Datalogic QuickScan QS1000 Handleiding

Datalogic Barcode lezer   QuickScan QS1000

Lees hieronder de 📖 handleiding in het Nederlandse voor Datalogic QuickScan QS1000 (2 pagina's) in de categorie Barcode lezer  . Deze handleiding was nuttig voor 50 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
Laser CautionsNomenclature/Labeling
Figure 6
Class II
1. LASER RADIATION — DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
1. LASERSTRAHLUNG — NICHT IN DEN STRAHL BLICKEN
LASER KLASSE 2
1. VARO! LASERSĂ„TEILYA Ă„LĂ„ TUIJOTA SĂ„TEESEEN
LUOKAN 2 LASERLAITE
1. RAYONNEMENT LASER — NE PAS REGARDER DANS LE
FAISCEAU APPAREIL A’ LASER DE CLASSE 2
1. LUZ LASER — ¡NO MIRE HACIA EL RAYO! CATEGORIA 2
PRODUCTO LASER
1. LUZ DE LASER
NAO OCHE NO RAIO CATEGORIA 2 PRODUTO LASER
1. RADIAZIONE LASER — NON FISSARE IL FASCIO
APPARECCHIO LASER DI CLASSE 2
1. VARNING — LASERSTRÅLNING
STIRRA IJ IN I STRÅLEN — KLASS 2 LASER APPARAT
1. ADVARSEL — LASERSTRÅLING IKKE STIRR INN I STRÅLEN
— LASER KLASSE 2 PRODUKT
1. ADVARSEL — LASERSTRÅLING — SE IKKE IND I STRÅLEN
— KLASS 2 LASER PRODUKT
QuickScan 1000
is certified in the U.S. to conform to the
requirements of DHHS/CDRH 21CFR Subchapter J for Class II
laser products.
QuickScan 1000
scanners are also certified as
Class 2 laser products to the requirements of IEC 825-1:1993.
Class 2 and Class II products are not considered to be hazardous.
The
QuickScan 1000
contains internally a Visible Laser Diode
(VLD) at a wavelength of 650-670 nanometers. The scanner is
designed so that there can be no human access to harmful levels
of laser light during normal operation, user maintenance, or during
prescribed service operations.
CAUTION
Do not attempt to open or otherwise service any components in
the optics cavity. Opening or servicing any part of the optics
cavity by unauthorized personnel may violate laser safety
regulations. The optics system is a factory only repair item.
Asia Pacific
PSC Hong Kong
Hong Kong
Telephone: [852]-2-584-6210
Fax: [852]-2-521-0291
Australia
PSC Asia Pacific Pty Ltd.
North Ryde, Australia
Telephone: [61] 0 (2) 9878 8999
Fax: [61] 0 (2) 9878 8688
France
PSC S.A.R.L.
LES ULIS Cedex, France
Telephone: [33].01.64.86.71.00
Fax: [33].01.64 46.72.44
Germany
PSC GmbH
Darmstadt, Germany
Telephone: 49 (0) 61 51/93 58-0
Fax: 49 (0) 61 51/93 58 58
User's Guide
Handheld Barcode Scanner
Italy
PSC S.p.A.
Vimercate (MI), Italy
Telephone: [39] (0) 39/62903.1
Fax: [39] (0) 39/6859496
Japan
PSC Japan K.K.
Shinagawa-ku, Tokyo, Japan
Telephone: 81 (0)3 3491 6761
Fax: 81 (0)3 3491 6656
Latin America
PSC S.A., INC.
Miami, Florida, USA
Telephone: (305) 539-0111
Fax: (305) 539-0206
United Kingdom
PSC Bar Code Ltd.
Watford, England
Telephone: 44 (0) 1923 809500
Fax: 44 (0) 1923 809 505
PSC Inc.
959 Terry Street
Eugene, OR
Telephone: (541) 683-5700
Fax: (541) 345-7140
www.pscnet.com
© 2004 PSC
R44-2017 (Rev. D)
03/04
R44-2017
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Power Supply
Unit requires either a Listed Class 2 or Listed LPS power source
which supplies power directly to the scanner.
FCC
This illustration shows label placement ONLY.
For actual regulatory, patent and other application
information, view the labels on the products itself,
or call your nearest sales or service office.
Scan Window LED
Cable
Release Hole
Installation
How to Scan
Reference Figure 3 and follow these tips to get the best scanning results:
1. The scanner must be pointed at a slight angle in relation to the
bar code (Not perpendicular to the bar code.)
2. The laser beam must cross the entire bar code. (The scanner
cannot correctly read a bar code if the entire bar code is not
scanned.)
Figure 3
Troubleshooting
If the scanner is not operating properly, the following checks should be
performed: Reference Figures 4 and 5.
1. Since the scanner can receive its power from the host computer
(Power Off the Terminal—P.O.T.) or an external power supply, it
will not operate without the system power on (Figure 4a) or if the
external power supply has failed.
2. Check that the bar code labels are of sufficient quality to be
recognized by the scanner (Figure 4b). Wrinkled, smudged, or
torn bar codes can cause the scanner to not read at all. If you
suspect that label quality is a problem, scan a known good bar
code to check the scanner's read operation. Is the scanner
programmed to read the bar code symbology desired? Consult the
QuickScan 1000™ Scanner Programming Guide (P/N R44-2018)
for more information (Figure 4c).*
3. Ensure that the scanner's interface type is compatible with the host
terminal by consulting your POS system manual and/or the
QuickScan 1000 Scanner Programming Guide (P/N R44-2018).
4. Verify that the interface (I/F) cable is securely attached to the
scanner handle (Figure 4d). If you need to disconnect/reconnect
the I/F cable from the scanner, insert the tip of a paper clip into the
cable release hole shown in Figure 5. Push the clip in to depress
the connector latch and release the cable. To reconnect the cable,
orient the cable with its connector inside the scanner handle and
press it in firmly to seat and latch securely in place.
5. Verify that the interface) cable is securely attached to the host
(Figure 4e). Consult your technical support manager or refer to
your host system manual to verify the proper connection for the
scanner.
6. If an external power supply is used, exchange the power supply
with a known good power supply (Figure 4g).
If the scanner receives power from the host (P.O.T.), connect the
scanner to a known good host.
If the scanner still does not function properly, contact your local supplier
or PSC Customer Support Services.
1-(800)-547-2507 (US only) or
(541) 683-5700 (outside US)
* This Programming Guide is available on the
internet at www.pscnet.com.
CE Declaration of Conformity
PSC hereby declares that the equipment specified below has been
tested and found compliant to the following Directives and
Standards:
Directives: EMC 89/336/EEC
Low Voltage 73/23/EEC
Standards: EN55022-B EN60825
EN50082-1 EN60950
Equipment Type:Bar code Scanning Equipment
Products: Model QuickScan 1000™
Brad West
Vice President
Quality and Process
Management
PSC, Inc.
959 Terry Street
Eugene, OR 97402
U.S.A.
Peter Lomax
Vice President
Europe, Middle East & Africa
PSC Bar Code Ltd.
Axis 3, Rhodes Way
Watford
Hertfordshire WD24 4TR
UK
Figure 4
Figure 1
TROUBLESHOOTING - CONT.
Figure 5
Installation - cont.
Figure 2
Refer to Figures 1 and 2, and follow these steps to install the scanner:
1. Turn the host power off (consult the manual for your host
terminal power-off procedures). See Figure 2a.
2. Connect the interface (I/F) cable to the proper port on the Host
terminal (Figure 2b).
If your scanner will receive Power Off the Terminal, skip to step 5.
3. Connect the power cord from the AC/DC adapter at the I/F
connector (Figure 2c).
4. Connect the AC/DC adapter at the wall outlet (Figure 2d).
5. Turn host power on. (Consult the manual for your host
terminal for power-on procedures.)
6. Verify operation--point the laser spot at a sample bar code to
scan it and confirm that the scanner reads by beeping and/or
sending the data to the host terminal.
7. If your installation includes a QS1000™ scanner stand and you
wish to attach it to a countertop, unscrew the gooseneck/cradle
assembly from the base as shown in Figure 1a. Secure the
mount plate to the counter with four screws, then reassemble
the stand in place. The scanner rests in the cradle as shown in
Figure 1b.
When the scanner is powered on, its LaserSense™ feature
automatically detects when you move a bar code label into
range and clearly shows you where the bar code should be
placed by projecting a laser marker spot.


Product specificaties

Merk: Datalogic
Categorie: Barcode lezer  
Model: QuickScan QS1000

Heb je hulp nodig?

Als je hulp nodig hebt met Datalogic QuickScan QS1000 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Barcode lezer   Datalogic

Handleiding Barcode lezer  

Nieuwste handleidingen voor Barcode lezer Â