Dometic EI540 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Dometic EI540 (30 pagina's) in de categorie Koelkast. Deze handleiding was nuttig voor 15 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/30
COPYRIGHT © 2008-2019 Dometic Corporation. All Rights Reserved.
No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means
electronic, mechanical, photocopying,recording or otherwise without prior written consent by Dometic Marine. Every precaution has
been taken in the preparation of this manual to insure its accuracy. However, Dometic Marine assumes no responsibility for errors
and omission. Neither is any liability assumed for damages resulting from the use of this product and information contained herein.
Eskimo Ice Crushed Ice System
Installation & Operation Manual
FOR MODEL EI540D
USING DIGITAL C (WONTROLS ITH C-19 SOFTWARE)
EI540D Digital Optional
Remote Display
Display
Dometic Corporation
Rev. A
L-3040 English
P/N 336124
L-3040 ENGLISH
Table of Contents
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
WARNINGS AND NOTICES . . . . . . . . . . . . . . . . . . . . . . 1
I CE MAKING AND R . . . . . . . . . . 2EFRIGERATION BASICS
How Ice Is Made . . . . . . . . . . . . . . . . . . . . . . . . 2
The Refrigeration Process . . . . . . . . . . . . . . . . 2
THE EFFECT OF TEMPERATURE ON ICE PRODUCTION . 3
Water Temperatures . . . . . . . . . . . . . . . . . . . . . 3
Air Temperature . . . . . . . . . . . . . . . . . . . . . . . . 3
COMPONENTS OF THE ICE MAKER . . . . . . . . . . . . . . . 4
Ice-Making Unit . . . . . . . . . . . . . . . . . . . . . . . . . 4
Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Ice-Storage Box . . . . . . . . . . . . . . . . . . . . . . . . 5
Seawater System . . . . . . . . . . . . . . . . . . . . . . . 5
Freshwater Supply . . . . . . . . . . . . . . . . . . . . . . 5
Refrigerant Charge . . . . . . . . . . . . . . . . . . . . . . 5
Thermal Expansion Valve (TXV) . . . . . . . . . . . . 5
INSTALLATION PROCEDURES . . . . . . . . . . . . . . . . . . 6
CHOOSING THE CORRECT EQUIPMENT VOLTAGE . . . . . 6
INSTALLING THE UNIT . . . . . . . . . . . . . . . . . . . . . . . . . 6
Selecting the Site . . . . . . . . . . . . . . . . . . . . . . . 6
Mounting the Unit . . . . . . . . . . . . . . . . . . . . . . . 6
Installing Condensate Drainage . . . . . . . . . . . . 6
Installing Ice-Delivery Hose . . . . . . . . . . 7 . . . . .
Installing the Ice-Level Sensor . . . . . . . . . . . . . 8
Installing the Feedwater System . . . . . . . . . . . . 8
Installing the Seawater Cooling System . . . . . . 9
Installing the Remote Digital Display . . . . . . . 13
Mandatory System Start-Up Test . . . . . . . . . . 13
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
THE DIGITAL CONTROL . . . . . . . . . . . . . . . . . . . . . . . 14
BASIC F . . . . . . . . . . . . . . . . . . . . . . . . . . 15UNCTIONS
Applying Power . . . . . . . . . . . . . . . . . . . . . . . . 15
On/Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Ice Bin Sensor . . . . . . . . . . . . . . . . . . . . . . . . 15
Operational LEDs . . . . . . . . . . . . . . . . . . . . . . 15
Operational Information . . . . . . . . . . . . . . . . . 15
Fault History . . . . . . . . . . . . . . . . . . . . . . . . . . 15
FAULTS HAT - EVENTS T INTERRUPT ICE PRODUCTION 15
FULL – Ice Bin Full . . . . . . . . . . . . . . . . . . . . . 15
H20 – Potable Water Switch . . . . . . . . . . . . . . 15
HPF – High Pressure Refrigerant . . . . . . . . . . 15
LAC – Low AC line voltage . . . . . . . . . . . . . . . 16
LPF – Low Pressure Refrigerant . . . . . . . . . . 16
OCA – Over Current Auger and Ice Delivery
Problem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
OCC – Overload Current Compressor . . . . . . 16
SPt – Auger Spout Blockage . . . . . . . . . . . . . 16
UCA – Under Current Auger . . . . . . . . . . . . . . 16
UCC – Under Current Compressor . . . . . . . . . 16
THE CYCLE OF OPERATION . . . . . . . . . . . . . . . . . . . 17
PROGRAMMABLE PARAMETERS FOR SOFTWARE 18
PROGRAM PARAMETER DESCRIPTIONS . . . . . . . . . . . 18
PROGRAM PARAMETER D SEFAULT ETTINGS . . . . . . . 18
STARTING THE SYSTEM . . . . . . . . . . . . . . . . . . . . . . 19
S -TART UP CHECK LIST . . . . . . . . . . . . . . . . . . . . . . . 19
S -TART UP PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . 19
SYSTEM SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . . . . 19
TEMPORARY SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . 19
SUSTAINED SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . 19
SYSTEM RESTART/RESET . . . . . . . . . . . . . . . . . . . . . 19
SERVICING THE SYSTEM . . . . . . . . . . . . . . . . . . . . . . 20
REFRIGERANT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
R-404A TOOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
THERMAL E VXPANSION ALVE (TXV) . . . . . . . . . . . . . 20
RECHARGING THE SYSTEM . . . . . . . . . . . . . . . . . . . . 20
System Shutdown . . . . . . . . . . . . . . . . . . . . . . 20
Evacuate Refrigerant . . . . . . . . . . . . . . . . . . . . 20
Charging the System . . . . . . . . . . . . . . . . . . . . 20
OWNER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . 21
SEAWATER SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . 21
FRESH WATER ILTER F AND Y STRAINER . . . . . . . . . . 21
EVAPORATOR CLEANING . . . . . . . . . . . . . . . . . . . . . . 21
A UGER MOTOR AND GEARBOX . . . . . . . . . . . . . . . . . 21
COMPRESSOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
REFRIGERANT GAS . . . . . . . . . . . . . . . . . . . . . . . . . . 22
WATER RESERVOIR . . . . . . . . . . . . . . . . . . . . . . . . . 22
FEEDWATER FILTER AND Y STRAINER . . . . . . . . . . . . 22
WINTERIZING THE SYSTEM . . . . . . . . . . . . . . . . . . . . 22
TROUBLESHOOTING GUIDE . . . . . . . . . . . . . . . . . . . 22
TECHNICAL ASSISTANCE . . . . . . . . . . . . . . . . . . . . . 23
LIMITED WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . 23
DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
SYSTEM CONNECTION . . . . . . . . . . . . . . . . . . . . . . . 24
ELECTRICAL WIRING FOR 115V 60 HZ MODELS . . . . 25
ELECTRICAL WIRING FOR 230V 60 HZ MODELS &
220V 50 HZ MODELS . . . . . . . . . . . . . . . . . . . . . . . . 26
Eskimo Ice Installation & Operation Manual INTRODUCTION
L-3040 ENGLISH 1
INTRODUCTION
This manual provides installation and operation information for the EI540D self-contained Eskimo Ice System using digital
controls (software level C-19).
The ice produced by this system is not potable and should not be ingested. Do not eat, chew, suck, swallow, or put the ice
into drinks. The ice produced by this system is intended solely for the refrigeration purposes of freshly caught fish stored in a
fish box.
WARNINGS AND NOTICES
DANGER
This equipment is not ignition protected per CFR 183.410 and may not be installed in areas that may be
exposed to flammable gas.
DANGER
The equipment referenced in this manual operates on 115 or 230 volts AC. Such voltages can be lethal,
therefore proper care must be taking during installation, operation, and servicing to prevent injury or loss
of life.
DANGER
The equipment referenced in this manual operates with compressed refrigerant at high pressures. Proper
care must be taken during installation, operation, and servicing to prevent injury or loss of life due to
improper procedures.
WARNING
Never install the unit in the bow of a boat. It must be installed on the transom, in the aft, or in a machinery
space that does not require ignition protection that is as far aft of midship as possible.
WARNING
This manual contains essential safety information concerning the safe and proper installation, operation,
and maintenance of your ice making system. It is very important that you read and understand the
contents of this manual thoroughly before installing or using the equipment. You should keep this manual
on your boat for future reference. Failure to follow Dometic approved installation, start-up, operation, and
troubleshooting procedures will void the warranty. If there are any statements in this manual that you do
not understand, refer to the back cover of this manual for technical support options.
WARNING
The ice produced by this system is not potable and should not be ingested. Do not eat, chew, suck,
swallow, or put the ice into drinks. The ice produced by this system is intended solely for the refrigeration
purposes of freshly caught fish stored in a fish box.
NOTICE
Some equipment may be shipped with specific installation sheets or wiring diagrams that may supercede
the information located in this manual. Dometic reserves the right to update or change any information
located herein at any time and without prior notice.
NOTICE
Your ice-making system uses the environmentally safe refrigerant R-404A. Federal law forbids the
intentional release of any refrigerant gas into the environment. Make certain that any field service is
performed by a specialist with the proper equipment to prevent loss of refrigerant during servicing.


Product specificaties

Merk: Dometic
Categorie: Koelkast
Model: EI540

Heb je hulp nodig?

Als je hulp nodig hebt met Dometic EI540 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Koelkast Dometic

Handleiding Koelkast