Electrolux EFC6941 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Electrolux EFC6941 (16 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 49 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
Gebrauchsanweisung , Notice d'utilisation et d'installation, Istruzioni per l'uso, User manual
EFC 6940 - EFC 6941
EFC 1410
F ID
Installatie- en gebruiksaanwijzing, Instrucciones de montaje y manejo, Manual de Instruções
UK
SM 8090
SM 8060
SM 8091 SM 8092
SM 8062
SM 8093
NL
EFC 6940-
6941
EFC 1410
E P
Contents UK
Before you use the cooker hood we recommend that you read through the whole user manual giving a direct
description of the cooker hood and its functions.
To avoid the risks, that are always present when you use a product driven by electricity, it is important that the
cooker hood is installed correctly and that you read the safety instructions carefully to avoid misuse and hazard.
Save the instruction manual and keep it available at use of the cooker hood
Safety warnings................................................................................................................................................... 36
for the installer ....................................................................................................................................................... 36
for the user............................................................................................................................................................. 36
Description of the appliance ............................................................................................................................ 37
Extractor version.................................................................................................................................................... 37
Filter Version .......................................................................................................................................................... 37
Control Panel - EFC 6940-6941 ...................................................................................................................... 38
Control Panel - EFC 1410 ................................................................................................................................39
Maintenance and care ....................................................................................................................................... 40
Cleaning ................................................................................................................................................................. 40
Metal grease filter .................................................................................................................................................. 40
Charcoal filter ........................................................................................................................................................ 41
Changing the light bulb ........................................................................................................................................... 41
What to do if ....................................................................................................................................................... 42
Technical Specifications .................................................................................................................................... 42
Special accessories............................................................................................................................................ 42
Technical assistance service............................................................................................................................ 43
Installation .......................................................................................................................................................... 45
Electrical connection .............................................................................................................................................. 45
Mounting accessories included .............................................................................................................................. 45
Wall unit mounting .................................................................................................................................................. 46
Special accessories/Vapour screen ................................................................................................................. 83
Safety warnings
for the installer
When used as an extractor unit, the hood must
be fitted with a 150mm diameter hose.
Should there already be a pipe of diameter 125
mm that ducts to the outside through the walls
or roof, it is possible to use the 150/125 mm
reduction flange provided. In this case the hood
will be slightly more noisy.
When installing the hood, make sure you
respect the following minimum distance
from the top edge of the cooking hob/ring
surfaces:
electric cookers 500 mm
gas cookers 650 mm
coal and oil cookers 700 mm min.
The national standard on fuel-burning systems
specifies a maximum depression of 0.04 bar in
such rooms.
The air outlet must not be connected to chimney
flues or combustion gas ducts. The air outlet
must under no circumstances be connected to
ventilation ducts for rooms in which fuel-burning
appliances are installed.
It is advisable to apply for authorization from the
relevant controlling authority when connecting
the outlet to an unused chimney flue or
combustion gas duct.
The air outlet installation must comply with the
regulations laid down by the relevant authorities.
When the unit is used in its extractor version, a
sufficiently large ventilation hole must be
provided, with dimensions that are
approximately the same as the outlet hole.
National and regional building regulations
impose a number of restrictions on using hoods
and fuel-burning appliances connected to a
chimney, such as coal or oil room-heaters and
gas fires, in the same room.
Hoods can only be used safely with appliances
connected to a chimney if the room and/or flat
(air/environment combination) is ventilated from
outside using a suitable ventilation hole approxi-
mately 500-600 cm2 large to avoid the
possibility of a depression being created during
operation of the hood.
If you have any doubts, contact the relevant
controlling authority or building inspectors
office.
Since the rule for rooms with fuel burning
appliances is outlet hole of the same size as the
ventilation hole, a hole of 500-600 cm2, which
is to say a larger hole, could reduce the perfor-
mance of the extractor hood.
If the hood is used in its filtering function, it will
operate simply and safely in the above
conditions without the need for any of the
aforementioned measures.
When the hood is used in its extractor function,
the following rules must be followed to obtain
optimal operation:
 short and straight outlet hose
keep bends in outlet hose to a minimum
 never install the hoses with an acute angle,
they must always follow a gentle curve only
 keep the hose as large as possible
(preferably the same diameter as the outlet
hole).
Failure to observe these basic instructions will
drastically reduce the performance and increase
the noise levels of the extractor hood.
for the user
Always cover lighted elements, to prevent
excess heat from damaging the appliance. In
the case of oil, gas and coal fired cookers it is
essential to avoid open flames.
Also, when frying, keep the deep frying pan on
the cooker top/cooker under careful control.
The hot oil in the frying pan might ignite due to
overheating.
The risk of self-ignition increases when the oil
being used is dirty.
It is extremely important to note that
overheating can cause a fire.
Never carry out any flambé cooking under
the hood.
Always disconnect the unit from the power
supply before carrying out any work on the
hood, including replacing the light bulb
(take the cartridge fuse out of the fuse holder or
switch off the automatic circuit breaker).
It is very important to clean the hood and
replace the filter at the recommended
intervals. Failure to do so could cause
grease deposits to build up, resulting in a
fire hazard.


Product specificaties

Merk: Electrolux
Categorie: Afzuigkap
Model: EFC6941

Heb je hulp nodig?

Als je hulp nodig hebt met Electrolux EFC6941 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Electrolux

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap

Miele

Miele DA 6520 D Handleiding

21 November 2024
Miele

Miele DA 420-4 Handleiding

21 November 2024
Miele

Miele DA 2660 Handleiding

21 November 2024
XO

XO R230W Handleiding

21 November 2024
Ilve

Ilve AGK90 Handleiding

20 November 2024
Ilve

Ilve AGQ90 Handleiding

20 November 2024
Ilve

Ilve AGQ60 Handleiding

20 November 2024
Ilve

Ilve AGQ120 Handleiding

20 November 2024
Ilve

Ilve AGK120 Handleiding

20 November 2024