok 10310
Office Tel : (+66 2) 7259100
Office Fax : (+66 2) 7259299
Email : customercarethai@electrolux.com
Vietnam
Consumer Care Center Toll Free : 1800-58-88-99
Tel : (+84 8) 3910 5465
Electrolux Vietnam Ltd.
Floor 9th, A&B Tower
76 Le Lai street - Ben Thanh Ward - District 1
Ho Chi Minh City Vietnam
Office Tel : (+84 8) 3910 5465
Office Fax : (+84 8) 3910 5470
Email : vncare@electrolux.com
Hongkong
Tel: (+852) 8203 0298
Dah Chong Hong, Ltd. - Service Centre
8/F., Yee Lim Godown Block C
2-28 Kwai Lok Street, Kwai Chung, N.T.
67 8
9 10 11
WIRING DIAGRAM -WITH ELCB, DC PUMP DPDT MODEL (FOR VIETNAM MODELS ONLY)
LIVE
NEUTRAL
TRIAC
Relay 1 Lout
Relay 2 Nout
(N
in
)
(L
in
)
Auto-Re set * Manu al -Reset
Power Supply
220/230/240 V~a.c.
Double Action T herm ostat
T2
G
Electroni c
ELCB,15mA
Sensiti vity
Reset
Test
Heater Control
On/Off Switch
Power On/O ff
Temperature Control
Heat ing Element A
Heat ing Element B
Relay 3
SMPS PCB
ASSY
Silent Pump
VR LED BOARD
Pump Button
6.0 27.3 4.0 7 / 0.85mm 56 / 0.30 mm 32 32
7.3
The hot water will flow out within a few seconds.
The more
Temperature Control Knob being
turned in clockwise direction, the hotter is the
water.
Indicator light will turn on from minimum position
is WHITE color gradually change to PINK color
at the medium position and gradually change to
RED color at the maximum position.
Turn on the power supply and water supply,
both Red (HEATER) and Green (ELCB) Indicators
will light up if the Temperature Control Knob is in
‘ON’ position and Red Temperature Control Knob
Indicator light will turn on from minimum position
is WHITE color gradually change to PINK color
at the medium position and gradually change to
RED color at the maximum position. Press the
ELCB Test Button, both POWER, ELCB and
Temperature Control Knob Indicators should go
off. Press the Reset Button to resume the power
supply.
Turn on the power supply and water supply, both
Red (HEATER) and Green (ELCB) Indicators will
light up if the Temperature Control Knob is in ‘ON’
position and Red Temperature Control Knob
LIVE
NEUTRAL
Power On/Off
Temperature Control
TRIAC
Lout
Nout
(N
in
)
(L
in
)
Auto-Re set * Manu al -Reset
Power Supply
220/230/240 V~a.c.
Double Action T herm ostat
Electroni c
ELCB,15mA
Sensiti vity
Reset
Test
T2
G
Heater Control
On/Off Switch
Relay 1
Relay 2
VR LED BOARD
WE’RE THINKING OF YOU
Thank you for purchasing an Electrolux appliance. You’ve chosen a product that brings with
it decades of professional experience and innovation. In genious and stylish, it has been
designed with you in mind. So whenever you use it, you can be safe in knowledge that
you’ll get great results every time. Welcome to Electrolux.
Visit our website to:
Get usage advice, brochures, trouble shooter, service information:
www.electrolux.com
Register your product for better service:
www.registerelectrolux.com
Buy Accessories, Consumables and Original spare parts for your appliance:
www.electrolux.com/shop
CONSUMER CARE AND SERVICE
We recommend the use of original spare parts.
When contacting Service, ensure that you have the following data available.
The information can be found on the rating plate. Model, PNC, Serial Number.
(Right side of unit).
Warning/ Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
-
Install the Front Cover,turn the Temperature
Control Knob to OFF position to align with the
VR shaft as shown in Fig.B (At the Front Cover)
5.10 Fix the Temperature Control Knob and
screw ‘A’ (Fig. 2).
Reconnect the Temperature Knob LED Light
wire to Main Board (J5 Connector).


Product specificaties

Merk: Electrolux
Categorie: Ketel & boiler
Model: EWE351LB-DAX1

Heb je hulp nodig?

Als je hulp nodig hebt met Electrolux EWE351LB-DAX1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Ketel & boiler Electrolux

Handleiding Ketel & boiler

Nieuwste handleidingen voor Ketel & boiler